Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Small ; : e2307742, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326101

RESUMO

Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.

2.
Nat Commun ; 13(1): 2121, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35440595

RESUMO

Magnetic sensors are widely used in our daily life for assessing the position and orientation of objects. Recently, the magnetic sensing modality has been introduced to electronic skins (e-skins), enabling remote perception of moving objects. However, the integration density of magnetic sensors is limited and the vector properties of the magnetic field cannot be fully explored since the sensors can only perceive field components in one or two dimensions. Here, we report an approach to fabricate high-density integrated active matrix magnetic sensor with three-dimensional (3D) magnetic vector field sensing capability. The 3D magnetic sensor is composed of an array of self-assembled micro-origami cubic architectures with biased anisotropic magnetoresistance (AMR) sensors manufactured in a wafer-scale process. Integrating the 3D magnetic sensors into an e-skin with embedded magnetic hairs enables real-time multidirectional tactile perception. We demonstrate a versatile approach for the fabrication of active matrix integrated 3D sensor arrays using micro-origami and pave the way for new electronic devices relying on the autonomous rearrangement of functional elements in space.


Assuntos
Percepção do Tato , Dispositivos Eletrônicos Vestíveis , Magnetismo , Pele
3.
Sci Adv ; 7(51): eabl5408, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34919439

RESUMO

Existing electronically integrated catheters rely on the manual assembly of separate components to integrate sensing and actuation capabilities. This strongly impedes their miniaturization and further integration. Here, we report an electronically integrated self-assembled microcatheter. Electronic components for sensing and actuation are embedded into the catheter wall through the self-assembly of photolithographically processed polymer thin films. With a diameter of only about 0.1 mm, the catheter integrates actuated digits for manipulation and a magnetic sensor for navigation and is capable of targeted delivery of liquids. Fundamental functionalities are demonstrated and evaluated with artificial model environments and ex vivo tissue. Using the integrated magnetic sensor, we develop a strategy for the magnetic tracking of medical tools that facilitates basic navigation with a high resolution below 0.1 mm. These highly flexible and microsized integrated catheters might expand the boundary of minimally invasive surgery and lead to new biomedical applications.

4.
Sci Adv ; 7(44): eabj0767, 2021 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-34705511

RESUMO

Oscillations at several hertz are a key feature of dynamic behavior of various biological entities, such as the pulsating heart, firing neurons, or the sperm-beating flagellum. Inspired by nature's fundamental self-oscillations, we use electroactive polymer microactuators and three-dimensional microswitches to create a synthetic electromechanical parametric relaxation oscillator (EMPRO) that relies on the shape change of micropatterned polypyrrole and generates a rhythmic motion at biologically relevant stroke frequencies of up to ~95 Hz. We incorporate an Ag-Mg electrochemical battery into the EMPRO for autonomous operation in a nontoxic environment. Such a self-sufficient self-oscillating microsystem offers new opportunities for artificial life at low Reynolds numbers by, for instance, mimicking and replacing nature's propulsion and pumping units.

5.
Adv Mater ; 33(26): e2101272, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34028906

RESUMO

Many modern electronic applications rely on functional units arranged in an active-matrix integrated on a single chip. The active-matrix allows numerous identical device pixels to be addressed within a single system. However, next-generation electronics requires heterogeneous integration of dissimilar devices, where sensors, actuators, and display pixels sense and interact with the local environment. Heterogeneous material integration allows the reduction of size, increase of functionality, and enhancement of performance; however, it is challenging since front-end fabrication technologies in microelectronics put extremely high demands on materials, fabrication protocols, and processing environments. To overcome the obstacle in heterogeneous material integration, digital electrochemistry is explored here, which site-selectively carries out electrochemical processes to deposit and address electroactive materials within the pixel array. More specifically, an amorphous indium-gallium-zinc oxide (a-IGZO) thin-film-transistor (TFT) active-matrix is used to address pixels within the matrix and locally control electrochemical reactions for material growth and actuation. The digital electrochemistry procedure is studied in-depth by using polypyrrole (PPy) as a model material. Active-matrix-driven multicolored electrochromic patterns and actuator arrays are fabricated to demonstrate the capabilities of this approach for material integration. The approach can be extended to a broad range of materials and structures, opening up a new path for advanced heterogeneous microsystem integration.

6.
J Phys Condens Matter ; 31(12): 124001, 2019 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-30572317

RESUMO

In organic and hybrid photovoltaic devices, the asymmetry required for charge separation necessitates the use of a donor and an acceptor material, resulting in the formation of internal interfaces in the device active layer. While the core objective of these interfaces is to facilitate charge separation, bound states between electrons and holes may form across them, resulting in a loss mechanism that diminishes the performance of the solar cells. These interfacial transitions appear in organic systems as charge transfer (CT) states and as bound charge pairs (BCP) in hybrid systems. Despite being similar, the latter are far less investigated. Herein, we employ photothermal deflection spectroscopy and pump-push-probe experiments in order to determine the characteristics and dynamics of interfacial states in two model systems: an organic P3HT:PCBM and hybrid P3HT:ZnO photovoltaic layer. By controlling the area of the internal interface, we identify CT states between 1.4 eV and 1.8 eV in the organic bulk-heterojunction (BHJ) and BCP between 1.1 eV and 1.4 eV in the hybrid BHJ. The energetic distribution of these states suggests that they not only contribute to losses in photocurrent, but also significantly limit the possible maximum open circuit voltage obtainable from these devices.

7.
ACS Omega ; 3(8): 10042-10047, 2018 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-31459132

RESUMO

Perovskite-based solar cells are promising because of their rapidly improving efficiencies but suffer from instability issues. Recently, it has been claimed that one of the key contributors to the instability of perovskite solar cells is ion migration-induced electrode degradation, which can be avoided by incorporating inorganic hole-blocking layers (HBLs) in the device architecture. In this work, we investigate the operational environmental stability of methylammonium lead iodide perovskite solar cells that contain either an inorganic or organic HBL, with only the former effectively blocking ions from migrating to the metal electrode. This is confirmed by X-ray photoemission spectroscopy measured on the electrodes of degraded devices, where only electrodes of devices with an organic HBL show a significant iodine signal. Despite this, we show that when these devices are degraded under realistic operational conditions (i.e., constant illumination in a variety of atmospheric conditions), both types of devices exhibit nearly identical degradation behavior. These results demonstrate that contrary to prior suggestions, ion-induced electrode degradation is not the dominant factor in perovskite environmental instability under operational conditions.

8.
PLoS One ; 12(6): e0179276, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28628638

RESUMO

To use the "apparent diffusion coefficient" (Dapp) as a quantitative imaging parameter, well-suited test fluids are essential. In this study, the previously proposed aqueous solutions of polyvinylpyrrolidone (PVP) were examined and temperature calibrations were obtained. For example, at a temperature of 20°C, Dapp ranged from 1.594 (95% CI: 1.593, 1.595) µm2/ms to 0.3326 (95% CI: 0. 3304, 0.3348) µm2/ms for PVP-concentrations ranging from 10% (w/w) to 50% (w/w) using K30 polymer lengths. The temperature dependence of Dapp was found to be so strong that a negligence seems not advisable. The temperature dependence is descriptively modelled by an exponential function exp(c2 (T - 20°C)) and the determined c2 values are reported, which can be used for temperature calibration. For example, we find the value 0.02952 K-1 for 30% (w/w) PVP-concentration and K30 polymer length. In general, aqueous PVP solutions were found to be suitable to produce easily applicable and reliable Dapp-phantoms.


Assuntos
Imagem de Difusão por Ressonância Magnética , Povidona/química , Calibragem , Imagens de Fantasmas , Polímeros/química , Soluções/química , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...