1.
Catheter Cardiovasc Interv ; 88(4): 582-589, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27218805

RESUMO

OBJECTIVE: This study's objective was to evaluate insertion techniques and device fit of the pediatric version of the Impella ventricular assist device in swine which had similar sized carotids and left ventricles (LVs) as children weighing 10-20 kg. BACKGROUND: Options for minimally invasive circulatory support in children are limited. A modified device based on the current Impella 2.5 platform was created in an effort to provide minimally invasive circulatory support for children. METHODS: Animal studies (n = 10) were performed to determine technical feasibility of device implant via the right common carotid artery (RCCA) in swine with a carotid and LV size similar to children with a BSA < 1 m2 and weight 10-20 kg. The RCCA diameter was measured on pre-implant ultrasound and the LV length was measured at necropsy. The animals were supported for 4 hr and the device explanted. Blood samples and post-explant necropsy was performed to evaluate for device related complications. RESULTS: All animals underwent successful device insertion. Mean carotid artery diameter by ultrasound was 3.5 ± 0.3 mm. There was no LV or aortic/mitral valve damage with a minimum LV length of 5.4 cm. CONCLUSIONS: Minimally invasive circulatory support is needed in small children. Limitations are primarily related to vessel and chamber size. The Impella Pediatric catheter was safely and successfully implanted in carotid arteries similar in size to children weighing 10-20 kg with minimal complications. © 2016 Wiley Periodicals, Inc.


Assuntos
Ventrículos do Coração/anatomia & histologia , Coração Auxiliar , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Animais , Superfície Corporal , Peso Corporal , Artéria Carótida Primitiva/anatomia & histologia , Artéria Carótida Primitiva/diagnóstico por imagem , Remoção de Dispositivo , Estudos de Viabilidade , Teste de Materiais , Miniaturização , Modelos Animais , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Suínos , Fatores de Tempo
2.
J Biomed Mater Res A ; 103(5): 1761-70, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25196819

RESUMO

A novel double opposed helical poly-l-lactic acid (PLLA) bioresorbable stent has been designed for use in pediatrics. The aim was to test the PLLA stent biocompatibility. The PLLA stent was immersed into whole pig's blood in a closed loop circuit then fibrin and platelet association was assessed via enzyme-linked immunosorbent assay. D-Dimer was valued at 0.2 ± 0.002 ng/mL and P-selectin 0.43 ± 00.01 ng/mL indicating limited association of fibrin and platelets on the stent. To improve biocompatibility by targeting inflammatory cells, dexamethasone was incorporated on PLLA fibers with two coating methods. Both coatings were poly(l-lactide-co-glycolide) acid (PLGA) but one was made porous with sucrose while the other remained nonporous. There was no change in mechanical properties of the fiber with either coating of PLGA polymer. The total amount of dexamethasone released was then determined for each coating. The cumulative drug release for the porous fiber was significantly higher (∼100%) over 8 weeks than the nonporous fiber (40%). Surface examination of the fiber with scanning electron microscopy showed more surface microfracturing in coatings that contain pores. The biocompatibility of this novel stent was demonstrated. Mechanical properties of the fiber were not altered by coating with PLGA polymer. Anti-inflammatory drug release was optimized using a porous PLGA polymer.


Assuntos
Implantes Absorvíveis , Materiais Revestidos Biocompatíveis/química , Liberação Controlada de Fármacos , Stents Farmacológicos , Cardiopatias Congênitas/tratamento farmacológico , Animais , Dexametasona/farmacologia , Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Ácido Láctico/química , Teste de Materiais , Selectina-P/metabolismo , Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Porosidade , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Sus scrofa