Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Traumatol Surg Res ; 103(6): 959-963, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28645703

RESUMO

BACKGROUND: Although standard instrumentation is the procedure most frequently used to implant a Total Knee Arthroplasty (TKA), high rates of malalignment of tibial component are reported using this technique. Anatomical landmarks for sagittal alignment have been little investigated and the best reference axis, which parallels the mechanical axis, is yet to be established. HYPOTHESIS: Mapping the Anterior Tibial Profile (ATP) may allow the identification of segmental zones of the ATP parallel to the mechanical axis which can be used to align the extramedullary rod. METHODS: An intramedullary rod was positioned in line with the mechanical axis in 47 dried cadaveric tibiae. The rod was connected to a cutting jig and to an extramedullary rod. Digitalized images of lateral view radiographs were taken and the distance between the ATP and the extramedullary rod was measured at 10-mm intervals and at interpolated distances corresponding to every 2% of the tibial length. RESULTS: Segmental portions of the ATP exhibit an alignment parallel to the mechanical axis between points located at 58% and 90% and at 62% and 88% of the tibial length. Points placed at 50% of tibial length and 5mm proximal to the ankle joint generate the longer axis parallel to the mechanical axis. CONCLUSION: The orientation of sagittal tibial cut may be improved by aligning the extramedullary rod parallel to the ATP at definite points. Points placed at 50% of the tibial length and 5mm proximal to the ankle joint may be preferred since they generate the longer axis parallel to the mechanical axis and are more easily identified at surgery.


Assuntos
Artroplastia do Joelho/métodos , Mau Alinhamento Ósseo/prevenção & controle , Tíbia/diagnóstico por imagem , Cadáver , Feminino , Humanos , Masculino , Tíbia/cirurgia
2.
Knee Surg Sports Traumatol Arthrosc ; 25(8): 2594-2601, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26537596

RESUMO

PURPOSE: Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. METHODS: MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. RESULTS: The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. CONCLUSION: In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho/métodos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Adolescente , Adulto , Idoso , Artroplastia do Joelho/efeitos adversos , Cadáver , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/anatomia & histologia , Ligamento Cruzado Posterior/cirurgia , Adulto Jovem
3.
Knee Surg Sports Traumatol Arthrosc ; 23(12): 3563-70, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25218573

RESUMO

PURPOSE: Tibia torsion may influence the accuracy of extramedullary instrumentations in total knee arthroplasty (TKA). This study assessed whether the effect of tibial torsion may be overcome using a surgical technique in which the extramedullary rod is aligned to reference points at the proximal tibia only. METHODS: A consecutive series of 94 knees that underwent TKA were analyzed. In the first 47 knees (group 1), a standard procedure for tibial component alignment was performed while in the second group of 47 knees, a modified surgical technique was used including the alignment of the extramedullary rod to the reference points at the proximal tibia only (group 2). Lower limb, femoral, and tibial component alignment were measured on postoperative long-leg radiographs. RESULTS: Femorotibial mechanical axes angles were similar in the two groups. Femoral component alignment also did not differ between the groups. A neutral alignment of the tibial component was achieved in 17 and 34 % of the knees in group 1 and group 2, respectively (p = 0.04). A malalignment of the tibial component >3° was found in 34 % of knees in group 1 compared with 4 % of those in group 2 (p = 0.0001). CONCLUSIONS: Coronal alignment of the tibial component may improve by setting the extramedullary rod in line with anatomical references in the proximal tibia only. This technique appears to bypass the influence of tibial torsion on the alignment of the extramedullary guide at the distal tibia. The clinical relevance of the study is that using this technique, the rate of malalignment of the tibial component may be reduced compared to a standard technique in which a fixed reference is used at the ankle joint.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Idoso , Idoso de 80 Anos ou mais , Mau Alinhamento Ósseo/prevenção & controle , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Tomografia Computadorizada por Raios X , Torção Mecânica
4.
Orthop Traumatol Surg Res ; 99(1): 30-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23260613

RESUMO

BACKGROUND: Short femoral stems designed to spare bone stock and improve load transfer at the proximal femur level have been introduced in recent years. However, little is known on the long-term outcomes of these stems. HYPOTHESIS: Short cementless stems have low rate of thigh pain and subsidence as well as few revision needs at mid-term follow-up. MATERIALS AND METHODS: We prospectively followed 64 patients (72 hips) undergoing total hip arthroplasty with a femoral stem designed to achieve a pure metaphyseal fixation. Patients with hip fracture, femoral neck deformity and osteoporotic bone were excluded. Clinical evaluations were performed annually until the last follow-up, a minimum of 9 years after surgery. At each follow-up, implant positioning was assessed on conventional plain films with a computer assisted radiographic evaluation. RESULTS: The Harris hip score improved from 43 points (range 19-50) before surgery to 88 points (range 73-100) at the final follow-up (P=0.001), and the Womac score averaged 47 points (range 35-56 points) preoperatively and 76 points (range 63-84) at the last follow-up (P=0.001). Thigh pain was reported by five patients (8%) at the 2-year follow-up, but only in two (3%) was still present, and related to the prosthesis, at last follow-up. Computer assisted radiographic analysis showed a neutral alignment of the stem in 56% of cases, a varus-valgus alignment less than 5° in 36% and equal to 5° in 8%. Stem subsidence was observed in 12 hips but was less than 4mm in all cases (range 0-3mm). Calcar height remained unchanged over time. Adaptive bone remodelling, including proximal bone resorption and distal cortical hypertrophy were not observed at follow-up. No patients had aseptic loosening of the stem nor were radiolucent lines detectable at the level of the porous coating. Survivorship analysis showed a 100% survival rate of the stem at nine years. DISCUSSION: This study showed that a femoral stem designed to achieve a pure metaphyseal fixation may obtain, in a selected group of patients with adequate bone quality, satisfactory clinical outcomes without compromising implant stability. The limited periprosthetic bone remodelling observed after a minimum of 9 years follow-up suggests that this type of implant may improve mechanical stresses on host bone compared with standard stems requiring diaphyseal fixation. LEVEL OF EVIDENCE: Level IV. Historical series.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Seguimentos , Humanos , Estudos Prospectivos , Desenho de Prótese , Coxa da Perna , Resultado do Tratamento
5.
J Anat ; 221(5): 452-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22946518

RESUMO

The aim of this study was to address, in normal knees, the variability of posterior offset of femoral condyles and tibial slope, and the presence of any correlation between the two that might be needed to achieve an adequate joint motion in flexion. Magnetic resonance images of normal knees of 80 subjects, 45 males and 35 females, with a mean age of 38.9 years, were analysed. Measurements were performed by two independent observers using an imaging visualization software. The tibial slope averaged 8 and 7.7 °, on the medial and lateral sides, respectively (P = 0.2); the mean posterior offset of femoral condyles was 27.4 and 25.2 mm on the two sides, respectively (P = 0.0001). The variation coefficient of the condylar offset and tibial slope was 11.5 and 38%, respectively. In the medial compartment, a significant correlation was found between the femoral condylar offset and the tibial slope, while the same was not observed in the lateral compartment of the knee. Magnetic resonance imaging allows the assessment of tibial slope and femoral condylar offset in the medial and lateral side separately, taking into account any difference between the two compartments. The sagittal tibial slope exhibits a greater variability compared with the posterior offset of femoral condyles. The correlation found, in the medial compartment, between the tibial slope and femoral condylar offset suggests that the reconstitution of the proper morphology of the posterior part of the knee joint may be necessary to obtain a full range of motion in flexion after total knee replacement.


Assuntos
Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Amplitude de Movimento Articular/fisiologia , Tíbia/anatomia & histologia , Adulto , Fenômenos Biomecânicos , Feminino , Fêmur/fisiologia , Humanos , Articulação do Joelho/fisiologia , Imageamento por Ressonância Magnética , Masculino , Tíbia/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...