Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38793876

RESUMO

This study examined the efficacy of an optimized DeepLabCut (DLC) model in motion capture, with a particular focus on the sit-to-stand (STS) movement, which is crucial for assessing the functional capacity in elderly and postoperative patients. This research uniquely compared the performance of this optimized DLC model, which was trained using 'filtered' estimates from the widely used OpenPose (OP) model, thereby emphasizing computational effectiveness, motion-tracking precision, and enhanced stability in data capture. Utilizing a combination of smartphone-captured videos and specifically curated datasets, our methodological approach included data preparation, keypoint annotation, and extensive model training, with an emphasis on the flow of the optimized model. The findings demonstrate the superiority of the optimized DLC model in various aspects. It exhibited not only higher computational efficiency, with reduced processing times, but also greater precision and consistency in motion tracking thanks to the stability brought about by the meticulous selection of the OP data. This precision is vital for developing accurate biomechanical models for clinical interventions. Moreover, this study revealed that the optimized DLC maintained higher average confidence levels across datasets, indicating more reliable and accurate detection capabilities compared with standalone OP. The clinical relevance of these findings is profound. The optimized DLC model's efficiency and enhanced point estimation stability make it an invaluable tool in rehabilitation monitoring and patient assessments, potentially streamlining clinical workflows. This study suggests future research directions, including integrating the optimized DLC model with virtual reality environments for enhanced patient engagement and leveraging its improved data quality for predictive analytics in healthcare. Overall, the optimized DLC model emerged as a transformative tool for biomechanical analysis and physical rehabilitation, promising to enhance the quality of patient care and healthcare delivery efficiency.


Assuntos
Movimento , Redes Neurais de Computação , Humanos , Movimento/fisiologia , Fenômenos Biomecânicos/fisiologia , Masculino , Feminino , Smartphone , Adulto , Postura Sentada , Posição Ortostática , Captura de Movimento
2.
Materials (Basel) ; 12(11)2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31151256

RESUMO

The field of dental implantology has made progress in recent years, allowing safer and predictable oral rehabilitations. Surely the rehabilitation times have also been reduced, thanks to the advent of the new implant surfaces, which favour the osseointegration phases and allow the clinician to rehabilitate their patients earlier. To carry out this study, a search was conducted in the Pubmed, Embase and Elsevier databases; the articles initially obtained according to the keywords used numbered 283, and then subsequently reduced to 10 once the inclusion and exclusion criteria were applied. The review that has been carried out on this type of surface allows us to fully understand the features and above all to evaluate all the advantages or not related. The study materials also are supported by a manufacturing company, which provided all the indications regarding surface treatment and confocal microscopy scans. In conclusion, we can say that, thanks to these new surfaces, it has been possible to shorten the time necessary to obtain osseointegration and, therefore, secondary stability on the part of implants. The surfaces, therefore, guarantee an improved cellular adhesion and thanks to the excellent wettability all the biological processes that derive from it, such as increases in the exposed implant surface, resulting in an increase in bone-implant contact (BIC).

3.
Materials (Basel) ; 12(4)2019 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-30781478

RESUMO

The objective of this investigation was to analyze the mechanical features of two different prosthetic retention devices. By applying engineering tools like the finite element method (FEM) and Von Mises analyses, we investigated how dental implant devices hold out against masticatory strength during chewing cycles. Two common dental implant overdenture retention systems were analyzed and then compared with a universal-common dental abutment. The Equator® attachment system and the Locator® arrangement were processed using the FEM Ansys® Workbench. The elastic features of the materials used in the study were taken from recent literature. Results revealed different responses for both the devices, and both systems guaranteed a perfect fit over the axial load. However, the different design and shape involves the customized use of each device for a typical clinical condition of applying overdenture systems over dental implants. The data from this virtual model showed different features and mechanical behaviors of the overdenture prosthodontics attachments. A three-dimensional system involved the fixture, abutment, and passant screws of three different dental implants that were created and analyzed. Clinicians should find the best prosthetic balance to better distribute the stress over the component, and to guarantee the patients clinical long-term results.

4.
Materials (Basel) ; 11(9)2018 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-30142897

RESUMO

The objective of the present investigation was to evaluate how dental implant positioning can influence the masticatory stress distribution over screwed mandibular prosthodontics restoration and over the surrounding bone tissue. Moreover, the dental implant components and overdenture bar strengths under masticatory cycles have been investigated in order to evaluate possible screw and prosthesis breakage. A "virtual jaw" model and 3D dental implant were reproduced to realise finite element analysis in order to underline the parameters and the mechanical characteristics of the bone and of the dental implants connected to the overdenture bar. The distribution of a nonspecific chewing phase, analysing the overall load on the fixtures of the lower jaw, was performed. The study investigating frontal and horizontal planes and vertical directions of occlusal forces showed how position and perspective of fixtures strongly influenced the stress distribution and the consequent jawbone tissue remodelling. Prostheses elements such as cantilever, passing screws, and dental implants are strictly related to the correct selection of dental implant position. This study suggested a virtual method to guide the surgeon in the choice of implant number, position, diameter, and length, and cantilever length and shape, and to evaluate the prospective stress distribution of chewing strengths for a correct prosthesis rehabilitation.

5.
Int J Clin Exp Med ; 7(4): 817-25, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24955150

RESUMO

Prosthetic rehabilitation of partial or total edentulous patients is today a challenge for clinicians and dental practitioners. The application of dental implants in order to recover areas of missing teeth is going to be a predictable technique, however some important points about the implant angulation, the stress distribution over the bone tissue and prosthetic components should be well investigated for having final long term clinical results. Two different system of the prosthesis fixation are commonly used. The screw retained crown and the cemented retained one. All of the two restoration techniques give to the clinicians several advantages and some disadvantages. Aim of this work is to evaluate all the mechanical features of each system, through engineering systems of investigations like FEM and Von Mises analyses. The FEM is today a useful tool for the prediction of stress effect upon material and biomaterial under load or strengths. Specifically three different area has been evaluated through this study: the dental crown with the bone interface; the passant screw connection area; the occlusal surface of the two different type of crown. The elastic features of the materials used in the study have been taken from recent literature data. Results revealed an adequate response for both type of prostheses, although cemented retained one showed better results over the occlusal area.

6.
Parkinsons Dis ; 2012: 541908, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23320249

RESUMO

Parkinson's disease (PD) is a progressive neurodegenerative disorder related to the loss or absence of dopaminergic neurons in the brain. These deficits result in slowness of movement, tremor, rigidity, and dysfunction of behaviour. These symptoms negatively influence the patient's capability to carry out the daily oral hygiene manoeuvres. The aim of this work is to record the oral health condition of PD patients evaluated at the IRCSS Bonino-Puleio in Messina. The oral health of 45 consecutive PD patients (study group) with neurologic diagnosis based on United Kingdom Brain Bank Criteria has been compared with that of another 45 no PD patients of the same age (control group). The evaluation of the general oral condition was recorded underlining tooth loss, active periodontal disease, and presence of untreated caries. The frequency of untreated caries, periodontal diseases, and missing teeth of the study group was significantly higher than in control group. Based on the data results, clinicians should direct high attention to the oral hygiene of patients with PD, above all at the early stages of the caries or periodontal disease, in order to prevent serious evolution of those pathologic dental conditions that may finally result in the tooth extraction event.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...