1.
PLoS One ; 10(6): e0130906, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26103002

RESUMO

Posterior leaflet prolapse following chordal elongation or rupture is one of the primary valvular diseases in patients with degenerative mitral valves (MVs). Quadrangular resection followed by ring annuloplasty is a reliable and reproducible surgical repair technique for treatment of posterior leaflet prolapse. Virtual MV repair simulation of leaflet resection in association with patient-specific 3D echocardiographic data can provide quantitative biomechanical and physiologic characteristics of pre- and post-resection MV function. We have developed a solid personalized computational simulation protocol to perform virtual MV repair using standard clinical guidelines of posterior leaflet resection with annuloplasty ring implantation. A virtual MV model was created using 3D echocardiographic data of a patient with posterior chordal rupture and severe mitral regurgitation. A quadrangle-shaped leaflet portion in the prolapsed posterior leaflet was removed, and virtual plication and suturing were performed. An annuloplasty ring of proper size was reconstructed and virtual ring annuloplasty was performed by superimposing the ring and the mitral annulus. Following the quadrangular resection and ring annuloplasty simulations, patient-specific annular motion and physiologic transvalvular pressure gradient were implemented and dynamic finite element simulation of MV function was performed. The pre-resection MV demonstrated a substantial lack of leaflet coaptation which directly correlated with the severe mitral regurgitation. Excessive stress concentration was found along the free marginal edge of the posterior leaflet involving the chordal rupture. Following the virtual resection and ring annuloplasty, the severity of the posterior leaflet prolapse markedly decreased. Excessive stress concentration disappeared over both anterior and posterior leaflets, and complete leaflet coaptation was effectively restored. This novel personalized virtual MV repair strategy has great potential to help with preoperative selection of the patient-specific optimal MV repair techniques, allow innovative surgical planning to expect improved efficacy of MV repair with more predictable outcomes, and ultimately provide more effective medical care for the patient.


Assuntos
Simulação por Computador , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Prolapso da Valva Mitral/patologia , Medicina de Precisão , Desenho de Prótese/métodos , Cirurgia Assistida por Computador , Interface Usuário-Computador , Cordas Tendinosas/patologia , Cordas Tendinosas/cirurgia , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Ruptura Espontânea , Estresse Mecânico
2.
Ultrasound Med Biol ; 41(6): 1701-10, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25819469

RESUMO

The aim of this study was to determine whether pre-treatment with nitric oxide-loaded echogenic liposomes (NO-ELIP) plus ultrasound can improve highlighting by molecularly targeted (anti-vascular cell adhesion molecule 1 [VCAM-1]) ELIP of atheroma components. Atherosclerotic animals were treated with anti-VCAM-1-ELIP or immunoglobulin (IgG)-ELIP. Each group was selected at random to receive pre-treatment with standard ELIP plus ultrasound, NO-ELIP without ultrasound and NO-ELIP plus ultrasound. Intravascular ultrasound highlighting data for the same arterial segments were collected before and after treatment. Pre-treatment with NO-ELIP plus ultrasound resulted in a significant increase in acoustic enhancement by anti-VCAM-1-ELIP (21.3 ± 1.5% for gray-scale value, 53.9 ± 3.1% for radiofrequency data; p < 0.001 vs. IgG-ELIP, p < 0.05 vs. pre-treatment with standard ELIP plus ultrasound or NO-ELIP without ultrasound). NO-ELIP plus ultrasound can improve highlighting of atheroma by anti-VCAM-1 ELIP. This NO pre-treatment strategy may be useful in optimizing contrast agent delivery to the vascular wall for both diagnostic and therapeutic applications.


Assuntos
Lipossomos/metabolismo , Imagem Molecular/métodos , Óxido Nítrico/metabolismo , Placa Aterosclerótica/diagnóstico por imagem , Molécula 1 de Adesão de Célula Vascular/metabolismo , Animais , Modelos Animais de Doenças , Placa Aterosclerótica/metabolismo , Suínos , Porco Miniatura , Ultrassonografia
3.
J Med Biol Eng ; 35(1): 104-112, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25750606

RESUMO

Parachute mitral valves (PMVs) and parachute-like asymmetric mitral valves (PLAMVs) are associated with congenital anomalies of the papillary muscles. Current imaging modalities cannot provide detailed biomechanical information. This study describes computational evaluation techniques based on three-dimensional (3D) echocardiographic data to determine the biomechanical and physiologic characteristics of PMVs and PLAMVs. The closing and opening mechanics of a normal mitral valve (MV), two types of PLAMV with different degrees of asymmetry, and a true PMV were investigated. MV geometric data in a patient with a normal MV was acquired from 3D echocardiography. The pathologic MVs were modeled by altering the configuration of the papillary muscles in the normal MV model. Dynamic finite element simulations of the normal MV, PLAMVs, and true PMV were performed. There was a strong correlation between the reduction of mitral orifice size and the degree of asymmetry of the papillary muscle location. The PLAMVs demonstrated decreased leaflet coaptation and tenting height. The true PMV revealed severely wrinkled leaflet deformation and narrowed interchordal spaces, leading to uneven leaflet coaptation. There were considerable decreases in leaflet coaptation and abnormal leaflet deformation corresponding to the anomalous location of the papillary muscle tips. This computational MV evaluation strategy provides a powerful tool to better understand biomechanical and pathophysiologic MV abnormalities.

5.
Echocardiography ; 31(10): E300-3, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25109487

RESUMO

Clinical long-term outcomes have shown that partial leaflet resection followed by ring annuloplasty is a reliable and reproducible surgical repair technique for treatment of mitral valve (MV) leaflet prolapse. We report a 61-year-old male for three-dimensional transesophageal echocardiography (3DTEE)-based virtual posterior leaflet resection and ring annuloplasty. Severe mitral regurgitation was found and computational evaluation demonstrated substantial leaflet malcoaptation and high stress concentration. Following virtual resection and ring annuloplasty, posterior leaflet prolapse markedly decreased, sufficient leaflet coaptation was restored, and high stress concentration disappeared. Virtual MV repair strategies using 3DTEE have the potential to help optimize MV repair.


Assuntos
Ecocardiografia Tridimensional , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos , Interface Usuário-Computador , Ecocardiografia Transesofagiana/métodos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/cirurgia , Valor Preditivo dos Testes , Resultado do Tratamento
6.
Biomed Eng Online ; 13(1): 31, 2014 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-24649999

RESUMO

BACKGROUND: Computational simulation using numerical analysis methods can help to assess the complex biomechanical and functional characteristics of the mitral valve (MV) apparatus. It is important to correctly determine physical contact interaction between the MV apparatus components during computational MV evaluation. We hypothesize that leaflet-to-chordae contact interaction plays an important role in computational MV evaluation, specifically in quantitating the degree of leaflet coaptation directly related to the severity of mitral regurgitation (MR). In this study, we have performed dynamic finite element simulations of MV function with and without leaflet-to-chordae contact interaction, and determined the effect of leaflet-to-chordae contact interaction on the computational MV evaluation. METHODS: Computational virtual MV models were created using the MV geometric data in a patient with normal MV without MR and another with pathologic MV with MR obtained from 3D echocardiography. Computational MV simulation with full contact interaction was specified to incorporate entire physically available contact interactions between the leaflets and chordae tendineae. Computational MV simulation without leaflet-to-chordae contact interaction was specified by defining the anterior and posterior leaflets as the only contact inclusion. RESULTS: Without leaflet-to-chordae contact interaction, the computational MV simulations demonstrated physically unrealistic contact interactions between the leaflets and chordae. With leaflet-to-chordae contact interaction, the anterior marginal chordae retained the proper contact with the posterior leaflet during the entire systole. The size of the non-contact region in the simulation with leaflet-to-chordae contact interaction was much larger than for the simulation with only leaflet-to-leaflet contact. CONCLUSIONS: We have successfully demonstrated the effect of leaflet-to-chordae contact interaction on determining leaflet coaptation in computational dynamic MV evaluation. We found that physically realistic contact interactions between the leaflets and chordae should be considered to accurately quantitate leaflet coaptation for MV simulation. Computational evaluation of MV function that allows precise quantitation of leaflet coaptation has great potential to better quantitate the severity of MR.


Assuntos
Cordas Tendinosas/patologia , Insuficiência da Valva Mitral/patologia , Valva Mitral/patologia , Algoritmos , Engenharia Biomédica/métodos , Simulação por Computador , Eletrocardiografia/métodos , Humanos , Imageamento Tridimensional , Insuficiência da Valva Mitral/terapia , Modelos Anatômicos , Software , Estresse Mecânico
7.
Biomed Mater Eng ; 24(1): 7-13, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211876

RESUMO

Ischemic mitral valve (MV) is a common complication of pathologic remodeling of the left ventricle due to acute and chronic coronary artery diseases. It frequently represents the pathologic consequences of increased tethering forces and reduced coaptation of the MV leaflets. Ischemic MV function has been investigated from a biomechanical perspective using finite element-based computational MV evaluation techniques. A virtual 3D MV model was created utilizing 3D echocardiographic data in a patient with normal MV. Two types of ischemic MVs containing asymmetric medial-dominant or symmetric leaflet tenting were modeled by altering the configuration of the normal papillary muscle (PM) locations. Computational simulations of MV function were performed using dynamic finite element methods, and biomechanical information across the MV apparatus was evaluated. The ischemic MV with medial-dominant leaflet tenting demonstrated distinct large stress distributions in the posteromedial commissural region due to the medial PM displacement toward the apical-medial direction resulting in a lack of leaflet coaptation. In the ischemic MV with balanced leaflet tenting, mitral incompetency with incomplete leaflet coaptation was clearly identified all around the paracommissural regions. This computational MV evaluation strategy has the potential for improving diagnosis of ischemic mitral regurgitation and treatment of ischemic MVs.


Assuntos
Cardiomiopatias/fisiopatologia , Valva Mitral/fisiopatologia , Isquemia Miocárdica/patologia , Fenômenos Biomecânicos , Simulação por Computador , Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Insuficiência da Valva Mitral/fisiopatologia , Músculos Papilares/fisiopatologia , Estresse Mecânico
8.
Biomed Mater Eng ; 24(1): 61-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211883

RESUMO

Breast cancer is the most common type of cancer occurring among women in the United States. Nitric oxide (NO) is endogenous signaling molecules that regulate biological processes. NO has the potential to induce either cancer progression or cancer cell apoptosis depending on intra-tumoral NO concentration. High levels of NO have a cytotoxic effect on cancer cells. A novel cytotoxic gas delivery system has been developed using NO-loaded echogenic liposomes (ELIP) for breast cancer treatment. Empty ELIP and NO-ELIP were prepared using the previously developed freezing-under-pressure method with modified lipid composition. Echogenicity of NO-ELIP was measured to determine the stability of NO-ELIP. Two types of breast cancer cell (BCC) lines, MDA-MB-231 and MDA-MB-468, were utilized. MTT assay was performed after NO-ELIP treatment to determine BCC viability. Echogenicity data demonstrated improved stability of NO-ELIP with the use of BSA for resuspension of NO-ELIP. Cell death induced by NO-ELIP was not from lipid cytotoxicity but from NO. The cytotoxic effect of NO-ELIP on BCC was highly dependent on NO-ELIP concentration. NO-ELIP in concentration of 1.0-2.0 mg/ml induced dramatically decreased BCC viability. This novel cytotoxic gas delivery nanomedicine using liposomal carriers, NO-ELIP, has the potential to provide improved therapeutic effect for breast cancer treatment.


Assuntos
Neoplasias da Mama/terapia , Lipossomos/química , Nanopartículas/química , Óxido Nítrico/administração & dosagem , Antineoplásicos/administração & dosagem , Apoptose , Neoplasias da Mama/patologia , Linhagem Celular Tumoral , Sobrevivência Celular , Relação Dose-Resposta a Droga , Sistemas de Liberação de Medicamentos , Ensaios de Seleção de Medicamentos Antitumorais , Feminino , Humanos , Concentração Inibidora 50 , Lipídeos/química , Manitol/química , Óxido Nítrico/química , Pressão , Transdução de Sinais , Sais de Tetrazólio , Tiazóis , Fatores de Tempo
9.
Biomed Mater Eng ; 24(1): 341-7, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24211915

RESUMO

Alterations of normal mitral valve (MV) function lead to mitral insufficiency, i.e., mitral regurgitation (MR). Mitral repair is the most popular and most efficient surgical intervention for MR treatment. An annuloplasty ring is implanted following complex reconstructive MV repairs to prevent potential reoccurrence of MR. We have developed a novel finite element (FE)-based simulation protocol to perform patient-specific virtual ring annuloplasty following the standard clinical guideline procedure. A virtual MV was created using 3D echocardiographic data in a patient with mitral annular dilation. Proper type and size of the ring were determined in consideration of the MV apparatus geometry. The ring was positioned over the patient MV model and annuloplasty was simulated. Dynamic simulation of MV function across the complete cardiac cycle was performed. Virtual patient-specific annuloplasty simulation well demonstrated morphologic information of the MV apparatus before and after ring implantation. Dynamic simulation of MV function following ring annuloplasty demonstrated markedly reduced stress distribution across the MV leaflets and annulus as well as restored leaflet coaptation compared to pre-annuloplasty. This novel FE-based patient-specific MV repair simulation technique provides quantitative information of functional improvement following ring annuloplasty. Virtual MV repair strategy may effectively evaluate and predict interventional treatment for MV pathology.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Análise de Elementos Finitos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Fenômenos Biomecânicos , Simulação por Computador , Ecocardiografia , Próteses Valvulares Cardíacas , Humanos , Imageamento Tridimensional , Valva Mitral/patologia , Modelos Cardiovasculares , Desenho de Prótese , Reprodutibilidade dos Testes , Estresse Mecânico , Técnicas de Sutura , Suturas
10.
Ann Biomed Eng ; 42(1): 139-48, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24072489

RESUMO

Mitral valve (MV) repair using expanded polytetrafluoroethylene sutures is an established and preferred interventional method to resolve the complex pathophysiologic problems associated with chordal rupture. We developed a novel computational evaluation protocol to determine the effect of the artificial sutures on restoring MV function following valve repair. A virtual MV was created using three-dimensional echocardiographic data in a patient with ruptured mitral chordae tendineae (RMCT). Virtual repairs were designed by adding artificial sutures between the papillary muscles and the posterior leaflet where the native chordae were ruptured. Dynamic finite element simulations were performed to evaluate pre- and post-repair MV function. Abnormal posterior leaflet prolapse and mitral regurgitation was clearly demonstrated in the MV with ruptured chordae. Following virtual repair to reconstruct ruptured chordae, the severity of the posterior leaflet prolapse decreased and stress concentration was markedly reduced both in the leaflet tissue and the intact native chordae. Complete leaflet coaptation was restored when four or six sutures were utilized. Computational simulations provided quantitative information of functional improvement following MV repair. This novel simulation strategy may provide a powerful tool for evaluation and prediction of interventional treatment for RMCT.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Simulação por Computador , Prolapso da Valva Mitral , Valva Mitral , Suturas , Procedimentos Cirúrgicos Cardíacos/instrumentação , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Ultrassonografia
11.
Atherosclerosis ; 231(2): 252-60, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24267236

RESUMO

OBJECTIVE: This study aimed to demonstrate whether pretreatment with nitric oxide (NO) loaded into echogenic immunoliposomes (ELIP) plus ultrasound, applied before injection of molecularly targeted ELIP can promote penetration of the targeted contrast agent and improve visualization of atheroma components. METHODS: ELIP were prepared using the pressurization-freeze method. Atherosclerosis was induced in Yucatan miniswine by balloon denudation and a hyperlipidemic diet. The animals were randomized to receive anti-intercellular adhesion molecule-1 (ICAM-1) ELIP or immunoglobulin (IgG)-ELIP, and were subdivided to receive pretreatment with standard ELIP plus ultrasound, NO-loaded ELIP, or NO-loaded ELIP plus ultrasound. Intravascular ultrasound (IVUS) data were collected before and after treatment. RESULTS: Pretreatment with standard ELIP plus ultrasound or NO-loaded ELIP without ultrasound resulted in 9.2 ± 0.7% and 9.2 ± 0.8% increase in mean gray scale values, respectively, compared to baseline (p < 0.001 vs. control). Pretreatment with NO-loaded ELIP plus ultrasound activation resulted in a further increase in highlighting with a change in mean gray scale value to 14.7 ± 1.0% compared to baseline (p < 0.001 vs. control). These differences were best appreciated when acoustic backscatter data values (RF signal) were used [22.7 ± 2.0% and 22.4 ± 2.2% increase in RF signals for pretreatment with standard ELIP plus ultrasound and NO-loaded ELIP without ultrasound respectively (p < 0.001 vs. control), and 40.0 ± 2.9% increase in RF signal for pretreatment with NO-loaded ELIP plus ultrasound (p < 0.001 vs. control)]. CONCLUSION: NO-loaded ELIP plus ultrasound activation can facilitate anti-ICAM-1 conjugated ELIP delivery to inflammatory components in the arterial wall. This NO pretreatment strategy has potential to improve targeted molecular imaging of atheroma for eventual true tailored and personalized management of cardiovascular diseases.


Assuntos
Lipossomos/química , Imagem Molecular/métodos , Óxido Nítrico/química , Placa Aterosclerótica/diagnóstico , Acústica , Animais , Hiperlipidemias , Molécula 1 de Adesão Intercelular/metabolismo , Imagem Molecular/instrumentação , Permeabilidade , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/genética , Distribuição Aleatória , Suínos , Porco Miniatura , Ultrassom , Ultrassonografia
12.
Biomed Eng Online ; 12: 39, 2013 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-23651569

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) is a standard imaging modality for identification of plaque formation in the coronary and peripheral arteries. Volumetric three-dimensional (3D) IVUS visualization provides a powerful tool to overcome the limited comprehensive information of 2D IVUS in terms of complex spatial distribution of arterial morphology and acoustic backscatter information. Conventional 3D IVUS techniques provide sub-optimal visualization of arterial morphology or lack acoustic information concerning arterial structure due in part to low quality of image data and the use of pixel-based IVUS image reconstruction algorithms. In the present study, we describe a novel volumetric 3D IVUS reconstruction algorithm to utilize IVUS signal data and a shape-based nonlinear interpolation. METHODS: We developed an algorithm to convert a series of IVUS signal data into a fully volumetric 3D visualization. Intermediary slices between original 2D IVUS slices were generated utilizing the natural cubic spline interpolation to consider the nonlinearity of both vascular structure geometry and acoustic backscatter in the arterial wall. We evaluated differences in image quality between the conventional pixel-based interpolation and the shape-based nonlinear interpolation methods using both virtual vascular phantom data and in vivo IVUS data of a porcine femoral artery. Volumetric 3D IVUS images of the arterial segment reconstructed using the two interpolation methods were compared. RESULTS: In vitro validation and in vivo comparative studies with the conventional pixel-based interpolation method demonstrated more robustness of the shape-based nonlinear interpolation algorithm in determining intermediary 2D IVUS slices. Our shape-based nonlinear interpolation demonstrated improved volumetric 3D visualization of the in vivo arterial structure and more realistic acoustic backscatter distribution compared to the conventional pixel-based interpolation method. CONCLUSIONS: This novel 3D IVUS visualization strategy has the potential to improve ultrasound imaging of vascular structure information, particularly atheroma determination. Improved volumetric 3D visualization with accurate acoustic backscatter information can help with ultrasound molecular imaging of atheroma component distribution.


Assuntos
Artérias/diagnóstico por imagem , Imageamento Tridimensional/métodos , Placa Aterosclerótica/diagnóstico por imagem , Algoritmos , Animais , Modelos Animais de Doenças , Dinâmica não Linear , Imagens de Fantasmas , Placa Aterosclerótica/diagnóstico , Reprodutibilidade dos Testes , Suínos , Ultrassonografia
14.
J Biomech ; 46(6): 1104-12, 2013 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-23433464

RESUMO

Most surgical procedures for patients with mitral regurgitation (MR) focus on optimization of annular dimension and shape utilizing ring annuloplasty to restore normal annular geometry, increase leaflet coaptation, and reduce regurgitation. Computational studies may provide insight on the effect of annular motion on mitral valve (MV) function through the incorporation of patient-specific MV apparatus geometry from clinical imaging modalities such as echocardiography. In the present study, we have developed a novel algorithm for modeling patient-specific annular motion across the cardiac cycle to further improve our virtual MV modeling and simulation strategy. The MV apparatus including the leaflets, annulus, and location of papillary muscle tips was identified using patient 3D echocardiography data at end diastole and peak systole and converted to virtual MV model. Dynamic annular motion was modeled by incorporating the ECG-gated time-varying scaled annular displacement across the cardiac cycle. We performed dynamic finite element (FE) simulation of two sets of patient data with respect to the presence of MR. Annular morphology, stress distribution across the leaflets and annulus, and contact stress distribution were determined to assess the effect of annular motion on MV function and leaflet coaptation. The effect of dynamic annular motion clearly demonstrated reduced regions with large stress values and provided an improved accuracy in determining the location of improper leaflet coaptation. This strategy has the potential to better quantitate the extent of pathologic MV and better evaluate functional restoration following MV repair.


Assuntos
Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiologia , Movimento/fisiologia , Algoritmos , Ecocardiografia Tridimensional , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...