Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Forensic Sci ; 69(3): 888-904, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38528830

RESUMO

There are many factors that may affect the longevity of or guide the use of canine training aids. Literature to date has mainly focused on identifying the headspace volatiles associated with training aids or odors and only minimal research exists into how different variables may alter those volatiles. The current study examines several factors affecting canine training aids: humidity, air flow, transportation, and operational deployment, using the triacetone triperoxide polymer odor capture-and-release canine training aid (TATP POCR) as the target. The TATP POCR is an absorption-based canine training aid developed to be used to safely train canines to detect the odor of the explosive TATP in operational settings. Comparisons of the TATP POCR to neat TATP are made throughout the manuscript. First, humidity increased the background components of the POCR matrix, as well as the amount of TATP recovered was above the POCR. Humidity thus affected the amount of TATP detected but did not prevent detection. Second, air flow lessened the lifetime of the TATP POCR. Third, the practice of using primary and secondary containment successfully prevented contamination, cross-contamination, and significant target loss, thereby maintaining kit integrity. Finally, the absorption of background odors from training environments was not observed. TATP headspace concentrations between a Deployed and Control POCR kit were not significantly different at time 0 (i.e., upon opening), which suggests that the operational use does not affect the function of the TATP POCR system. This information provides pivotal evidence for explosives detection canine handlers or trainers who utilize the TATP POCR.


Assuntos
Umidade , Odorantes , Cães , Animais , Compostos Heterocíclicos com 1 Anel , Peróxidos/análise , Movimentos do Ar , Polímeros , Substâncias Explosivas
2.
J Forensic Sci ; 68(5): 1816-1824, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37485643

RESUMO

In the past, pattern disciplines within forensic science have periodically faced criticism due to their subjective and qualitative nature and the perceived absence of research evaluating and supporting the foundations of their practices. Recently, however, forensic scientists and researchers in the field of pattern evidence analysis have developed and published approaches that are more quantitative, objective, and data driven. This effort includes automation, algorithms, and measurement sciences, with the end goal of enabling conclusions to be informed by quantitative models. Before employing these tools, forensic evidence must be digitized in a way that adequately balances high-quality detail and content capture with minimal background noise imparted by the selected technique. While the current work describes the process of optimizing a method to digitize physical documentary evidence for use in semi-automated trash mark examinations, it could be applied to assist other disciplines where the digitization of physical items of evidence is prevalent. For trash mark examinations specifically, it was found that high-resolution photography provided optimal digital versions of evidentiary items when compared to high-resolution scanning.

3.
J Forensic Sci ; 68(3): 898-907, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36991527

RESUMO

Contamination of canine training aids is a pervasive issue that may lead to incorrect canine discrimination of target odors. It is therefore important to properly store training materials to maintain their integrity and efficiency. First, this study demonstrated the potential for contamination using GloGerm™ as a proxy for odor/particulate transfer. Then, eight types of containers were evaluated to determine (1) the ability to prevent odor permeation and (2) the likelihood of maintaining the ab/adsorbed odor. Lastly, a longitudinal study evaluated how the permeation of the target odor changed over time. Analysis occurred using a direct analysis in real-time mass spectrometer (DART-MS) to detect triacetone triperoxide (TATP) from the non-hazardous canine training aid known as the polymer odor capture-and-release (POCR) system. Results showed that Mylar and Opsak bags were most effective for short-term storage, maintaining low levels of ab/adsorption. Over time, the amount of TATP permeating through the primary containers and collecting in a secondary container (i.e., outer packaging) increased at 1 week and decreased thereafter (up to 4 months). The amount of TATP collecting in the primary containers, however, increased up to 1 month and decreased thereafter.


Assuntos
Compostos Heterocíclicos com 1 Anel , Peróxidos , Animais , Cães , Estudos Longitudinais , Espectrometria de Massas , Compostos Heterocíclicos com 1 Anel/análise , Peróxidos/análise
4.
J Forensic Sci ; 67(6): 2308-2320, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35968683

RESUMO

It is generally accepted in the canine detection industry that a barrier (such as a glove) should be used between a human and evidence or canine training aids in order to prevent contamination and cross-contamination as well as protect the handler from hazardous materials. However, no studies exist evaluating this assumption. Further, there is no published literature examining the different types of gloves for their utility in handling evidence or training materials used in canine detection work. This study was the first of its kind to address these gaps in the literature. First, GloGerm™ was used as a proxy for human scent and odor(s)/particulate(s) to visualize potential contamination. Then, three types of gloves (nitrile, two layers of nitrile, latex, and polyethylene) were tested for the permeation of human scent using furfural as a proof of concept, followed by pooled human sweat. Finally, the inherent odor of each glove type was identified. Two analytical techniques were used simultaneously as static and standoff dynamic detection systems, respectively: solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) and direct analysis in real time-mass spectrometry (DART-MS). Using a double layer of nitrile gloves was the most effective in preventing furfural permeation from the analytical standard, while a single layer of nitrile prevented furfural from permeating from human sweat up to 2 h. Polyethylene gloves allowed the highest amount of furfural permeation but had no inherent odor detected. Headspace analysis detected two compounds for nitrile gloves and four compounds for latex gloves, but the nitrile compounds had a higher relative abundance.


Assuntos
Látex , Odorantes , Humanos , Cães , Animais , Furaldeído , Nitrilas , Polietilenos
5.
Forensic Sci Int ; 335: 111291, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35429779

RESUMO

Trash marks are unintentional markings observed on printed, scanned, or photocopied documents that result from permanent defects or transient material in office machines and can be used for source attribution of questioned documents. Trash mark examinations have been in use in forensic laboratories for decades, yet the method remains relatively untested and relies on training, experience, and anecdotal information to support its validity. This study generated and harnessed objective data to empirically test one of the foundational theories for assessing the origin of photocopied documents: provided trash marks are present in sufficient quantity and/or quality, no two machines will exhibit a constellation of trash marks that is indistinguishable from another. In this project, objective trash mark location and size data was generated for 50 known photocopiers using both a traditional and a novel, automated method. Inter-machine comparisons were conducted using a novel variant of the Hausdorff distance algorithm to generate a quantitative assessment of how similar or different the 2450 pairs of trash mark constellations were from one another. This study found that each of the machines bearing one or more trash marks exhibited objective differences in their trash mark constellations, ultimately providing support for the tested hypothesis.


Assuntos
Algoritmos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...