1.
Thorac Cardiovasc Surg ; 72(S 03): e1-e6, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38688313

RESUMO

BACKGROUND: In patients with tetralogy of Fallot (ToF) or ToF-like anatomy, factors possibly impacting the longevity of biological valves in the pulmonary position were investigated. METHOD: Between 1997 and 2017, 79 consecutive hospital survivors with a median age of 8.7 years (range: 0.2-56.1 years; interquartile range [IQR]: 14.8 years) with ToF or ToF-like anatomy underwent surgical implantation of Contegra (n = 34), Hancock (n = 23), Perimount (n = 9), pulmonary homograft (n = 9), and miscellaneous (n = 4) conduits. The median internal graft diameter was 19 mm (range: 11-29 mm; IQR: 8 mm) which refers to a median z-score of 0.6 standard deviation (SD) (range: -1.8 to 4.0 SD; IQR: 2.1 SD). RESULTS: The median time of follow-up was 9.4 years (range: 1.1-18.8 years; IQR: 6.0 years). Thirty-nine patients (49%) underwent surgical (n = 32) or interventional (n = 7) pulmonary valve re-replacement. Univariate Cox regression revealed patient age (p = 0.018), body surface area (p = 0.004), internal valve diameter (p = 0.005), and prosthesis z-score (p = 0.018) to impact valve longevity. Multivariate Cox regression analysis, however, did not show any significant effect (likely related to multicollinearity). Subgroup analysis showed that valve-revised patients have a higher average z-score (p = 0.003) and younger average age (p = 0.007). CONCLUSION: A decreased longevity of biological valves in the pulmonary position is related to younger age, lower valve diameter, and higher z-score. Because valve size (diameter and z-score) can be predicted by age, patient age is the crucial parameter influencing graft longevity.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Pulmonar , Tetralogia de Fallot , Humanos , Valva Pulmonar/cirurgia , Valva Pulmonar/fisiopatologia , Valva Pulmonar/diagnóstico por imagem , Masculino , Feminino , Adulto , Adulto Jovem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Fatores de Tempo , Pessoa de Meia-Idade , Adolescente , Lactente , Fatores de Risco , Resultado do Tratamento , Criança , Pré-Escolar , Tetralogia de Fallot/cirurgia , Tetralogia de Fallot/fisiopatologia , Estudos Retrospectivos , Fatores Etários , Falha de Prótese , Medição de Risco , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...