2.
Adv Ther ; 35(5): 666-670, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29730835

RESUMO

INTRODUCTION: Insulation failure leading to conductor externalization (CE) of a Linox (Biotronik, Berlin, Germany) implantable cardioverter defibrillator (ICD) lead has recently been reported. The aim of this study was to assess prospectively all Linox family ICD leads implanted at our center for evidence of CE or an electrical abnormality. METHODS: All patients with a Linox family ICD lead implanted at our center, between November 2007 and March 2015, were identified and all living patients were invited to attend for fluoroscopic screening and electrical assessment of the lead. RESULTS: A total of 183 patients had a Linox family ICD lead implanted at our center. Of these, 5 patients (2.7%) had the lead extracted because of electrical failure and 2 of these leads had evidence of CE. Out of 158 living patients with a Linox family ICD lead, 111 patients attended for screening (mean age 63.1 years, 22.5% female). In this group of patients, no cases of CE or electrical abnormalities of the lead were identified. CONCLUSION: In this study evaluating 183 patients with a Linox family ICD lead implanted at a single center, 5 leads (2.7%) were explanted because of electrical failure and 2 of these leads had evidence of CE. Prospective fluoroscopic assessment of 111 Linox family ICD leads, with a mean dwell time of 31.5 months, revealed no further cases of CE.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Análise de Falha de Equipamento , Falha de Equipamento , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/normas , Desfibriladores Implantáveis/estatística & dados numéricos , Fenômenos Eletromagnéticos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reino Unido
4.
Pacing Clin Electrophysiol ; 37(11): 1538-43, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25081476

RESUMO

BACKGROUND: Insulation defects resulting in conductor externalization (CE) have been reported in the Riata family of implantable cardioverter defibrillator (ICD) leads (St. Jude Medical, Sylmar, CA, USA). The aim of this study was to identify, prospectively, the rate of CE and outcomes following this, within a group of patients with a Riata ICD lead. METHODS: Patients with a Riata ICD lead attended for fluoroscopic screening and electrical assessment of the lead at yearly intervals between 2010 and 2012. RESULTS: One hundred and forty patients had no or borderline evidence of CE on initial assessment in 2010. These patients were prospectively followed for 3 years (304.6 patient-years). During this time, 11 patients developed definite CE, equating to an event rate of 3.6 (95% confidence intervals: 1.8-6.5) per 100 patient-years of follow-up. Of those patients developing definite CE, one patient had the ICD lead explanted (for reasons unrelated to CE) and no patients died. CE was not associated with any electrical abnormalities of the ICD lead. CONCLUSIONS: CE was observed at a rate of 3.6 per 100 patient-years of follow-up, in 140 individuals with a Riata ICD lead and no definite evidence of CE at baseline.


Assuntos
Desfibriladores Implantáveis , Falha de Prótese , Idoso , Eletrodiagnóstico , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Pacing Clin Electrophysiol ; 35(12): 1498-504, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23035735

RESUMO

INTRODUCTION: Insulation defects with externalized conductors have been reported in the St. Jude Riata(®) family of defibrillation leads (St. Jude Medical, Sylmar, CA, USA). The objective of the Northern Ireland Riata(®) lead screening program was to identify insulation defects and externalized conductors by systematic fluoroscopic and electrical assessment in a prospectively defined cohort of patients. We sought to estimate the prevalence, identify risk factors, and determine the natural history of this abnormality. METHODS: All patients with a Riata(®) lead under follow-up at the Royal Victoria Hospital were invited for fluoroscopic imaging and implantable cardioverter-defibrillator lead parameter checks. Fluoroscopic images were read independently by two cardiologists and the presence of externalized conductors was classified as positive, negative, or borderline. RESULTS: One hundred and sixty-five of 212 patients with a Riata lead were evaluated by fluoroscopy and lead parameter measurements. The mean duration after implantation was 3.98+/-1.43 years. After screening 25 (15%) patients were classified as positive, 137 (83%) negative, and three (1.8%) borderline. Time since implantation (P = 0.001), presence of a single coil lead (P = 0.042), and patient age (P = 0.034) were significantly associated with externalized conductors. The observed rate of externalized conductors was 26.9% for 8-French and 4.7% for 7-French leads. No leads that were identified prospectively with externalized conductors had electrical abnormalities. Seven of 25 (28%) patients had a defective lead extracted by the end of this screening period. CONCLUSION: A significant proportion (15%) of patients with a Riata lead had an insulation breach 4 years after implantation. High-resolution fluoroscopic imaging in at least two orthogonal views is required to identify this abnormality.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados , Análise de Falha de Equipamento , Falha de Equipamento/estatística & dados numéricos , Fluoroscopia/métodos , Idoso , Distribuição de Qui-Quadrado , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Electrocardiol ; 40(6 Suppl): S111-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17993307

RESUMO

BACKGROUND: Noncontact endocardial mapping allows accurate beat-to-beat reconstruction of the reentrant pathway of ventricular tachycardia and improves outcomes after ablation. Several studies support electrocardiographic imaging (ECGI) as a means of noninvasively outlining epicardial activation despite constraints of internal geometry. However, few have explored its clinical application. This study aims to evaluate ECGI during selective left ventricular (LV) pacing, relative to an invasive approach. METHODS: Multisite pacing was performed within the left ventricles of 3 patients undergoing invasive procedures. Simultaneous recording of endocardial potentials using a noncontact multielectrode array and body surface potentials (BSP) using an 80-electrode torso vest was performed. A total of 16 recordings were made. The inverse solution was applied to BSP to reconstruct epicardial activation. Single-paced beats from real and virtual electrograms were used to construct 3-dimensional isochronal and isopotential maps. Endocardial and epicardial data were then superimposed onto a single geometry to allow quantitative comparison of activation foci. RESULTS: Good correlation was observed between endocardial activation patterns and those reconstructed from BSP using ECGI. This was repeatedly demonstrated in all LV regions except for the septum (3 recordings). Epicardial isochronal maps were able to locate early and late activation to mean distances of 13.8 +/- 4.7 and 12.5 +/- 3.7 mm from endocardial data. Isopotential maps localized pacing sites with comparable accuracy (14 +/- 5.3 mm). CONCLUSIONS: Body surface potentials and reconstructed epicardial activation patterns during LV pacing correlate well with endocardial data acquired invasively. The exception was during pacing of the septum. Although early results are encouraging, further quantitative data are required to fully validate and apply this noninvasive tool in the clinical arena.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Estimulação Cardíaca Artificial/métodos , Diagnóstico por Computador/métodos , Diagnóstico por Imagem/métodos , Eletrocardiografia/métodos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Humanos , Masculino , Pessoa de Meia-Idade
7.
J Electrocardiol ; 39(4 Suppl): S188-92, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16950332

RESUMO

As nonpharmacologic therapies for atrial fibrillation expand, the complexity of the anatomical and electrical substrates of atrial fibrillation requires integration of multiple imaging modalities for successful treatment. Combining chamber-specific imaging and electrophysiologic data points during ablation therapy has improved pulmonary vein isolation accuracy while diminishing risk. Merging 3-dimensional computed tomography left atrial renditions, intracardiac echocardiography, and electroanatomical mapping during pulmonary vein isolation is a reality that relates the complex anatomy of the left atrium to its often variable electrical targets. Direct visualization of radiofrequency lesion formation as well as electrode-tissue contact during current delivery has been accomplished in animal models using ultrasound and infrared imaging tools. The combination of these early integrative stepping stones may lead to imaging with real-time feedback relating tissue desiccation to electrical effect and lesion transmurality. Atrial fibrillation ablation outcome will improve as the electrophysiology laboratory continues to integrate real-time 3-dimensional cardiac chamber and tissue images before, during, and after radiofrequency or cryoablation of specific electrophysiologic targets.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Diagnóstico por Imagem/métodos , Eletrocardiografia/métodos , Terapia Assistida por Computador/métodos , Humanos , Prognóstico , Integração de Sistemas , Resultado do Tratamento
8.
Am J Cardiol ; 98(5): 591-6, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16923442

RESUMO

Epicardial electrical events were reconstructed using an inverse model for left ventricular (LV) pacing and during ventricular tachycardia (VT) induced during implantation of a biventricular pacemaker and/or internal defibrillator. The electrocardiographic position of the pacing lead, determined from the region of most negative potential 30 ms after the pacing spike, was compared with the radiographic position. Activation characterized by isochronal maps was correlated with the echocardiographic/myocardial scintigraphic data. Reconstructed epicardial isopotential/isochronal maps during VT were used to determine the presence of reentry. In 7 patients during LV pacing, epicardial isopotential maps located the maximum negative potentials anterolaterally (n = 3), posterolaterally (n = 2), and posteriorly (n = 2). Isochronal maps demonstrated activation patterns including regions of delayed activation that, in 5 patients, correlated with areas of akinesia/hypokinesia or fixed defects on echocardiography/myocardial scintigraphy. The mean difference between the radiographically measured right ventricular to LV pacing lead distance and calculated electrocardiographic right ventricular to LV pacing site distance was 1.7 cm. During VT, induced in 5 patients, single-loop reentry was observed in 3 and figure-of-8 reentry in 2. Exit site and regions of fast/slow conduction and conduction block that correlated with anatomic areas of infarction defined by echocardiography/myocardial scintigraphy were demonstrated. In conclusion, epicardial maps reconstructed from the body surface map can identify LV pacing sites and demonstrate reentry during VT. The body surface map could thus identify optimal pacing sites for LV pacing and targets for VT ablation.


Assuntos
Mapeamento Potencial de Superfície Corporal , Estimulação Cardíaca Artificial/métodos , Doença das Coronárias/complicações , Taquicardia Ventricular/fisiopatologia , Disfunção Ventricular Esquerda/complicações , Idoso , Doença das Coronárias/fisiopatologia , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Taquicardia Ventricular/complicações , Taquicardia Ventricular/terapia , Disfunção Ventricular Esquerda/fisiopatologia