Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Invest Radiol ; 27(5): 337-40, 1992 May.
Artigo em Inglês | MEDLINE | ID: mdl-1582814

RESUMO

RATIONALE AND OBJECTIVES: This study addresses the theoretical, experimental, and clinical application of using a central venous catheter system (CVS) for the rapid injection of contrast media during computed tomography (CT). METHODS: Application of Poiseuille's law and the Reynolds equation yielded theoretical data. In-line pressures were measured in experimental models and patients undergoing CT. Diatrizoate meglumine and iohexal contrast media were evaluated. RESULTS: The Reynolds number was consistent with laminar flow, allowing the application of Poiseuille's law. The calculated and experimental catheter tubing-chamber connection pressures were safe for both contrast media, at rates of 1 mL/second for long catheter tubing and 2 mL/second for short tubing. Thirteen patients had measured pressures within safety limits with no complications. CONCLUSIONS: This study establishes that power injection of contrast media via a CVS during CT is a safe procedure. Benefits include no need for peripheral intravenous catheter placement, decreased paramedical staff radiation exposure, and improved CT image quality.


Assuntos
Cateterismo Venoso Central/instrumentação , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X/instrumentação , Diatrizoato de Meglumina/administração & dosagem , Segurança de Equipamentos , Estudos de Avaliação como Assunto , Feminino , Humanos , Iohexol/administração & dosagem , Masculino , Pressão
3.
Health Phys ; 61(5): 601-8, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1752742

RESUMO

Broad beam geometry was used to measure the x-ray transmission properties of gypsum wallboard, steel, plate glass, and concrete for x-ray tube potentials of 50-125 kVp using an x-ray generator having a three-phase, twelve-pulse waveform and total initial beam filtration sufficient to provide half-value layers representative of those found in common practice and required by regulatory agencies. Measurement results are presented graphically and as numerical fits to a mathematical model of broad beam transmission to permit their use in the design of protective barriers for medical diagnostic x-ray facilities.


Assuntos
Proteção Radiológica , Serviço Hospitalar de Radiologia , Sulfato de Cálcio , Materiais de Construção , Vidro , Aço
7.
Proc Natl Acad Sci U S A ; 74(5): 1983-7, 1977 May.
Artigo em Inglês | MEDLINE | ID: mdl-194245

RESUMO

A therapeutic strategy for combined radiotherapy and chemotherapy of experimental solid tumors has been devised. More effective utilization of combined chemotherapy and radiotherapy may be realized clinically if comparable information is obtained in man. The overall treatment efficiency of successive courses of treatment has been determined by a method that defines tumor response quantitatively over an entire spectrum of tumor responses. The findings of this study have shown that an individual tumor that responds well to the first course of therapy will respond well to the second and third courses of combined modality therapy. Various solid tumors in different animal species have demonstrated variability of response to treatment, analogous to the many types of response found clinically.


Assuntos
Fluoruracila/uso terapêutico , Neoplasias Experimentais/tratamento farmacológico , Neoplasias Experimentais/radioterapia , Animais , Carcinoma Hepatocelular/terapia , Feminino , Neoplasias Hepáticas , Ratos , Ratos Endogâmicos ACI , Fatores de Tempo , Raios X
8.
Indiana Nurse ; 34(4): 19-22, 1970 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-4099921
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...