Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Odontology ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136844

RESUMO

This research analyzed the effect of the manufacturing method on the flexural strength and color stability of 3D-printed resins used for producing indirect restorations. For this, two dental restorative biocompatible resin materials, OnX (OnX, SprintRay) and CB (Crown and Bridge, Dentca), were divided into 2 groups according with manufacturing method (printed with a Pro95 3D printer - SprintRay; and not printed, with samples obtained with the fluid resin being poured on PVS molds for further light activation in the post-curing process), and subdivided into 2 groups according to the post-curing method: VG (Valo Grand, Ultradent Products) for 120 s and PC (Procure 2, SprintRay). Bar-shaped samples were used to evaluate the flexural strength 24 h after storage in distilled water at 37 °C using a universal testing machine. Disk-shaped samples were used to evaluate the color stability with a spectrophotometer at baseline, after 1-7 days in dark dry storage at 37 °C, and after 1 day of artificial aging in water at 60 °C. Data were evaluated using 3-way ANOVA (flexural strength) and 4-way repeated measures ANOVA (color stability), followed by the Tukey's HSD test (α = .05). Flexural strength showed significant results for resin (p < .001), while manufacturing and post-curing methods were not significant (p > .05). The interaction effects between resin and manufacturing method (p = .978), and between resin, manufacturing method and post-curing method (p = .659) were not significant. In general, OnX showed higher flexural strength values than CB, regardless of manufacturing method or post-curing protocol. Color stability results showed significant results for resin (p < .001), time (p < .001), resin and time (p = .029), and resin and curing method (p < .001), but no differences considering resin and manufacturing mode (p = .87), or resin, manufacturing method and curing method (p = .35). In general, OnX showed a higher color change than CB, longer storage times resulted in increased color change for both materials, and CB cured with VG showed lower color alteration than CB cured with PC2. The manufacturing method (3D printed or not 3D printed) does not seem to influence the flexural strength and color stability of 3D printed resins. This may indicate that, at least from a physical-mechanical perspective, the final properties of the material are mainly dependent on the post-curing process.

2.
Int J Comput Dent ; 0(0): 0, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700085

RESUMO

AIM: The aim of this study was to evaluate the physical-mechanical behavior of the occlusal veneers when subjected to thermomechanical cycling. MATERIALS AND METHODS: Sixty specimens were divided into 04 groups (n=15 per group), according with the different restorative materials and thicknesses: material - lithium dissilicate LD (IPS e.max CAD, Ivoclar Vivadent) and nano- ceramic-resins NCR (ESPE Lava Ultimate, 3M); thickness - 0.6 and 1.2mm. The occlusal veneers were bonded over human flattened fresh extracted molars with dual-polymerizing luting agent (Variolink N, Ivoclar Vivadent and RelyX Ultimate 3M) using the respective adhesive system following the selective-etch technique (self-etch in dentin and total etch in enamel). The resin cement was light cured for 40 seconds each face, using a LED light cure equipment (BlueStar II, Microdont, 1100 mW/cm2). The response variables consisted of veneer survival rates (crack formation, catastrophic cracks and debonding) when subjected to thermal cycling from 5° to 55° C and simultaneous mechanical cycling performed at load intensities of 100, 200, 300, 400 and 450N for 20,000 cycles each. RESULT: Data were submitted to the Kruskall Wallis test and Pairwise Comparison, adopting a significance level of 5%. NCRs presented a lower incidence of failures (p<0.05) when compared to LD. According to thickness factor, 1.2mm thick occlusal veneers withstand higher cycling loads. CONCLUSION: NCR occlusal veneers with 1.2mm thickness presented superior physical-mechanical behavior than lithium disilicate and 0.6mm restorations.

3.
Odontology ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38797796

RESUMO

This research assessed the effects of pre-heating on the physical-mechanical-chemical properties of different resin composites. For this, resin composites were evaluated in 6 levels: Admira/ADM, Vitra/VIT, Filtek Supreme/FS, Filtek Supreme Flowable/FSF, Filtek One/FO, and Filtek Bulk Fill Flowable/FBF; temperature was evaluated in 4 levels using a composite heater: room temperature/22 ºC, 37 ºC, 54 ºC, and 68 ºC. Response variables were: degree of conversion/DC, flexural strength/FS and color stability/ΔE (immediately after light curing/LC, after 7 days of dark-dry-storage, and after 24 h and 3 days of artificial aging in water at 60 ºC). Data were subjected to 2-way ANOVA (DC and FR) and 3-way repeated measurements ANOVA (ΔE), all followed by Tukey's test (α = 5%). DC were similar (FBF, FS, and FSF) or increased (ADM, FO, and VIT) as the temperature increased. Results of FR were unchanged or increased for all composites except VIT and ADM. High-viscosity composites (VIT and FS) showed higher FR values than low-viscosity composite (FSF). For bulk-fill composites, FBF and FO showed similar results, but lower than high-viscosity composites. Results of color stability showed acceptable values up to 3 days aging except for ADM and FSF. ΔE was not influenced by pre-heating and, overall, ΔE: FS < VIT < FO < FSF < ADM < FBF. Only VIT and FS showed ΔE ≤ 3.3 (clinical threshold). Therefore, the effects of pre-heating depend on the material. The tested materials generally showed similar or enhanced properties after pre-heating (except ADM and VIT).

4.
Int J Prosthodont ; 37(7): 13-17, 2024 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-38489216

RESUMO

PURPOSE: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers. MATERIALS AND METHODS: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner. All data were exported in STL file format, processed, and sent to five 3D printers. Five casts were manufactured in each printer group: SG (CARES P20, Straumann); FG (Form 2, Formlabs); WG (Duplicator 7, Wanhao); ZG (Zenith D, Zenith); and MG (Moonray S100, Moonray). Measurements of the accuracy (trueness and precision) of the casts obtained from conventional elastomeric impressions and 3D-printing methods were accomplished using a 3D analysis software (Geomagic Control). RESULTS: The FG group showed the lowest values for trueness (indicating a value closer to real dimensions), which were similar to the SG group only (P > .05). MG, WG, and ZG groups presented higher values and were similar compared to each other. Data on precision demonstrated that all 3D-printed groups showed lower values for precision (smaller deviation) when compared to the CG. CONCLUSIONS: The trueness depends on the chosen 3D printer. All of the tested 3D printers were more precise than cast models obtained from conventional elastomeric impressions.


Assuntos
Desenho Assistido por Computador , Implantes Dentários , Impressão Tridimensional , Técnica de Moldagem Odontológica , Imageamento Tridimensional
6.
J Clin Exp Dent ; 15(6): e464-e469, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37388428

RESUMO

Background: The objective was to compare physic-mechanical properties of different materials used for temporary restorations. Material and Methods: Protemp 4/bisacrylic resin, Jet/acrylic resin, and Nexdent C&B/3D-printed resin samples (10mm diameter x 2mm thickness) were analyzed for surface roughness and color stability tests (baseline, after 5 thousand brushing cycles; and after artificial aging in water at 60oC for 24 hours) and Knoop microhardness. All data were checked for normality using Shapiro-Wilk test. Surface roughness and color stability were analyzed using two-way repeated measurements ANOVA, microhardness data was subjected to one-way ANOVA. All tests were followed by Tukey test and were performed with α=0.05. Results: For roughness, material (p=.002), time points (p=.002) and interaction between both (p<.001) were significant. All groups presented similar roughness for measurements of baseline and after brushing. After artificial aging, 3D printed resin showed decreased roughness when compared with other resins, and with its baseline reading. Acrylic resin showed an increase in surface roughness (when compared with measurement after brushing cycles). Considering color stability, only the material (p=.039) and the time (p<0.001) were significant. All groups showed similar color variation before and after artificial aging. There was an increase in color alteration after artificial aging for all groups. Considering microhardness test (p<.001), the 3D printed resin showed the highest values and acrylic resin the lowest. Bysacylic resin was similar to both 3D printed and acrylic resins. Conclusions: The tested 3D printed resins present similar or better properties than other tested temporary materials while being integrated with the digital workflow. Key words:Disinfection methods, hydroxyl radical, environment, surfaces, dentistry.

8.
J Dent Educ ; 87(6): 787-790, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36929470

RESUMO

BACKGROUND: The Commission on Dental Accreditation (CODA) was established in 1975 with the goal of serving the public and the dental profession by developing and implementing standards that guide and maintain the quality of dental educational programs. These standards are defined broadly around competencies reflective of an evidence-based definition of general dentistry and that should be met by the new graduates to function as an entry level provider. Consequently, CODA "expects each school to develop specific competency definitions and assessment methods in the context of the broad scope of general dental practice". CODA Standard 2-24 h was implemented a decade ago to address concerns that dental schools are not sufficiently proactive in incorporating implant-related curricula and clinical competencies. When the standard was implemented, most patients already preferred dental implants over FPDs. This market trend, together with the prescriptive format of the standard, had the unintended consequence of creating pressure on programs that struggled to find enough patients who will chose FPDs as a treatment option. DISCUSSION: As a short term solution, we suggest a tooth replacement competency construct that has the potential to alleviate this burden. This solution incorporates principles of ethical decision making, patient-centered care, and evidence-based dentistry, without compromising educational aspects and competency development. For the longer term, we suggested to revise and rephrase the standard so that it will be clinically-centered rather than focused on technical tools that may evolve, change, or disappear as a result of technological progress and other market trends. This, in turn, will be conducive to fulfill the intent of Standard 2-24 to allow the schools to identify "competencies that will be included in the curriculum based on the school's goals, resources, accepted general practitioner responsibilities and other influencing factors."


Assuntos
Acreditação , Currículo , Humanos
9.
J Prosthet Dent ; 129(2): 350-353, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34218898

RESUMO

STATEMENT OF PROBLEM: When 3-dimensional printing casts, the operator can change the type of resin and the printing layer thickness, reducing the fabrication time. However, how these parameters affect the accuracy of 3-dimensionally printed casts is unknown. PURPOSE: The purpose of this in vitro study was to evaluate the accuracy of 3-dimensionally printed casts by using a stereolithography (SLA) 3-dimensional printer (Forms2) with 3 different layer thickness (25, 50, and 100 µm) and 2 different resins (Gray and Cast) and by comparing the time to obtain each cast. MATERIAL AND METHODS: One master cast was scanned, and a single file was printed several times. The printed casts were then scanned by using a laboratory scanner. The standard tessellation language (STL) files provided by the laboratory scanner were superimposed and compared by using a software program (Geomagic Control; 3D Systems). The 2-way ANOVA test was used for the trueness evaluation, followed by the Tukey test to identify differences among the groups (α=.05). RESULTS: No statistically significant differences in accuracy were found among the 3 different layers for either resin (P>.05). Printing time doubled as layer thickness decreased. CONCLUSIONS: This study showed that when printing casts, the fastest printing settings can be used without losing accuracy and that the laboratory digital workflow can be accelerated with selection of the resin and cast layer, as the type of resin and layer thickness did not influence the quality of the casts.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Impressão Tridimensional , Estereolitografia , Software
10.
J Endod ; 49(1): 36-44, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36328250

RESUMO

INTRODUCTION: The aim of this study was to assess the temporal evolution of external cervical resorption (ECR) defects using a volumetric quantification method. METHODS: Cone-beam computed tomographic (CBCT) images of patients diagnosed with ECR who chose not to receive treatment and attended recalls were collected. ECR defects were segmented in CBCT images at baseline and recall, and their volumes were quantified. The volumetric ratio of resorption defects/teeth was calculated. Three-dimensional classification of defects at baseline and recall and the prevalence of root surface perforations ≥1 mm were determined. The Wilcoxon matched pairs signed rank test, chi-square test, and linear regression models were used to analyze the data. RESULTS: Fifteen patients with 20 teeth diagnosed with ECR and an average recall time of 21 months were included. Nine (45%) teeth showed a change in 3-dimensional classification at recall. The volume of resorption defects (P = .0001) and the volumetric ratio of resorption defects/teeth (P = .0001) increased over time. The prevalence of root surface perforations ≥1 mm was higher at recall (n = 17, 85%) compared with baseline (n = 9, 45%) (P = .008). Linear regression models showed significant associations between the resorption defect volume at recall compared with baseline (P < .0001; 95% confidence interval, 0.053-0.081) and the volumetric ratio of resorption defects/teeth at recall compared with baseline (P < .0001; 95% confidence interval, 0.205-0.356). There was no association between the volume of resorption defects at recall with the length of the recall period, sex, or age (P > .05). CONCLUSIONS: When left untreated, ECR defects can increase in size and develop more root surface perforations. ECR has a dynamic nature, and its volumetric increase over time does not result from uniform/linear expansion of the defects.


Assuntos
Reabsorção da Raiz , Reabsorção de Dente , Dente , Humanos , Reabsorção da Raiz/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Colo do Dente/diagnóstico por imagem
11.
Int J Prosthodont ; 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36484676

RESUMO

PURPOSE: To evaluate and compare the accuracy of conventional and 3D-printed casts using five different 3D printers. MATERIALS AND METHODS: In the control group (CG group, n = 5), five conventional impressions using light- and heavy-body polyvinyl siloxane were obtained from the master model, resulting in five stone models. In the test groups, five different scans were performed by a well-trained and experienced clinician using a TRIOS intraoral scanner. All data were exported as an STL file format, processed, and sent to five 3D printers. Five casts were manufactured in each group: SG (CARES P20, Straumann); FG (Form 2, Formlabs); WG (Duplicator 7, Wanhao); ZG (Zenith D, Zenith); and MG (Moonray S100, Moonray). Measurements of the accuracy (trueness and precision) of the casts obtained from conventional elastomeric impressions and 3D-printing methods were accomplished using a 3D analysis software (Geomagic Control). RESULTS: The FG group showed the lowest values for trueness (closer to real dimensions), which were similar to the SG group only (P > .05). Groups MG, WG, and ZG presented higher values and were similar compared to each other. Data on precision demonstrated that all 3D-printed groups showed lower values for precision (smaller deviation) when compared to the control group. CONCLUSION: The trueness depends on the chosen 3D printer. All of the tested 3D printers were more precise than cast models obtained from conventional elastomeric impressions.

12.
J Prosthet Dent ; 128(5): 1102.e1-1102.e5, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36460427

RESUMO

STATEMENT OF PROBLEM: Postpolymerization methods influence the properties of 3-dimensionally (3D) printed materials. Nevertheless, it is a time-consuming step that could lead dentists to avoid the chairside use of 3D printing. Information assessing the impact of different postpolymerization workflows on flexural strength and color stability is sparse. PURPOSE: The purpose of this in vitro study was to analyze the impact of different postpolymerization methods on the flexural strength and color stability of 3D-printed resins used for interim restorations. MATERIAL AND METHODS: Three resin materials: CT (Cosmos Temp; Yller Biomaterials), DT (Denture Teeth; Formlabs), and CB (C&B MFH; NextDent) were submitted to 4 methods of postpolymerization: a Form Cure polymerization chamber (FC) (Form Cure; Formlabs), a broadband LED device (Valo Grand; Ultradent Products, Inc) operating at 1000 mW/cm2 for 2 different polymerization times (40 seconds/V40 or 120 seconds/V120), and a custom-made polymerization chamber with a 24 W UV LED Strip (CC). The specimens were assessed for flexural strength using an universal testing machine immediately after polymerization or after 10 000 thermal cycles, and the color stability was evaluated using a spectrophotometer at baseline, after 7 days in dark, dry storage at 37 °C and after 24 hours of artificial aging in water at 60 °C. The data were evaluated using 3-way ANOVA (flexural strength) and 3-way repeated measurements ANOVA (color stability), followed by the Tukey HSD test (α=.05). RESULTS: Flexural strength showed significant differences for resin, postpolymerization method, time, and for the interaction between all effects. CT showed the highest overall flexural strength, while DT showed the lowest. In general, V120 produced specimens with higher flexural strength. Thermocycling did not reduce flexural strength except for CB polymerized with FC and V120, and DT polymerized with V40. For color stability, significant differences were found for resin, postpolymerized method, time, and for the interaction between all effects. The highest ΔE values were observed for DT polymerized using V40 after artificial aging. The lowest values were observed for the same resin but polymerized using V120 after 7 days in dark, dry storage at 37 °C. CONCLUSIONS: Postpolymerization with the broadband LED device for 120 seconds can produce specimens with higher flexural strength values and higher color stability when compared with the other postpolymerization workflows tested in this study.


Assuntos
Resistência à Flexão , Projetos de Pesquisa , Polimerização , Materiais Biocompatíveis , Impressão Tridimensional
13.
Dent Mater ; 38(8): e220-e230, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35750506

RESUMO

OBJECTIVE: This study evaluated the microshear bond strength of a resin cement to Y-TZP after different methods of TiO2 nanotubes (nTiO2) incorporation on pre-sintered Y-TZP surfaces. METHODS: nTiO2 were synthesized and incorporated on Y-TZP slices as follows (n = 15): 1) nTiO2 mixed with isopropyl alcohol/manual application (MAl); 2) nTiO2 mixed with acetone/manual application (MAc); 3) nTiO2 mixed with isopropyl alcohol/high-pressure vacuum application (HPVAl); 4) nTiO2 mixed with acetone/high-pressure vacuum application (HPVAc). As controls, surfaces were sandblasted with Al2O3 (OX) or Rocatec silicatization (ROC). All ceramics were sintered after nTiO2 incorporation. Surface treatments of OX and ROC were made after sintering. Surfaces were characterized by confocal laser microscopy, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). Resin composite cylinders (1.40 mm diameter and 1 mm height) were cemented with a resin cement, stored in water at 37 °C for 24 h and thermocycled for 10 000 cycles before microshear bond strength evaluation. Data were analyzed with one-way ANOVA and Games-Howell (α = 0.05), and fracture analysis was performed using a stereomicroscope. RESULTS: EDS confirmed the presence of TiO2 on treated Y-TZP. The confocal analysis showed higher roughness for HPVAc and OX. There were significant differences between surface treatments (p < 0.001). HPVAl (22.96 ± 10.3), OX (34.16 ± 7.9) and ROC (27.71 ± 9.4) showed higher microshear bond strengths and were statistically similar (p > 0.05). MAC showed intermediary values, and HPVAc and MAl presented decreased bond strength, with a high percentage of premature debonding. CONCLUSION: High-pressure vacuum application of nTiO2 mixed with isopropyl alcohol was able to produce bond strength values compared to conventional air abrasion and Rocatec silicatization. SIGNIFICANCE: The infiltration of TiO2 nanostructures on the pre-sintered Y-TZP is an interesting approach that can improve bond strength without the need of sandblasting methods.


Assuntos
Colagem Dentária , Nanotubos , 2-Propanol , Acetona , Abrasão Dental por Ar , Colagem Dentária/métodos , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de Superfície , Titânio , Ítrio/química , Zircônio/química
14.
J Clin Exp Dent ; 14(4): e366-e370, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35419173

RESUMO

Background: Proanthocyanidin has been considered as a preventive agent against erosion because of its properties, which involves remineralization, reduction of demineralization and matrix metalloproteinases (MMPs) inhibition. Thus, the aim of this in situ study was to evaluate the effect of proanthocyanidin-based dentifrices on wear resistance of dentin specimens subjected to erosion associated with abrasion. Material and Methods: This crossover double-blinded study was performed in 5 phases of 5 days each, with 10 healthy volunteers who wore 5 palatal devices (1 for each phase) with 4 dentin specimens. The groups under study were: G1 - placebo dentifrice (negative control group); G2 - 0.012% chlorhexidine dentifrice (1st positive control group); G3 - NaF 1110 ppm fluoride dentifrice (2nd positive control group); G4 - 10% purified proanthocyanidin dentifrice (1st test group); G5 - fluoride + proanthocyanidin dentifrice (2nd test group). Erosion was performed by palatal device immersion in acid beverage (Coca-cola®), 3 times daily for 5 minutes during 5 days. Abrasion was applied after the first and third erosive cycles by using a eletric toothbrush during 15 seconds in each specimen with the application of the studied dentifrices slurry. The response variable was depth of dentin loss (µm) measured by profilometry. Data were analyzed by Repeated Measures Analysis of Variance followed by LSD Fisher's test (p<0.05). Results: Data (G1: 1.76 ± 0.55A; G2: 1.19 ± 0.42B; G3: 1.29 ± 0.34B; G4: 0.93 ± 0.38C; G5: 0.82 ± 0.34C) showed that G4 and G5 did not presented significant difference between them, but showed less dentine loss when compared to all other groups. G1 presented the highest dentin wear. Conclusions: Proanthocyanidin and the combination of proanthocyanidin and fluoride dentifrices revealed the best results, showing that these formulations could be a promising alternative for patients who suffer with dentin erosion. Key words:Dentin, erosion, cross-liking agent, metalloproteinases, toothpastes.

15.
Orthod Craniofac Res ; 25(3): 429-436, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34863033

RESUMO

INTRODUCTION: Patients with Class II subdivision malocclusion present skeletal and dental asymmetries. The purpose of this study is to assess those asymmetries by 3D mirroring and colormap quantification. METHODS: This study analyzed 50 initial CBCTs divided into two groups: Class I (control group) and Class II subdivision (study group) malocclusion patients. CBCTs were oriented and full skull was segmented generating a 3D model. The right side of the 3D models was mirrored, using a midsagittal plane as reference, resulting in a perfectly symmetric skull based on two right sides. Original and mirrored models were superimposed on the unchanged right half, and differences were quantified using a colormap. Eight regions of interest were assessed: gonion, mandibular front, maxillary front, zygomatic process, maxillary and mandibular canine and molar areas. RESULTS: Statistically significant differences using the Mann-Whitney test were found in six of the eight evaluated areas when comparing the control to the study group. The maxillary skeletal areas did not show any difference between the groups. CONCLUSIONS: Patients with Class II subdivision malocclusion show true skeletal and dental asymmetries when comparing right and left sides. The maxilla showed no significant skeletal asymmetry, but the maxillary teeth were positioned more mesially on the Class II side. The maxillary canine on the Class II side was also more bucally positioned. The mandible showed significant asymmetries with both skeletal and dental areas in the Class II side more distally and bucally positioned.


Assuntos
Má Oclusão Classe II de Angle , Má Oclusão , Cefalometria/métodos , Dente Canino , Assimetria Facial , Humanos , Mandíbula , Maxila
16.
J Biomed Mater Res A ; 110(3): 696-707, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34672417

RESUMO

Endosseous implant surface topography directly affects adherent cell responses following implantation. The aim of this study was to examine the impact of nanoscale topographic modification of titanium implants on Osterix gene expression since this gene has been reported as key factor for bone formation. Titanium implants with smooth and nanoscale topographies were implanted in the femurs of Osterix-Cherry mice for 1-21 days. Implant integration was evaluated using scanning electron microscopy (SEM) to evaluate cell adhesion on implant surfaces, histology, and nanotomography (NanoCT) to observe and quantify the formed bone-to-implant interface, flow cytometry to quantify of Osterix expressing cells in adjacent tissues, and real-time PCR (qPCR) to quantify the osteoinductive and osteogenic gene expression of the implant-adherent cells. SEM revealed topography-dependent adhesion of cells at early timepoints. NanoCT demonstrated greater bone formation at nanoscale implants and interfacial osteogenesis was confirmed histologically at 7 and 14 days for both smooth and nanosurface implants. Flow cytometry revealed greater numbers of Osterix positive cells in femurs implanted with nanoscale versus smooth implants. Compared to smooth surface implants, nanoscale surface adherent cells expressed higher levels of Osterix (Osx), Alkaline phosphatase (Alp), Paired related homeobox (Prx1), Dentin matrix protein 1 (Dmp1), Bone sialoprotein (Bsp), and Osteocalcin (Ocn). In conclusion, nanoscale surface implants demonstrated greater bone formation associated with higher levels of Osterix expression over the 21-day healing period with direct evidence of surface-associated gene regulation involving a nanoscale-mediated osteoinductive pathway that utilizes Osterix to direct adherent cell osteoinduction.


Assuntos
Implantes Dentários , Osseointegração , Animais , Camundongos , Osteogênese , Próteses e Implantes , Propriedades de Superfície , Titânio/farmacologia
17.
Int J Oral Maxillofac Implants ; 36(4): 650-659, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34411204

RESUMO

PURPOSE: To evaluate whether a hydrophilic surface treatment compared with a hydrophobic implant surface can enhance osseointegration by analysis of calcium deposition, bone-to-implant contact (BIC), bone volume (BV), and upregulation of genes involved in bone formation. MATERIALS AND METHODS: Sixty implants (n = 60) with a hydrophobic (SAE) or hydrophilic (SAE-HD) surface treatment were placed bilaterally in each femur of 3-month-old male mice (n = 30). Scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS) were utilized for quantifying the presence of calcium on the implant surface 7 days after implant placement. The specimens were analyzed after 14 and 21 days for BIC and BV by Nano CT scanning followed by histologic evaluation. Additionally, 1, 3, and 7 days postsurgery, femurs were harvested, implants were explanted, and gene expression (Sp7, Bsp, Sost, IL-1α, and IL-10) by quantitative real-time polymerase chain reaction was studied. Moreover, implants were characterized for surface roughness area. Data were statistically analyzed with two-way analysis of variance (ANOVA) followed by the Tukey test (P < .05). RESULTS: The amount of calcium on the surface was higher for SAE-HD after 7 days. Nano CT revealed significantly more BV in the SAE-HD than the SAE surface. The histologic assessment showed increased BIC in SAE-HD in comparison to SAE. SAEHD showed significantly increased levels of genes involved in bone formation. CONCLUSION: Both surfaces were able to modulate bone responses toward osteoblast differentiation. SAE-HD presented a better response compared with SAE.


Assuntos
Implantes Dentários , Titânio , Animais , Implantes Experimentais , Masculino , Camundongos , Microscopia Eletrônica de Varredura , Osseointegração , Propriedades de Superfície
18.
J Periodontal Res ; 56(2): 351-362, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33368275

RESUMO

OBJECTIVE: Using a mouse osteoporotic model, this study aimed to determine the influence of hydrophilic titanium surfaces on gene expression and bone formation during the osseointegration process. BACKGROUND: Based on the previous evidence, it is plausible to assume that osteoporotic bone has a different potential of bone healing. Therefore, implant surface modification study that aims at enhancing bone formation to further improve short- and long-term clinical outcomes in osteoporosis is necessary. MATERIAL AND METHODS: Fifty female, 3-month-old mice were included in this study. Osteoporosis was induced by ovariectomy (OVX, test group) in 25 mice. The further 25 mice had ovaries exposed but not removed (SHAM, control group). Seven weeks following the ovariectomy procedures, one customized implant (0.7 × 8 mm) of each surface was placed in each femur for both groups. Implants had either a hydrophobic surface (SAE) or a hydrophilic treatment surface (SAE-HD). Calcium (Ca) and phosphorus (P) content was measured by energy-dispersive X-ray spectroscopy (EDS) after 7 days. The femurs were analyzed for bone-to-implant contact (BIC) and bone volume fraction (BV) by nano-computed tomography (nano-CT) after 14 and 28 days. Same specimens were further submitted to histological analysis. Additionally, after 3 and 7 days, implants were removed and cells were collected around the implant to access gene expression profile of key osteogenic (Runx2, Alp, Sp7, Bsp, Sost, Ocn) and inflammatory genes (IL-1ß, IL-10, Tnf-α, and Nos2) by qRT-PCR assay. Statistical analysis was performed by ANOVA and paired t test with significance at P < .05. RESULTS: The amount of Ca and P deposited on the surface due to the mineralization process was higher for SAE-HD compared to SAE on the intra-group analysis. Nano-CT and histology revealed more BV and BIC for SAE-HD in SHAM and OVX groups compared to SAE. Analysis in OVX group showed that most genes (ie, ALP, Runx2) involved in the bone morphogenetic protein (BMP) signaling were significantly activated in the hydrophilic treatment. CONCLUSION: Both surfaces were able to modulate bone responses toward osteoblast differentiation. SAE-HD presented a faster response in terms of bone formation and osteogenic gene expression compared to SAE. Hydrophilic surface in situations of osteoporosis seems to provide additional benefits in the early stages of osseointegration.


Assuntos
Implantes Dentários , Osteoporose , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Humanos , Osseointegração , Osteoporose/genética , Ovariectomia , Propriedades de Superfície , Titânio
19.
J Prosthet Dent ; 125(2): 294-299, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32115221

RESUMO

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear. PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs. MATERIAL AND METHODS: Three operators with low, medium, and high levels of experience scanned a master model 10 times by using 2 IOSs (CEREC Omnicam; Dentsply Sirona and TRIOS 3; 3Shape), resulting in 10 standard tessellation language files for each group (N=60). Each standard tessellation language file was divided into 2 areas (prepared teeth and complete arch). Precision was evaluated by comparing the 10 scans from each examiner for each system. Trueness was evaluated by comparing each scan file with a reference scan obtained from a laboratory scanner (D2000; 3Shape). A 3D analysis software program (Geomagic Control; 3D Systems) was used to perform all the comparisons and superimpositions. The 3-way ANOVA test followed by the Tukey HSD test were used to assess precision and trueness. The 2-way ANOVA followed by the Tukey HSD test was used to assess scan time. The Pearson correlation test was performed between scan time and trueness for both scanners. An additional correlation was performed between scan time and number of images, as well as between number of images and trueness for the TRIOS 3. RESULTS: Statistically significant influences of operator (P<.001), scanner (P<.001), scan size (P<.001), operator and scan size (P<.001), and scanner and scan size (P<.001) were observed. The TRIOS 3 group reported higher precision than the CEREC Omnicam group for complete-arch scans (P<.001), although no difference was observed for scans of the prepared tooth. Medium- (P=.002) and low-experience operators (P<.001) reported lower precision for complete-arch scans performed with CEREC Omnicam when compared with TRIOS 3. The low-experience operator reported significantly worse results for complete-arch scans in comparison with the medium- (P=.008 and P<.001) and high-experience operators (P<.001 and P=.001), by using TRIOS 3 and CEREC Omnicam, respectively. Medium- and high-experience operators reported similar results among themselves. The CEREC Omnicam scanner reported lower trueness for complete-arch scans when compared with the prepared tooth (P<.001); for TRIOS 3, a difference was only observed for the low-experience operator when compared with the high-experience operator (P<.001). The CEREC Omnicam reported lower trueness than the TRIOS 3, except for the medium-experience operator with the prepared tooth scan. Comparing the trueness between operators and considering the same scanner and scan size, all groups were similar. The low-experience operator had a longer scanning time than the medium- and high-experience operators. For TRIOS 3, the low-experience operator obtained the highest number of images during each scan. CONCLUSIONS: The accuracy of intraoral scans was influenced by operator experience, type of IOSs, and scan size. More experienced operators and smaller scan sizes made for more accurate scans. In addition, more experienced operators made faster scans, and the TRIOS 3 was more accurate than the CEREC Omnicam for complete-arch scans.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Arco Dental , Imageamento Tridimensional
20.
J Clin Exp Dent ; 12(9): e852-e856, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32994874

RESUMO

BACKGROUND: The aim of the present study was to compare indirect methods to assess the clinical performance of pit and fissure sealants and validate the use of 3D scanners. MATERIAL AND METHODS: Sample consisted of 58 plaster models of upper and lower first permanent molars, sealed with resin sealants, as well as photographs obtained during the 18-month follow-up. Pre-established criteria were applied to categorize the sealant presence/absence and marginal integrity. Two calibrated examiners performed the evaluations, independently, using Scanning Electron Microscopy (SEM; gold-standard), Photography, 3D (CEREC In Lab) and Stereomicroscope analysis. RESULTS: The intra-examiner Spearman correlation was 94% e 97%, respectively, and the inter-examiner was 96%. Data was submitted to Kappa test, Spearman correlation and Receiver Operating Characteristic Curve (ROC). 3D and SEM presented good concordance; Stereomicroscope showed regular concordance with SEM and 3D (p<0.001). There was no concordance among Photography and the other methods (p>0.05). SEM had a significant positive correlation with 3D and Stereomicroscope (r=0.76 and 0.71, respectively; p<0.01). There was significant positive correlation (r=0.65) between 3D and Stereomicroscope (p<0.01). The ROC estimated curve areas for Stereomicroscope and 3D were 0.90 (IC:0.81-0.99) and 1.0 (IC:1.0-1.0), respectively (p<0.001). CONCLUSIONS: Photography presented lower sensitivity and specificity (area=0.59). 3D method showed the best performance when compared to gold standard, exhibiting high sensitivity and specificity, therefore, it was validated as a reliable method to evaluate pit and fissure sealants. Key words:Photography, stereomicroscope, SEM, diagnostic, sealants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA