Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Obstet Gynecol Reprod Biol ; 84(1): 23-5, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10413222

RESUMO

OBJECTIVE: To determine the predictive factors for genital prolapse. STUDY DESIGN: We studied 85 young (< or = 45 year old) women who had been operated on for genital prolapse. The control group consisted of women of the same age operated on for benign ovarian tumor. RESULTS: In the study group the number of deliveries was higher and the babies were heavier than in the control group. However, the study group had not had more instrumental deliveries. In addition, the women with prolapses more often had operations of abdominal hernias and also had more chronic pulmonary disease, e.g. asthma. The incidence of preterm delivery was the same in the women with genital prolapse as in the controls. Familial incidence of genital prolapse was about 30%. CONCLUSION: Our study confirms that there are both acquired and congenital factors that predispose women to genital prolapse.


Assuntos
Prolapso Uterino/etiologia , Adulto , Fatores Etários , Animais , Peso ao Nascer , Índice de Massa Corporal , Peso Corporal , Estudos de Casos e Controles , Parto Obstétrico , Feminino , Humanos , Obesidade , Neoplasias Ovarianas/cirurgia , Paridade , Inquéritos e Questionários , Prolapso Uterino/cirurgia , Útero/cirurgia
2.
Prenat Diagn ; 19(4): 340-50, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10327140

RESUMO

Variable results have been reported using urine beta-core fragment as a marker for fetal Down syndrome. Initial studies by Cuckle et al. (1994) and Canick et al. (1995) indicated that beta-core fragment was an outstanding marker, detecting >80 per cent of Down syndrome cases. Since these reports, widely varying results have been published, indicating between 20 per cent and 66 per cent detection of cases at 5 per cent false-positive rate. The wide variation in the reported data has led to a loss of enthusiasm for this marker as a useful test for Down syndrome screening. Here we report the results of a three-year prospective study in which urine samples were collected daily from women undergoing fetal karyotype analysis for advanced maternal age. Samples were tested within one week of collection and then frozen. We also investigated the likely causes of the variability observed in beta-core fragment data. We collected 1157 urine samples over 955 days. Beta-core fragment levels were measured. A regression line was calculated for the weekly medians of the 1134 control samples and multiples of the control median (MoM) were determined. The median MoM for the controls was 1.0 and the logarithmic standard deviation (log SD) was 0.41. The median MoM for the 23 Down syndrome cases was 5.44 and the log SD was 0.45. Over the study period, 65 per cent of Down syndrome cases exceeded the 95th centile of the control group. The median MoM of control samples and the proportion of Down syndrome cases detected by the test was relatively constant during the study period. The unaffected cases were divided into three equal divisions, corresponding to approximately the first, second and third year of sample collection. No trend was found in the median control MoM values in three sample collection periods (r2=0.04). A similar number of cases exceeded the 95th centile of control samples in the three sample collection periods, 63 per cent, 66 per cent and 66 per cent. Consistent results were indicated during the three years of sample testing. Levels of total oestriol were determined in urine samples and MoM statistics derived. The median oestriol level in Down syndrome cases was 0.59 MoM. Only 12 per cent of cases had MoM levels below the fifth centile. Gaussian models were prepared combining biochemical data and maternal age distribution. While beta-core fragment by itself detected 65 per cent of Down syndrome cases, beta-core fragment modelled with maternal age detected 66 per cent, and modelled with age and total oestriol levels detected 82 per cent of cases at 5 per cent false-positive rate. At the completion of the study, we thawed and reassayed 20 random urine samples (10 control and 10 Down syndrome) collected at different times during the study period. While the control samples (74-1700 ng/ml) had slightly increased values when reassayed (mean value 137 per cent of original prospective value), the Down syndrome samples (360-20,500 ng/ml) all had decreased values when reassayed (mean=53 per cent, t-test, controls versus cases, p = 0.0003). The Down syndrome samples were decreased to between 93 per cent and 12 per cent of the original value. A relationship was identified between the magnitude of the original beta-core fragment value and the change in immunoreactivity when reassayed (r2=0.998). The higher the initial beta-core fragment value the greater the loss of immunoreactivity. We considered the possibility that the beta-core fragment molecules aggregate upon storage in the freezer. We repeated the assay of the 20 samples after treatment with a high salt buffer. Down syndrome samples recovered half of the lost beta-core fragment immunoreactivity (mean increase in beta-core fragment levels 56 per cent, t-test, controls versus cases, p=0.004). We infer that aggregation of beta-core fragment upon storage interferes with beta-core fragment measurements. This may be the cause of the poor beta-core fragment screening performance reported using sto


Assuntos
Biomarcadores/urina , Gonadotropina Coriônica Humana Subunidade beta/urina , Síndrome de Down/urina , Diagnóstico Pré-Natal/métodos , Creatinina/urina , Estabilidade de Medicamentos , Estriol/urina , Feminino , Doenças Fetais/urina , Idade Gestacional , Humanos , Cariotipagem , Idade Materna , Gravidez , Gravidez de Alto Risco , Estudos Prospectivos , Sensibilidade e Especificidade
3.
Prenat Diagn ; 19(4): 351-9, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10327141

RESUMO

Hyperglycosylated hCG is a form of hCG with more complex oligosaccharide side chains. A specific immunoassay was developed to measure hyperglycosylated hCG. Levels were measured in urine samples from 1157 women between 11 to 22 weeks of gestation, undergoing genetic analysis because of advanced maternal age. Values were normalized to urine creatinine concentration and plotted against gestational age, median values were determined and multiples of the control median (MoM) calculated. The median MoM and log standard deviation (log SD) of the 1134 control samples was 1.0 and 0.47, and of the 23 Down syndrome cases was 7.8 and 0.48, respectively. This indicated a 7.8-fold increase in hyperglycosylated hCG levels in Down syndrome cases. In the accompanying article, a stability problem was found with beta-core fragment measurements in frozen urine samples. In anticipation of similar problems, nine urine samples were tested for hyperglycosylated hCG fresh and after storage in the freezer. No clear difference was found in hyperglycosylated hCG values. In addition, no trend was found in hyperglycosylated hCG MoM values or in Down syndrome detection rates in urine samples stored for one, two or three years in the freezer. Samples were split into five equal groups according to creatinine concentration. A trend was observed, hyperglycosylated hCG MoM values decreasing with advancing creatinine concentration (1.77, 1.08, 1.01, 0.73 and 0.60 at 0.25, 0.50, 0.79, 1.11 and 1.73 mg/ml, respectively). An error was noted. This was corrected with a regression equation. After correction, the median MoM and log SD of the control samples was 1.0 and 0.44, and of Down syndrome samples was 7.3 and 0.42, respectively. Correction of this error, while reducing the elevation of Down syndrome cases, tightened the spread of samples. Samples were ranked and centiles determined. 18 of 23 Down syndrome cases (78 per cent) exceeded the 95th centile of the control population. ROC analysis indicated 79 per cent detection at 5 per cent false-positive rate. Urine samples were collected during two periods of gestation, an early period (11th to 14th completed week) and the period when chemical screening is normally performed (15th to 21st week). ROC analysis indicated 80 per cent and 78 per cent detection rates, respectively, at 5 per cent false-positive rate, in the two gestational periods. Hyperglycosylated hCG values were modelled with beta-core fragment values, total oestriol values and maternal age. ROC analysis indicated 97 per cent detection rate at 5 per cent false-positive rate. This detection rate and this level of Down syndrome and control patient discrimination surpasses that of any other serum, urine or ultrasound screening protocol. Hyperglycosylated hCG should be considered as a new screening test for aneuploid pregnancies, with the potential of detecting almost all cases of Down syndrome. Evaluation is needed by other centres in order to bring hyperglycosylated hCG into clinical practice.


Assuntos
Gonadotropina Coriônica/urina , Síndrome de Down/urina , Diagnóstico Pré-Natal/métodos , Creatinina/urina , Estabilidade de Medicamentos , Reações Falso-Positivas , Feminino , Doenças Fetais/urina , Congelamento , Idade Gestacional , Humanos , Gravidez , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...