Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 146(1): 85-9, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22818126

RESUMO

OBJECTIVE: The Heart Rhythm Society, European Heart Rhythm Association, and European Cardiac Arrhythmia Society jointly recommend indefinite warfarin anticoagulation in patients with CHADS2 (congestive heart failure, hypertension, age, diabetes, and stroke) score of at least 2 who have undergone ablation for atrial fibrillation. This study determined the impact of CHADS2 score on risk of late stroke or transient ischemic attack after the performance of a surgical Cox maze procedure. METHODS: A retrospective review of 433 patients who underwent a Cox maze procedure at our institution was conducted. Three months after surgery, warfarin was discontinued regardless of CHADS2 score if the patient showed no evidence of atrial fibrillation, was off antiarrhythmic medications, and had no other indication for anticoagulation. A follow-up questionnaire was used to determine whether any neurologic event had occurred since surgery. RESULTS: Follow-up was obtained for 90% of the study group (389/433) at a mean of 6.6 ± 5.0 years. Among these patients, 32% (125/389) had a CHADS2 score of at least 2, of whom only 40% (51/125) remained on long-term warfarin after surgery. Six patients had late neurologic events (annualized risk of 0.2%). Neither CHADS2 score nor warfarin anticoagulation was significantly associated with the occurrence of late neurologic events. Among the individual CHADS2 criteria, both diabetes mellitus and previous stroke or transient ischemic attack were predictive of late neurologic events. CONCLUSIONS: The risk of stroke or transient ischemic attack in patients after a surgical Cox maze procedure was low and not associated with CHADS2 score or warfarin use. Given the known risks of warfarin, we recommend discontinuation of anticoagulation 3 months after the procedure if the patient has no evidence of atrial fibrillation, has discontinued antiarrhythmic medications, and is without any other indication for systemic anticoagulation.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Complicações do Diabetes/complicações , Insuficiência Cardíaca/complicações , Hipertensão/complicações , Ataque Isquêmico Transitório/etiologia , Complicações Pós-Operatórias/etiologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/etiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Varfarina/uso terapêutico , Fatores Etários , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Gravidade do Paciente , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
2.
BMC Bioinformatics ; 7: 346, 2006 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-16842622

RESUMO

BACKGROUND: A structure alignment method based on a local geometric property is presented and its performance is tested in pairwise and multiple structure alignments. In this approach, the writhing number, a quantity originating from integral formulas of Vassiliev knot invariants, is used as a local geometric measure. This measure is used in a sliding window to calculate the local writhe down the length of the protein chain. By encoding the distribution of writhing numbers across all the structures in the protein databank (PDB), protein geometries are represented in a 20-letter alphabet. This encoding transforms the structure alignment problem into a sequence alignment problem and allows the well-established algorithms of sequence alignment to be employed. Such geometric alignments offer distinct advantages over structural alignments in Cartesian coordinates as it better handles structural subtleties associated with slight twists and bends that distort one structure relative to another. RESULTS: The performance of programs for pairwise local alignment (TLOCAL) and multiple alignment (TCLUSTALW) are readily adapted from existing code for Smith-Waterman pairwise alignment and for multiple sequence alignment using CLUSTALW. The alignment algorithms employed a blocked scoring matrix (TBLOSUM) generated using the frequency of changes in the geometric alphabet of a block of protein structures. TLOCAL was tested on a set of 10 difficult proteins and found to give high quality alignments that compare favorably to those generated by existing pairwise alignment programs. A set of protein comparison involving hinged structures was also analyzed and TLOCAL was seen to compare favorably to other alignment methods. TCLUSTALW was tested on a family of protein kinases and reveal conserved regions similar to those previously identified by a hand alignment. CONCLUSION: These results show that the encoding of the writhing number as a geometric measure allow high quality structure alignments to be generated using standard algorithms of sequence alignment. This approach provides computationally efficient algorithms that allow fast database searching and multiple structure alignment. Because the geometric measure can employ different window sizes, the method allows the exploration of alignments on different, well-defined length scales.


Assuntos
Alinhamento de Sequência/métodos , Software , Homologia Estrutural de Proteína , Algoritmos , Biologia Computacional/métodos , Bases de Dados de Proteínas , Modelos Estatísticos , Análise de Sequência de Proteína/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...