Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Molecules ; 27(9)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35566205

RESUMO

The purpose of this study was to identify potential metabolic pathways and metabolites of OJT007, a methionine aminopeptidase 1 (MetAP1) inhibitor. OJT007 is a novel drug with potent antiproliferative effects against Leishmania Major. We conducted in vitro Phase I oxidation and Phase II glucuronidation assays on OJT007 using rat liver microsomes. Four unknown metabolites were initially identified using a UPLC-UV system from microsomal incubated samples. LC-MS/MS analysis was then used to identify the structural characteristics of these metabolites via precursor ion scan, neutral loss scan, and product ion scan. A glucuronide metabolite was further confirmed by ß-glucuronidase hydrolysis. The kinetic parameters of OJT007 glucuronidation demonstrated that OJT007 undergoes rapid metabolism. These results demonstrate the liver's microsomal ability to mediate three mono-oxidated metabolites and one mono-glucuronide metabolite. This suggests hepatic glucuronidation metabolism of OJT007 may be the cause of its poor oral bioavailability.


Assuntos
Microssomos Hepáticos , Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida , Glucuronidase/metabolismo , Glucuronídeos/farmacologia , Microssomos/metabolismo , Microssomos Hepáticos/metabolismo , Ratos
2.
Artigo em Inglês | MEDLINE | ID: mdl-33925369

RESUMO

OJT007 is a methionine aminopeptidase 1 (MetAP1) inhibitor with potent anti-proliferative effects against Leishmania Major. In order to study its pharmacokinetics as a part of the drug development process, a sensitive, specific, and reproducible ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated. Voriconazole was used as the internal standard to generate standard curves ranging from 5 to 1000 ng/mL. The separation was achieved using a UPLC system equipped with an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 µm) with 0.1% formic acid in acetonitrile and 0.1% formic acid in water as the mobile phase under gradient elution at a flow rate of 0.4 mL/min. The mass analysis was performed with a 4000 QTRAP® mass spectrometer using multiple-ion reaction monitoring (MRM) in the positive mode, with the transition of m/z 325 → m/z 205 for OJT007 and m/z 350 → m/z 101 for voriconazole. The intra- and inter-day precision and accuracy were within ±15%. The mean extraction recovery and the matrix effect were 95.1% and 7.96%, respectively, suggesting no significant matrix interfering with the quantification of the drug in rat plasma. This study was successfully used for the pharmacokinetic evaluation of OJT007 using the rat as an animal model.


Assuntos
Espectrometria de Massas em Tandem , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...