Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 12(4): 401-9, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16084428

RESUMO

BACKGROUND: Subdiaphragmatic activity and diaphragmatic motion both contribute to inferior wall artifacts in technetium 99m myocardial perfusion single photon emission computed tomography (SPECT). METHODS AND RESULTS: We used an anthropomorphic phantom with ventricular wall activity, liver/spleen inserts containing variable Tc-99m activity, and variable vertical (diaphragmatic) motion amplitude. SPECT and transmission scans were obtained on a GE Optima NX camera. Data were processed by use of filtered backprojection or attenuation correction (AC). Resulting myocardial activity maps were analyzed with standardized inferior-anterior and anterior-lateral wall ratios. At a subdiaphragmatic-myocardial activity ratio of 0.5:1, inferior wall attenuation predominates, producing a cold artifact. AC corrects inferior wall activity to the level of the anterior wall irrespective of diaphragmatic motion. At a subdiaphragmatic-myocardial activity ratio of 1:1, inferior wall counts vary widely depending on the proximity of subdiaphragmatic activity to the ventricle. With increasing diaphragmatic amplitude, the overlap of subdiaphragmatic activity and inferior wall worsens, leading to a complex mixture of cold and hot artifacts, not corrected by AC. CONCLUSIONS: Concentration and proximity of subdiaphragmatic Tc-99m activity relative to myocardium comprise a major factor in the nature and severity of inferior wall artifacts. If the subdiaphragmatic Tc-99m concentration is equivalent to that in the myocardium, complex, potentially uninterpretable hot and cold inferior wall artifacts are produced.


Assuntos
Artefatos , Diafragma/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Coração/diagnóstico por imagem , Compostos de Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Aumento da Imagem/métodos , Movimento , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
2.
J Nucl Med ; 43(9): 1259-67, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12215568

RESUMO

UNLABELLED: The goal of this study was to assess the effect of diaphragmatic respiratory motion on inferior wall cold artifact in myocardial SPECT and to assess the ability of attenuation correction (AC) to correct for this artifact in the presence of diaphragmatic motion. METHODS: We used an anthropomorphic phantom with ventricular wall activity, variable ventricular caudal tilt, attenuating liver and spleen cold inserts, and variable vertical (diaphragmatic) motion amplitude and pattern. Cardiac SPECT images were acquired on a gamma camera with dual scanning transmission line sources and commercially available AC software (with scatter correction and iterative reconstruction). The acquired data were processed either using filtered backprojection or with the AC software. The resulting myocardial activity maps were processed with polar plots and with standardized inferior-to-anterior and anterior-to-lateral wall ratios. RESULTS: Subdiaphragmatic attenuation reduces inferior wall counts and this component of inferior wall artifact is fully corrected by AC relative to anterior wall counts both with and without diaphragmatic respiratory motion. In the phantom, diaphragmatic motion artifact manifests as reduction in relative count density in both the anterior wall and the inferior wall relative to the lateral wall, which is not corrected by AC. This artifact becomes more marked with increasing respiratory amplitude and its symmetry depends on the pattern of diaphragmatic motion. CONCLUSION: Images with AC acquired at small respiratory amplitudes (approximately 2 cm) in the phantom resemble images with AC found in published normal patient databases. These results support a clinical need for respiratory gating of myocardial SPECT images.


Assuntos
Diafragma/fisiologia , Coração/diagnóstico por imagem , Mecânica Respiratória , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Artefatos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA