Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 40(6): 922-9, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9840838

RESUMO

The purpose of this study was to determine whether the capillary transfer constant (Ki) of gadolinium-DTPA was sensitive to perfusion changes and whether ischemic regions in the myocardium could be identified using the modified Kety formula. Ki was measured at rest and during dipyridamole-induced vasodilation in 10 healthy volunteers and in 10 patients with ischemic heart disease. Ki increased by a factor of 2.5+/-1.2 (mean +/- SD) from 55+/-16 ml 100 g(-1)min(-1) at rest to 136+/-46 ml 100 g(-1)min(-1) (P < 0.01) during vasodilation in the healthy subjects. In the patients, there were no changes in Ki during vasodilation in ischemic regions (50+/-18 versus 49+/-30 ml 100 g(-1)min(-1) (P > 0.4)). Ki increased in nonischemic regions by a factor of 2.0+/-0.8 from 44+/-17 to 81+/-32 ml 100 g(-1)min(-1) during vasodilation (P < 0.02). It is concluded that the capillary transfer constant is sensitive to perfusion changes and that regional ischemia can be detected with MRI. This noninvasive and quantitative method may prove useful in the evaluation of patients with ischemic heart disease.


Assuntos
Meios de Contraste , Gadolínio DTPA , Angiografia por Ressonância Magnética/métodos , Miocárdio/patologia , Vasodilatação , Adulto , Calibragem , Capilares/patologia , Angiografia Coronária , Dipiridamol , Humanos , Angiografia por Ressonância Magnética/instrumentação , Angiografia por Ressonância Magnética/estatística & dados numéricos , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Valores de Referência , Fatores de Tempo , Vasodilatação/efeitos dos fármacos , Vasodilatadores
2.
Magn Reson Imaging ; 16(8): 893-9, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9814771

RESUMO

The purpose of this study was to optimize an inversion-recovery (IR) turbo fast low-angle shot (FLASH) for multislice imaging by evaluating the accuracy of calculated the relaxation-rate (R1) for different inversion times (TI). This is important for tracer kinetic modeling because it requires a system responding linearly to input. R1 are linearly related to changes in the concentration of gadolinium (Gd)-diethylenetriaminepentaacetic acid (DTPA), and R1 is a parameter that can be derived from the magnetic resonance (MR) signal. The accuracy of calculated R1 using an IR turbo fast low-angle shot was evaluated in phantoms and for increasing TIs using spectroscopically measured R1 values as reference. Signal curves, obtained in vivo after a bolus injection of Gd-DTPA, were used in an analytical computer program to study the effect of different TI-values on accurate calculation of R1. Results show that TIeff should be <200 ms to measure the bolus-passage of Gd-DTPA in blood accurately, whereas the myocardial response can be measured correctly for TIeff < 870 ms at 1.5 T. The initial slope of the myocardial signal enhancement curve becomes steeper for larger TI values, whereas the calculated R1 curves were similar, indicating that these curves, rather than signal curves, are more suitable even for qualitative perfusion evaluation. It is concluded that the results can be incorporated in a multislice IR turbo fast low-angle shot using the first slice (with a short TI) for assessment of both the arterial input function and the tissue response and the second slice in another position for assessment of the tissue response alone.


Assuntos
Gadolínio DTPA , Coração/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste , Eletrocardiografia , Humanos , Imagens de Fantasmas
3.
Acta Radiol ; 37(5): 813-22, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8915299

RESUMO

PURPOSE: To investigate changes in the regional cerebral blood volume (rCBV) in human subjects during rest and hypercapnia by MR imaging, and to compare the results from contrast-enhanced and noncontrast-enhanced susceptibility-weighted imaging. MATERIAL AND METHODS: Five healthy volunteers (aged 24-29 years) were studied during inhalation of atmospheric air and 7% CO2. A bolus injection of Gd-DTPA was given during the acquisition of a series of susceptibility-weighted, fast gradient echo images (TR/TE = 27/22 ms). The images were converted to delta R2* maps, and CBV was calculated pixelwise by fitting a gamma-variate function to the data. The tissue concentration vs time curves were deconvoluted using an input function obtained by arterial sampling. RESULTS: The ratio of gray to white matter CBV (1.9-2.5) as well as the fractional increase in rCBV during hypercapnia (about 30%) was found to be in accordance with results obtained by other methods. Noncontrast functional MR (fMR) imaging showed signal increases in gray matter, but also inconsistent changes in some white matter regions. CONCLUSION: In this experiment, contrast-enhanced imaging seemed to show a somewhat higher sensitivity towards changes in cerebral hemodynamics than noncontrast-enhanced imaging. The results of the deconvolution analysis suggested that perfusion calculation by conventional tracer kinetic methods may be impracticable because of nonlinear effects in contrast-enhanced MR imaging.


Assuntos
Encéfalo/irrigação sanguínea , Dióxido de Carbono , Circulação Cerebrovascular/efeitos dos fármacos , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos , Ácido Pentético/análogos & derivados , Administração por Inalação , Adulto , Encéfalo/anatomia & histologia , Dióxido de Carbono/administração & dosagem , Circulação Cerebrovascular/fisiologia , Gadolínio DTPA , Humanos , Sensibilidade e Especificidade
4.
Early Hum Dev ; 43(1): 15-29, 1995 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-8575348

RESUMO

Twenty-eight infants with postmenstrual ages (PMA) in the range of 32-80 weeks were investigated. Twenty were newborn; among these the observed birth weight divided by the expected weight ranged from 0.31 to 1.1. Axial magnetic resonance images were recorded with a triple spin-echo sequence and the volumes were determined by encircling each structure of interest on every slice. Segmentation into grey matter, white matter and CSF was done by semi-automatic discriminant analysis. Growth charts for the cerebrum, cerebellum, corpora striata, thalami, ventricles, and grey and white matter are provided for infants with appropriate birth weight. The striatal (P = 0.02) and thalamic (P < 0.001) percentage of the hemispheric volume decreased with age, whereas the ratio of grey matter to white matter (G/W-ratio) increased (P = 0.01). In the neonatal patients, brain volumes were independently associated with both PMA and the degree of growth retardation. It was calculated that the hemispheric volume was reduced by from 16% to 23% if the total bodyweight was reduced by 40%. The G/W-ratio was found to be independently associated with the PMA (P < 0.05) and the degree of IUGR (P < 0.1) suggesting that fetal growth retardation reduces grey matter volume more than white matter.


Assuntos
Encéfalo/anatomia & histologia , Encéfalo/patologia , Retardo do Crescimento Fetal/patologia , Peso ao Nascer/fisiologia , Cerebelo/anatomia & histologia , Cerebelo/patologia , Ventrículos Cerebrais/anatomia & histologia , Ventrículos Cerebrais/patologia , Corpo Estriado/anatomia & histologia , Corpo Estriado/patologia , Retardo do Crescimento Fetal/fisiopatologia , Idade Gestacional , Humanos , Recém-Nascido , Modelos Lineares , Imageamento por Ressonância Magnética , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Tálamo/anatomia & histologia , Tálamo/patologia
5.
Magn Reson Imaging ; 11(6): 841-50, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8371639

RESUMO

Quantitative magnetic resonance imaging may offer unique potential for tissue characterization in vivo. In this connection texture analysis of quantitative MR images may be of special importance. Because evaluation of texture analysis needs large data material, multicenter approaches become mandatory. Within the frame of BME Concerted Action on Tissue Characterization by MRI and MRS, a pilot multicenter study was launched in order to evaluate the technical problems including comparability of relaxation time measurements carried out in the individual sites. Human brain, skeletal muscle, and liver were used as models. A total of 218 healthy volunteers were studied. Fifteen MRI scanners with field strength ranging from 0.08 T to 1.5 T were induced. Measurement accuracy was tested on the Eurospin relaxation time test object (TO5) and the obtained calibration curve was used for correction of the in vivo data. The results established that, by following a standardized procedure, comparable quantitative measurements can be obtained in vivo from a number of MR sites. The overall variation coefficient in vivo was in the same order of magnitude as ex vivo relaxometry. Thus, it is possible to carry out international multicenter studies on quantitative imaging, provided that quality control with respect to measurement accuracy and calibration of the MR equipments are performed.


Assuntos
Encéfalo/anatomia & histologia , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/normas , Músculos/anatomia & histologia , Adulto , Calibragem , União Europeia , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Modelos Estruturais , Projetos Piloto , Controle de Qualidade , Reprodutibilidade dos Testes
6.
Magn Reson Imaging ; 11(6): 851-6, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8371640

RESUMO

T1 and T2 relaxation times are fundamental parameters for signal contrast behaviour in MRI. A number of ex vivo relaxometry studies have dealt with the magnetic field dispersion of T1. By means of multicenter study within the frame of the COMAC BME Concerted Action on Tissue Characterization by MRI and MRS, the in vivo field dispersion of T1 and T2 has been measured in order to evaluate whether ex vivo data are representative for the in vivo situation. Brain, skeletal muscle, and liver of healthy human volunteers were studied. Fifteen MR units with a field strength ranging from 0.08 T to 1.5 T took part in the trial, which comprised 218 volunteers. All the MR systems were tested for measurement accuracy using the Eurospin TO5 test object. The measured relaxation data were subsequently corrected according to the obtained calibration curves. The results showed a clear field dispersion of T1, whereas no significant variations were seen for T2. Our in vivo data were generally in reasonable agreement with proposed models based on ex vivo measurements.


Assuntos
Encéfalo/anatomia & histologia , Fígado/anatomia & histologia , Imageamento por Ressonância Magnética/normas , Músculos/anatomia & histologia , Adulto , Calibragem , União Europeia , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Reprodutibilidade dos Testes
7.
Magn Reson Imaging ; 11(6): 857-64, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8371641

RESUMO

In an MR multicenter project, data exchange is a problem because most MR scanners do not use the same data format or have data export facilities. In the COMAC-BME Concerted Action on Tissue Characterization by MRS and MRI, a subgroup of seven MR centers had a need for data exchange in the form of digital MR images of the human brain. Because there was no common data format, software package was developed for data exchange. This article describes the basic features of the developed software. The software package was written in the language of C and was successfully tested on an IBM-6150 UNIX workstation. The software is currently being tested on the following series of UNIX workstations: SUN SPARC, IBM RS6000, and HP 9000/700.


Assuntos
Encéfalo/anatomia & histologia , Redes de Comunicação de Computadores , Imageamento por Ressonância Magnética , Software , Animais , União Europeia , Humanos , Processamento de Imagem Assistida por Computador , Design de Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA