1.
ASAIO J ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38728744

RESUMO

The Pulmonary Assist System (PAS) is currently under development as a wearable respiratory assist system. In this study, the hemocompatibility of the PAS's axial-flow mechanical pump (AFP) was compared to other contemporary mechanical pumps in an acute ovine model. The PAS was attached to a normal sheep in a venovenous configuration using one of three pumps: 1) AFP, 2) ReliantHeart HeartAssist 5 (control), or 3) Abbott Pedimag (control) (n = 5 each). Each sheep was supported on the PAS for 12 hours with two L/minute of blood flow and four L/minute of sweep gas. Hemolysis, coagulation, inflammation, and platelet activation and loss were compared among the groups. In this study, the plasma-free hemoglobin (pfHb) was less than 10 mg/dl in all groups. The pfHb was significantly lower in the AFP group compared to other groups. There was no significant clot formation in the pumps and oxygenators in all groups. Furthermore, no significant differences in coagulation (oxygenator resistance, fibrinopeptide A), inflammation (white blood cell counts, IL-8), and platelet activation and loss (p-selectin, platelet counts) were observed among the groups (all, p > 0.05). This study demonstrates equivalent hemocompatibility of the PAS's AFP to other contemporary mechanical pumps with a reduced level of hemolysis on startup.

2.
ASAIO J ; 70(2): e23-e26, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37578993

RESUMO

A new, lightweight (2.3 kg), ambulatory pulmonary assist system (PAS) underwent preliminary evaluation in ambulatory sheep. The PAS was purposefully designed for long-term extracorporeal respiratory support for chronic lung disease and utilizes a novel, small (0.9 m 2 surface area) gas exchanger, the pulmonary assist device, with a modified Heart Assist 5 pump fitting in a small wearable pack. Prototype PAS were attached to two sheep in venovenous configuration for 7 and 14 days, evaluating ability to remain thrombus free; maintain gas exchange and blood flow resistance; avoid biocompatibility-related complications while allowing safe ambulation. The PAS achieved 1.56 L/min of flow at 10.8 kRPM with a 24 Fr cannula in sheep one and 2.0 L/min at 10.5 kRPM with a 28 Fr cannula in sheep 2 without significant change. Both sheep walked freely, demonstrating the first application of truly ambulatory ECMO in sheep. While in vitro testing evaluated PAS oxygen transfer rates of 104.6 ml/min at 2 L/min blood flow, oxygen transfer rates averaged 60.6 ml/min and 70.6 ml/min in studies 1 and 2, due to average hemoglobin concentrations lower than humans (8.9 and 10.5 g/dl, respectively). The presented cases support uncomplicated ambulation using the PAS.


Assuntos
Pneumopatias , Pulmão , Humanos , Ovinos , Animais , Hemodinâmica/fisiologia , Oxigênio , Cânula
3.
ASAIO J ; 69(6): 527-532, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728837

RESUMO

Heparin anticoagulation increases the bleeding risk during extracorporeal life support (ECLS). This study determined whether factor XII (FXII) silencing using short interfering RNA (siRNA) can provide ECLS circuit anticoagulation without bleeding. Adult male, Sprague-Dawley rats were randomized to four groups (n = 3 each) based on anticoagulant: (1) no anticoagulant, (2) heparin, (3) FXII siRNA, or (4) nontargeting siRNA. Heparin was administered intravenously before and during ECLS. FXII or nontargeting siRNA were administered intravenously 3 days before the initiation of ECLS via lipidoid nanoparticles. The rats were placed on pumped, arteriovenous ECLS for 8 hours or until the blood flow resistance reached three times its baseline resistance. Without anticoagulant, mock-oxygenator resistance tripled within 7 ± 2 minutes. The resistance in the FXII siRNA group did not increase for 8 hours. There were no significant differences in resistance or mock-oxygenator thrombus volume between the FXII siRNA and the heparin groups. However, the bleeding time in the FXII siRNA group (3.4 ± 0.6 minutes) was significantly shorter than that in the heparin group (5.5 ± 0.5 minutes, p < 0.05). FXII silencing using siRNA provided simpler anticoagulation of ECLS circuits with reduced bleeding time as compared to heparin. http://links.lww.com/ASAIO/A937.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Masculino , Ratos , Anticoagulantes , Fator XII/genética , Heparina , Ratos Sprague-Dawley , RNA Interferente Pequeno/genética , Trombose/etiologia , Trombose/prevenção & controle
4.
Biomaterials ; 272: 120778, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33812214

RESUMO

Blood contact with high surface area medical devices, such as dialysis and extracorporeal life support (ECLS), induces rapid surface coagulation. Systemic anticoagulation, such as heparin, is thus necessary to slow clot formation, but some patients suffer from bleeding complications. Both problems might be reduced by 1) replacing heparin anticoagulation with artificial surface inhibition of the protein adsorption that initiates coagulation and 2) selective inhibition of the intrinsic branch of the coagulation cascade. This approach was evaluated by comparing clot formation and bleeding times during short-term ECLS using zwitterionic polycarboxybetaine (PCB) surface coatings combined with either a potent, selective, bicyclic peptide inhibitor of activated Factor XII (FXII900) or standard heparin anticoagulation. Rabbits underwent venovenous ECLS with small sham oxygenators for 60 min using three means of anticoagulation (n = 4 ea): (1) PCB coating + FXII900 infusion, (2) PCB coating + heparin infusion with an activated clotting time of 220-300s, and (3) heparin infusion alone. Sham oxygenator blood clot weights in the PCB + FXII900 and PCB + heparin groups were 4% and 25% of that in the heparin group (p < 10-6 and p < 10-5), respectively. At the same time, the bleeding time remained normal in the PCB + FXII900 group (2.4 ± 0.2 min) but increased to 4.8 ± 0.5 and 5.1 ± 0.7 min in the PCB + heparin and heparin alone groups (p < 10-4 and 0.01). Sham oxygenator blood flow resistance was significantly lower in the PCB + FXII900 and PCB + heparin groups than in the heparin only group (p < 10-6 and 10-5). These results were confirmed by gross and scanning electron microscopy (SEM) images and fibrinopeptide A (FPA) concentrations. Thus, the combined use of PCB coating and FXII900 markedly reduced sham oxygenator coagulation and tissue bleeding times versus the clinical standard of heparin anticoagulation and is a promising anticoagulation method for clinical ECLS.


Assuntos
Anticoagulantes/farmacologia , Oxigenação por Membrana Extracorpórea , Fator XII/antagonistas & inibidores , Animais , Betaína , Coagulação Sanguínea , Heparina/farmacologia , Humanos , Ácidos Polimetacrílicos , Coelhos , Diálise Renal
5.
J Transl Med ; 19(1): 179, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33910585

RESUMO

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) research using large animals requires a significant amount of resources, slowing down the development of new means of ECMO anticoagulation. Therefore, this study developed and evaluated a new rat ECMO model using a 3D-printed mock-oxygenator. METHODS: The circuit consisted of tubing, a 3D-printed mock-oxygenator, and a roller pump. The mock-oxygenator was designed to simulate the geometry and blood flow patterns of the fiber bundle in full-scale oxygenators but with a low (2.5 mL) priming volume. Rats were placed on arteriovenous ECMO at a 1.9 mL/min flow rate at two different heparin doses (n = 3 each): low (15 IU/kg/h for eight hours) versus high (50 IU/kg/h for one hour followed by 25 IU/kg/h for seven hours). The experiment continued for eight hours or until the mock-oxygenator failed. The mock-oxygenator was considered to have failed when its blood flow resistance reached three times its baseline resistance. RESULTS: During ECMO, rats maintained near-normal mean arterial pressure and arterial blood gases with minimal hemodilution. The mock-oxygenator thrombus weight was significantly different (p < 0.05) between the low (0.02 ± 0.006 g) and high (0.003 ± 0.001 g) heparin delivery groups, and blood flow resistance was also larger in the low anticoagulation group. CONCLUSIONS: This model is a simple, inexpensive system for investigating new anticoagulation agents for ECMO and provides low and high levels of anticoagulation that can serve as control groups for future studies.


Assuntos
Oxigenação por Membrana Extracorpórea , Trombose , Animais , Heparina/farmacologia , Oxigenadores , Impressão Tridimensional , Ratos
6.
Nat Commun ; 11(1): 3890, 2020 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-32753636

RESUMO

Inhibiting thrombosis without generating bleeding risks is a major challenge in medicine. A promising solution may be the inhibition of coagulation factor XII (FXII), because its knock-out or inhibition in animals reduced thrombosis without causing abnormal bleeding. Herein, we have engineered a macrocyclic peptide inhibitor of activated FXII (FXIIa) with sub-nanomolar activity (Ki = 370 ± 40 pM) and a high stability (t1/2 > 5 days in plasma), allowing for the preclinical evaluation of a first synthetic FXIIa inhibitor. This 1899 Da molecule, termed FXII900, efficiently blocks FXIIa in mice, rabbits, and pigs. We found that it reduces ferric-chloride-induced experimental thrombosis in mice and suppresses blood coagulation in an extracorporeal membrane oxygenation (ECMO) setting in rabbits, all without increasing the bleeding risk. This shows that FXIIa activity is controllable in vivo with a synthetic inhibitor, and that the inhibitor FXII900 is a promising candidate for safe thromboprotection in acute medical conditions.


Assuntos
Anticoagulantes/farmacologia , Coagulação Sanguínea/efeitos dos fármacos , Fator XIIa/antagonistas & inibidores , Peptídeos Cíclicos/efeitos dos fármacos , Trombose/prevenção & controle , Animais , Cloretos/efeitos adversos , Clonagem Molecular , Modelos Animais de Doenças , Descoberta de Drogas , Oxigenação por Membrana Extracorpórea/métodos , Fator XII/antagonistas & inibidores , Feminino , Compostos Férricos/efeitos adversos , Humanos , Pulmão , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Coelhos , Proteínas Recombinantes/farmacologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...