Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Innovations (Phila) ; 16(1): 43-51, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33269957

RESUMO

OBJECTIVE: Risk-scoring systems for surgical aortic valve replacement (AVR) were largely derived from sternotomy cases. We evaluated the accuracy of current risk scores in predicting outcomes after minimally invasive AVR (mini-AVR). Because transcatheter AVR (TAVR) is being considered for use in low-risk patients with aortic stenosis, accurate mini-AVR risk assessment is necessary. METHODS: We reviewed 1,018 consecutive isolated mini-AVR cases (2009 to 2015). After excluding patients with Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores ≥4, we calculated each patient's European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, TAVR Risk Score (TAVR-RS), and age, creatinine, and ejection fraction score (ACEF). We compared all 4 scores' accuracy in predicting mini-AVR 30-day mortality by computing each score's observed-to-expected mortality ratio (O:E). Area under the receiver operating characteristic (ROC) curves tested discrimination, and the Hosmer-Lemeshow goodness-of-fit tested calibration. RESULTS: Among 941 patients (mean age, 72 ± 12 years), 6 deaths occurred within 30 days (actual mortality rate, 0.6%). All 4 scoring systems overpredicted expected mortality after mini-AVR: ACEF (1.4%), EuroSCORE II (1.9%), STS-PROM (2.0%), and TAVR-RS (2.1%). STS-PROM best estimated risk for patients with STS-PROM scores 0 to <1 (0.6 O:E), ACEF for patients with STS-PROM scores 2 to <3 (0.6 O:E), and TAVR-RS for patients with STS-PROM scores 3 to <4 (0.7 O:E). ROC curves showed only fair discrimination and calibration across all risk scores. CONCLUSIONS: In low-risk patients who underwent mini-AVR, current surgical scoring systems overpredicted mortality 2-to-3-fold. Alternative dedicated scoring systems for mini-AVR are needed for more accurate outcomes assessment.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...