Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 13(9): 4834-4850, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36187237

RESUMO

Ultrasound optical tomography (UOT) is a hybrid imaging modality based on interaction between ultrasound and light, with a potential to extend optical imaging capabilities in biological tissues to depths of several centimeters. Several methods have been developed to detect the UOT signal. To better understand their potential for deep tissue imaging, we present a theoretical contrast-to-noise comparison between the spectral hole burning, single-shot off-axis holography, speckle contrast, and photorefractive detection methods for UOT. Our results indicate that spectral hole burning filters have the potential to reach the largest imaging depths. We find that digital off-axis holography and photorefractive detection can have good contrast-to-noise ratio at significant depths. The speckle contrast method has a smaller penetration depth comparatively.

2.
Rev Sci Instrum ; 91(10): 105114, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33138548

RESUMO

We present a simple technique to experimentally determine the optical-path length change with temperature for optical single-mode fibers. Standard single-mode fibers act as natural low-finesse cavities, with the Fresnel reflection of the straight cleaved surfaces being ∼3%, for the laser light coupled to them. By measuring the intensity variations due to interference of light reflected from the fiber front and end surfaces, while ramping the ambient temperature, the thermal sensitivity of the optical-path length of the fiber can be derived. Light was generated by a narrow linewidth, low drift laser. With our fairly short test fibers, we found that it was possible to reach a relative precision of the temperature sensitivity, compared to a reference fiber, on the 0.4%-2% scale and an absolute precision of 2%-5%, with the potential to improve both by an order of magnitude. The results for single-acrylate, dual-acrylate, and copper- and aluminum-coated fibers are presented. Values are compared with analytic models and results from a finite element method simulation. With the aid of these measurements, a simple fiber-interferometer, which is insensitive to thermal drifts, could be constructed.

3.
Biomed Opt Express ; 10(11): 5565-5584, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31799031

RESUMO

Ultrasound optical tomography (UOT) is an imaging technique based on the acousto-optic effect that can perform optical imaging with ultrasound resolution inside turbid media, and is thus interesting for biomedical applications, e.g. for assessing tissue blood oxygenation. In this paper, we present near background free measurements of UOT signal strengths using slow light filter signal detection. We carefully analyze each part of our experimental setup and match measured signal strengths with calculations based on diffusion theory. This agreement between experiment and theory allows us to assert the deep tissue imaging potential of ∼ 5 cm for UOT of real human tissues predicted by previous theoretical studies [Biomed. Opt. Express8, 4523 (2017)] with greater confidence, and indicate that future theoretical analysis of optimized UOT systems can be expected to be reliable.

4.
Opt Express ; 27(6): 8267-8282, 2019 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-31052648

RESUMO

High-fidelity qubit initialization is of significance for efficient error correction in fault tolerant quantum algorithms. Combining two best worlds, speed and robustness, to achieve high-fidelity state preparation and manipulation is challenging in quantum systems, where qubits are closely spaced in frequency. Motivated by the concept of shortcut to adiabaticity, we theoretically propose the shortcut pulses via inverse engineering and further optimize the pulses with respect to systematic errors in frequency detuning and Rabi frequency. Such protocol, relevant to frequency selectivity, is applied to rare-earth ions qubit system, where the excitation of frequency-neighboring qubits should be prevented as well. Furthermore, comparison with adiabatic complex hyperbolic secant pulses shows that these dedicated initialization pulses can reduce the time that ions spend in the excited state by a factor of 6, which is important in coherence time limited systems to approach an error rate manageable by quantum error correction. The approach may also be applicable to superconducting qubits, and any other systems where qubits are addressed in frequency.

5.
J Biomed Opt ; 23(7): 1-8, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29701019

RESUMO

Biological tissue is a highly scattering medium that prevents deep imaging of light. For medical applications, optical imaging offers a molecular sensitivity that would be beneficial for diagnosing and monitoring of diseases. Acousto-optical tomography has the molecular sensitivity of optical imaging with the resolution of ultrasound and has the potential for deep tissue imaging. Here, we present a theoretical study of a system that combines acousto-optical tomography and slow light spectral filters created using spectral hole burning methods. Using Monte Carlo simulations, a model to obtain the contrast-to-noise ratio (CNR) deep in biological tissue was developed. The simulations show a CNR > 1 for imaging depths of ∼5 cm in a reflection mode setup, as well as, imaging through ∼12 cm in transmission mode setups. These results are promising and form the basis for future experimental studies.


Assuntos
Técnicas Fotoacústicas/métodos , Tomografia Óptica/métodos , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Modelos Biológicos , Método de Monte Carlo , Músculos/diagnóstico por imagem , Ultrassonografia
6.
Biomed Opt Express ; 8(10): 4523-4536, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29082082

RESUMO

Despite the important medical implications, it is currently an open task to find optical non-invasive techniques that can image deep organs in humans. Addressing this, photo-acoustic tomography (PAT) has received a great deal of attention in the past decade, owing to favorable properties like high contrast and high spatial resolution. However, even with optimal components PAT cannot penetrate beyond a few centimeters, which still presents an important limitation of the technique. Here, we calculate the absorption contrast levels for PAT and for ultrasound optical tomography (UOT) and compare them to their relevant noise sources as a function of imaging depth. The results indicate that a new development in optical filters, based on rare-earth-ion crystals, can push the UOT technique significantly ahead of PAT. Such filters allow the contrast-to-noise ratio for UOT to be up to three orders of magnitude better than for PAT at depths of a few cm into the tissue. It also translates into a significant increase of the image depth of UOT compared to PAT, enabling deep organs to be imaged in humans in real time. Furthermore, such spectral holeburning filters are not sensitive to speckle decorrelation from the tissue and can operate at nearly any angle of incident light, allowing good light collection. We theoretically demonstrate the improved performance in the medically important case of non-invasive optical imaging of the oxygenation level of the frontal part of the human myocardial tissue. Our results indicate that further studies on UOT are of interest and that the technique may have large impact on future directions of biomedical optics.

7.
Rev Sci Instrum ; 87(3): 033701, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27036778

RESUMO

A compact sample-scanning confocal optical microscope for detection of single impurities below the surface of a bulk crystal at cryogenic temperatures is described. The sample, lens, and scanners are mounted inside a helium bath cryostat and have a footprint of only 19 × 19 mm. Wide field imaging and confocal imaging using a Blu-ray lens immersed in liquid helium are demonstrated with excitation at 370 nm. A spatial resolution of 300 nm and a detection efficiency of 1.6% were achieved.

8.
Appl Opt ; 55(36): 10442-10448, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-28059275

RESUMO

The present work addresses critical issues in constructing high suppression, narrowband spectral filters in rare-earth-ion-doped crystals, mainly targeting the application of ultrasound optical tomography but is also applicable for areas such as quantum memories, self-filtering of laser frequencies, and other applications relying on high absorption in rare-earth-ion-doped crystals. The polarization of light transmitted through a highly absorbing crystal is experimentally analyzed. Additionally, an existing wave propagation method is used to simulate beam propagation through a spectral hole to study the high étendue requirements of ultrasound optical tomography.

9.
Phys Rev Lett ; 111(18): 183602, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24237519

RESUMO

More than 4 orders of magnitude of cavity-linewidth narrowing in a rare-earth-ion-doped crystal cavity, emanating from strong intracavity dispersion caused by off-resonant interaction with dopant ions, is demonstrated. The dispersion profiles are engineered using optical pumping techniques creating significant semipermanent but reprogrammable changes of the rare-earth absorption profiles. Several cavity modes are shown within the spectral transmission window. Several possible applications of this phenomenon are discussed.

10.
Phys Rev Lett ; 110(13): 133604, 2013 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-23581321

RESUMO

A light-storage experiment with a total (storage and retrieval) efficiency η=56% is carried out by enclosing a sample, with a single-pass absorption of 10%, in an impedance-matched cavity. The experiment is carried out using the atomic frequency comb (AFC) technique in a praseodymium-doped crystal (0.05%Pr(3+):Y2SiO5) and the cavity is created by depositing reflection coatings directly onto the crystal surfaces. The AFC technique has previously by far demonstrated the highest multimode capacity of all quantum memory concepts tested experimentally. We claim that the present work shows that it is realistic to create efficient, on-demand, long storage time AFC memories.

11.
Appl Phys Lett ; 100(13): 131102-1311025, 2012 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-22509069

RESUMO

Slow light has been extensively studied for applications ranging from optical delay lines to single photon quantum storage. Here, we show that the time delay of slow-light significantly improves the performance of the narrowband spectral filters needed to optically detect ultrasound from deep inside highly scattering tissue. We demonstrate this capability with a 9 cm thick tissue phantom, having 10 cm(-1) reduced scattering coefficient, and achieve an unprecedented background-free signal. Based on the data, we project real time imaging at video rates in even thicker phantoms and possibly deep enough into real tissue for clinical applications like early cancer detection.

12.
Opt Express ; 18(26): 27670-81, 2010 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-21197041

RESUMO

A difference-frequency generation based spectrometer system for simultaneous ultra-sensitive measurements of formaldehyde (CH2O) and Methane (CH4) is presented. A new multiplexing approach using collinear quasi-phase-matching in a single grating period of periodically poled lithium niobate (PPLN) is discussed and demonstrated for two pairs of pump and signal lasers to generate mid-infrared frequencies at 2831.64 cm(-1) and 2916.32 cm(-1), respectively. The corresponding absorption signals are discriminated by modulating the DFB diode lasers at modulation frequencies of 40 kHz and 50 kHz, respectively, and using a computer based modulation and de-modulation scheme. In addition, simultaneous measurements of CH2O, CH4 and H2O are demonstrated utilizing both collinear and non-collinear quasi-phase-matching.


Assuntos
Misturas Complexas/análise , Formaldeído/análise , Lasers , Metano/análise , Análise Espectral/instrumentação , Análise Espectral/métodos , Desenho de Equipamento , Análise de Falha de Equipamento
13.
Opt Lett ; 33(1): 80-2, 2008 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-18157265

RESUMO

We present minimalistic and cost-efficient instrumentation employing tunable diode laser gas spectroscopy for the characterization of porous and highly scattering solids. The sensitivity reaches 3 x 10(-6) (absorption fraction), and the improvement with respect to previous work in this field is a factor of 10. We also provide the first characterization of the interference phenomenon encountered in high-resolution spectroscopy of turbid samples. Revealing that severe optical interference originates from the samples, we discuss important implications for system design. In addition, we introduce tracking coils and sample rotation as new and efficient tools for interference suppression. The great value of the approach is illustrated in an application addressing structural properties of pharmaceutical materials.


Assuntos
Gases/análise , Gases/química , Iluminação/instrumentação , Nefelometria e Turbidimetria/instrumentação , Análise Espectral/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Luz , Porosidade , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...