Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioorg Med Chem Lett ; 74: 128927, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-35944849

RESUMO

Cathepsin K (Cat K) is a cysteine protease involved in bone remodeling. In addition to its role in bone biology, Cat K is upregulated in osteoclasts, chondrocytes and synoviocytes in osteoarthritic (OA) disease states making it a potential therapeutic target for disease-modifying OA. Starting from a prior preclinical compound, MK-1256, lead optimization efforts were carried out in the search for potent Cat K inhibitors with improved selectivity profiles with an emphasis on cathepsin F. Herein, we report the SAR studies which led to the discovery of the highly selective oxazole compound 23, which was subsequently shown to inhibit cathepsin K in vivo as measured by reduced levels of urinary C-telopeptide of collagen type I in dog.


Assuntos
Osteoartrite , Animais , Osso e Ossos , Catepsina K , Catepsinas , Condrócitos , Inibidores de Cisteína Proteinase/química , Inibidores de Cisteína Proteinase/farmacologia , Inibidores de Cisteína Proteinase/uso terapêutico , Cães , Osteoartrite/tratamento farmacológico , Osteoclastos
2.
Bioanalysis ; 13(7): 575-585, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33749335

RESUMO

Aim: To quantify the free form of a protein as a target-engagement biomarker in nonhuman primate serum, a Meso Scale Discovery ligand-binding assay was developed and qualified. Results: The initial assay produced an unexpected artifact when used to measure the free target in study samples dosed with drug. By using incurred study samples dosed with high drug levels to test assay performance, we developed an alternative assay that does not suffer from drug interference. Conclusion: Our work demonstrated that an assay designed to measure free target may not necessarily deliver reliable quantitation. In our case, incurred study samples dosed with drug proved to be useful in developing an alternative free assay that does not suffer from drug interference.


Assuntos
Desenvolvimento de Medicamentos , Preparações Farmacêuticas/sangue , Animais , Biomarcadores/sangue , Ligantes
3.
Bioorg Med Chem Lett ; 26(12): 2952-2956, 2016 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-27133481

RESUMO

A series of N-heterocyclic pyridinone catechol-O-methyltransferase (COMT) inhibitors were synthesized. Physicochemical properties, including ligand lipophilic efficiency (LLE) and clogP, were used to guide compound design and attempt to improve inhibitor pharmacokinetics. Incorporation of heterocyclic central rings provided improvements in physicochemical parameters but did not significantly reduce in vitro or in vivo clearance. Nevertheless, compound 11 was identified as a potent inhibitor with sufficient in vivo exposure to significantly affect the dopamine metabolites homovanillic acid (HVA) and dihydroxyphenylacetic acid (DOPAC), and indicate central COMT inhibition.


Assuntos
Inibidores de Catecol O-Metiltransferase/farmacologia , Catecol O-Metiltransferase/metabolismo , Compostos Heterocíclicos/farmacologia , Piridonas/farmacologia , Animais , Inibidores de Catecol O-Metiltransferase/síntese química , Inibidores de Catecol O-Metiltransferase/química , Relação Dose-Resposta a Droga , Compostos Heterocíclicos/síntese química , Compostos Heterocíclicos/química , Humanos , Modelos Moleculares , Estrutura Molecular , Piridonas/síntese química , Piridonas/química , Ratos , Relação Estrutura-Atividade
4.
Cardiovasc Eng Technol ; 7(1): 7-22, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26628081

RESUMO

We present advanced particle image velocimetry (PIV) processing, post-processing, and uncertainty estimation techniques to support the validation of computational fluid dynamics analyses of medical devices. This work is an extension of a previous FDA-sponsored multi-laboratory study, which used a medical device mimicking geometry referred to as the FDA benchmark nozzle model. Experimental measurements were performed using time-resolved PIV at five overlapping regions of the model for Reynolds numbers in the nozzle throat of 500, 2000, 5000, and 8000. Images included a twofold increase in spatial resolution in comparison to the previous study. Data was processed using ensemble correlation, dynamic range enhancement, and phase correlations to increase signal-to-noise ratios and measurement accuracy, and to resolve flow regions with large velocity ranges and gradients, which is typical of many blood-contacting medical devices. Parameters relevant to device safety, including shear stress at the wall and in bulk flow, were computed using radial basis functions. In addition, in-field spatially resolved pressure distributions, Reynolds stresses, and energy dissipation rates were computed from PIV measurements. Velocity measurement uncertainty was estimated directly from the PIV correlation plane, and uncertainty analysis for wall shear stress at each measurement location was performed using a Monte Carlo model. Local velocity uncertainty varied greatly and depended largely on local conditions such as particle seeding, velocity gradients, and particle displacements. Uncertainty in low velocity regions in the sudden expansion section of the nozzle was greatly reduced by over an order of magnitude when dynamic range enhancement was applied. Wall shear stress uncertainty was dominated by uncertainty contributions from velocity estimations, which were shown to account for 90-99% of the total uncertainty. This study provides advancements in the PIV processing methodologies over the previous work through increased PIV image resolution, use of robust image processing algorithms for near-wall velocity measurements and wall shear stress calculations, and uncertainty analyses for both velocity and wall shear stress measurements. The velocity and shear stress analysis, with spatially distributed uncertainty estimates, highlights the challenges of flow quantification in medical devices and provides potential methods to overcome such challenges.


Assuntos
Engenharia Biomédica/métodos , Desenho Assistido por Computador , Hidrodinâmica , Processamento de Imagem Assistida por Computador/métodos , Reologia/métodos , Equipamentos e Provisões , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
5.
ACS Med Chem Lett ; 6(3): 318-23, 2015 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-25815153

RESUMO

3-Hydroxy-4-pyridinones and 5-hydroxy-4-pyrimidinones were identified as inhibitors of catechol-O-methyltransferase (COMT) in a high-throughput screen. These heterocyclic catechol mimics exhibit potent inhibition of the enzyme and an improved toxicity profile versus the marketed nitrocatechol inhibitors tolcapone and entacapone. Optimization of the series was aided by X-ray cocrystal structures of the novel inhibitors in complex with COMT and cofactors SAM and Mg(2+). The crystal structures suggest a mechanism of inhibition for these heterocyclic inhibitors distinct from previously disclosed COMT inhibitors.

6.
J Appl Clin Med Phys ; 15(5): 4838, 2014 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-25207567

RESUMO

A dose calculation verification system (VS) was acquired and commissioned as a second check on the treatment planning system (TPS). This system reads DICOM CT datasets, RT plans, RT structures, and RT dose from the TPS and automatically, using its own collapsed cone superposition/convolution algorithm, computes dose on the same CT dataset. The system was commissioned by extracting basic beam parameters for simple field geometries and dose verification for complex treatments. Percent depth doses (PDD) and profiles were extracted for field sizes using jaw settings 3 × 3 cm2 - 40 × 40 cm2 and compared to measured data, as well as our TPS model. Smaller fields of 1 × 1 cm2 and 2 × 2 cm2 generated using the multileaf collimator (MLC) were analyzed in the same fashion as the open fields. In addition, 40 patient plans consisting of both IMRT and VMAT were computed and the following comparisons were made: 1) TPS to the VS, 2) VS to measured data, and 3) TPS to measured data where measured data is both ion chamber (IC) and film measurements. Our results indicated for all field sizes using jaw settings PDD errors for the VS on average were less than 0.87%, 1.38%, and 1.07% for 6x, 15x, and 18x, respectively, relative to measured data. PDD errors for MLC field sizes were less than 2.28%, 1.02%, and 2.23% for 6x, 15x, and 18x, respectively. The infield profile analysis yielded results less than 0.58% for 6x, 0.61% for 15x, and 0.77% for 18x for the VS relative to measured data. Analysis of the penumbra region yields results ranging from 66.5% points, meeting the DTA criteria to 100% of the points for smaller field sizes for all energies. Analysis of profile data for field sizes generated using the MLC saw agreement with infield DTA analysis ranging from 68.8%-100% points passing the 1.5%/1.5 mm criteria. Results from the dose verification for IMRT and VMAT beams indicated that, on average, the ratio of TPS to IC and VS to IC measurements was 100.5 ± 1.9% and 100.4 ± 1.3%, respectively, while our TPS to VS was 100.1 ± 1.0%. When comparing the TPS and VS to film measurements, the average percentage pixels passing a 3%/3mm criteria based gamma analysis were 96.6 ± 4.2% and 97 ± 5.6%, respectively. When the VS was compared to the TPS, on average 98.1 ± 5.3% of pixels passed the gamma analysis. Based upon these preliminary results, the VS system should be able to calculate dose adequately as a verification tool of our TPS.


Assuntos
Modelos Biológicos , Modelos Estatísticos , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/normas , Validação de Programas de Computador , Software , Simulação por Computador , Humanos , Garantia da Qualidade dos Cuidados de Saúde/métodos , Dosagem Radioterapêutica
7.
Med Devices (Auckl) ; 6: 49-57, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23690701

RESUMO

The purpose of this study was first to evaluate the clot capture efficiency and capture location of six currently-marketed vena cava filters in a physiological venous flow loop, using synthetic polyacrylamide hydrogel clots, which were intended to simulate actual blood clots. After observing a measured anomaly for one of the test filters, we redirected the focus of the study to identify the cause of poor clot capture performance for large synthetic hydrogel clots. We hypothesized that the uncharacteristic low clot capture efficiency observed when testing the outlying filter can be attributed to the inadvertent use of dense, stiff synthetic hydrogel clots, and not as a result of the filter design or filter orientation. To study this issue, sheep blood clots and polyacrylamide (PA) synthetic clots were injected into a mock venous flow loop containing a clinical inferior vena cava (IVC) filter, and their captures were observed. Testing was performed with clots of various diameters (3.2, 4.8, and 6.4 mm), length-to-diameter ratios (1:1, 3:1, 10:1), and stiffness. By adjusting the chemical formulation, PA clots were fabricated to be soft, moderately stiff, or stiff with elastic moduli of 805 ± 2, 1696 ± 10 and 3295 ± 37 Pa, respectively. In comparison, the elastic moduli for freshly prepared sheep blood clots were 1690 ± 360 Pa. The outlying filter had a design that was characterized by peripheral gaps (up to 14 mm) between its wire struts. While a low clot capture rate was observed using large, stiff synthetic clots, the filter effectively captured similarly sized sheep blood clots and soft PA clots. Because the stiffer synthetic clots remained straight when approaching the filter in the IVC model flow loop, they were more likely to pass between the peripheral filter struts, while the softer, physiological clots tended to fold and were captured by the filter. These experiments demonstrated that if synthetic clots are used as a surrogate for animal or human blood clots for in vitro evaluation of vena cava filters, the material properties (eg, elastic modulus) and dynamic behavior of the surrogate should first be assessed to ensure that they accurately mimic an actual blood clot within the body.

8.
ACS Chem Neurosci ; 3(2): 129-40, 2012 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-22860182

RESUMO

Reduced dopamine neurotransmission in the prefrontal cortex has been implicated as causal for the negative symptoms and cognitive deficit associated with schizophrenia; thus, a compound which selectively enhances dopamine neurotransmission in the prefrontal cortex may have therapeutic potential. Inhibition of catechol-O-methyltransferase (COMT, EC 2.1.1.6) offers a unique advantage, since this enzyme is the primary mechanism for the elimination of dopamine in cortical areas. Since membrane bound COMT (MB-COMT) is the predominant isoform in human brain, a high throughput screen (HTS) to identify novel MB-COMT specific inhibitors was completed. Subsequent optimization led to the identification of novel, non-nitrocatechol COMT inhibitors, some of which interact specifically with MB-COMT. Compounds were characterized for in vitro efficacy versus human and rat MB and soluble (S)-COMT. Select compounds were administered to male Wistar rats, and ex vivo COMT activity, compound levels in plasma and cerebrospinal fluid (CSF), and CSF dopamine metabolite levels were determined as measures of preclinical efficacy. Finally, novel non-nitrocatechol COMT inhibitors displayed less potent uncoupling of the mitochondrial membrane potential (MMP) compared to tolcapone as well as nonhepatotoxic entacapone, thus mitigating the risk of hepatotoxicity.


Assuntos
Antipsicóticos/farmacocinética , Inibidores de Catecol O-Metiltransferase , Catecol O-Metiltransferase/metabolismo , Inibidores Enzimáticos/farmacologia , Animais , Antipsicóticos/síntese química , Benzofenonas/química , Benzofenonas/farmacologia , Biomarcadores , Western Blotting , Catecol O-Metiltransferase/isolamento & purificação , Membrana Celular/enzimologia , Membrana Celular/metabolismo , Dopamina/metabolismo , Inibidores Enzimáticos/química , Humanos , Isoenzimas/antagonistas & inibidores , Isoenzimas/isolamento & purificação , Isoenzimas/metabolismo , Masculino , Metaloproteinases da Matriz/metabolismo , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Nitrofenóis/química , Nitrofenóis/farmacologia , Ratos , Ratos Sprague-Dawley , Ratos Wistar , Proteínas Recombinantes/química , Esquizofrenia/tratamento farmacológico , Especificidade por Substrato , Tolcapona
9.
J Acoust Soc Am ; 131(6): 4283-91, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22712903

RESUMO

Infrared (IR) thermography is a technique that has the potential to rapidly and noninvasively determine the intensity fields of ultrasound transducers. In the work described here, IR temperature measurements were made in a tissue phantom sonicated with a high-intensity focused ultrasound (HIFU) transducer, and the intensity fields were determined using a previously published mathematical formulation relating intensity to temperature rise at a tissue/air interface. Intensity fields determined from the IR technique were compared with those derived from hydrophone measurements. Focal intensities and beam widths determined via the IR approach agreed with values derived from hydrophone measurements to within a relative difference of less than 10%, for a transducer with a gain of 30, and about 13% for a transducer with a gain of 60. At axial locations roughly 1 cm in front (pre-focal) and behind (post-focal) the focus, the agreement with hydrophones for the lower-gain transducer remained comparable to that in the focal plane. For the higher-gain transducer, the agreement with hydrophones at the pre-focal and post-focal locations was around 40%.


Assuntos
Termografia/métodos , Terapia por Ultrassom/instrumentação , Ultrassom , Raios Infravermelhos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Espectrofotometria Infravermelho , Fatores de Tempo , Transdutores
10.
Cancer Biol Ther ; 9(7): 493-503, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20139722

RESUMO

The PI3K-Akt pathway is dysregulated in the majority of solid tumors. Pharmacological inhibition of Akt is a promising strategy for treating tumors resistant to growth factor receptor antagonists due to mutations in PI3K or PTEN. We have developed allosteric, isozyme-specific inhibitors of Akt activity and activation, as well as ex vivo kinase assays to measure inhibition of individual Akt isozymes in tissues. Here we describe the relationship between PK, Akt inhibition, hyperglycemia and tumor efficacy for a selective inhibitor of Akt1 and Akt2 (AKTi). In nude mice, AKTi treatment caused transient insulin resistance and reversible, dose-dependent hyperglycemia and hyperinsulinemia. Akt1 and Akt2 phosphorylation was inhibited in mouse lung with EC50 values of 1.6 and 7 µM, respectively, and with similar potency in other tissues and xenograft tumors. Weekly subcutaneous dosing of AKTi resulted in dose-dependent inhibition of LNCaP prostate cancer xenografts, an AR-dependent tumor with PTEN deletion and constitutively activated Akt. Complete tumor growth inhibition was achieved at 200 mpk, a dose that maintained inhibition of Akt1 and Akt2 of greater than 80% and 50%, respectively, for at least 12 hours in xenograft tumor and mouse lung. Hyperglycemia could be controlled by reducing C(max), while maintaining efficacy in the LNCaP model, but not by insulin administration. AKTi treatment was well tolerated, without weight loss or gross toxicities. These studies supported the rationale for clinical development of allosteric Akt inhibitors and provide the basis for further refining of pharmacokinetic properties and dosing regimens of this class of inhibitors.


Assuntos
Glucose/metabolismo , Indazóis/farmacologia , Indóis/farmacologia , Insulina/metabolismo , Naftiridinas/farmacologia , Neoplasias da Próstata/prevenção & controle , Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Regulação Alostérica , Animais , Humanos , Hiperglicemia/tratamento farmacológico , Hiperglicemia/metabolismo , Indazóis/farmacocinética , Indóis/farmacocinética , Isoenzimas , Masculino , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Naftiridinas/farmacocinética , PTEN Fosfo-Hidrolase/metabolismo , Fosforilação/efeitos dos fármacos , Neoplasias da Próstata/tratamento farmacológico , Neoplasias da Próstata/metabolismo , Transporte Proteico , Proteínas Proto-Oncogênicas c-akt/metabolismo , Transdução de Sinais , Distribuição Tecidual , Ensaios Antitumorais Modelo de Xenoenxerto
11.
ASAIO J ; 55(5): 445-51, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19701083

RESUMO

Submission of data regarding the cavitation potential of a mechanical heart valve is recommended by the U.S. Food and Drug Administration in the device-review process. An acoustic method has long been proposed for cavitation detection. However, the question as to whether such a method can differentiate the cavitation noise from the mechanical closing sound has not been sufficiently addressed. In this study, cavitation near a Medtronic Hall tilting disc valve was investigated in a pressurized pulsatile duplicator. The purpose of pressurizing the testing chambers was to prevent cavitation under a normally cavitating loading condition to isolate the mechanical closing sound. By comparing the sound signals before and after pressurization, some noticeable differences were found between them. In the time domain, the intensity of the sound under a cavitating condition was much higher. In the frequency domain, the energy distribution of a sound signal was distinctively different depending on whether cavitation occurred or not. The valve closing sound had a large amount of energy in the low-frequency range (less than about 25 kHz). When cavitation took place, the sound energy shifted toward the high-frequency range (from 25 to 500 kHz).


Assuntos
Acústica , Ruídos Cardíacos , Próteses Valvulares Cardíacas , Microbolhas/efeitos adversos , Fluxo Pulsátil/fisiologia , Análise de Falha de Equipamento/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Teste de Materiais , Som
13.
Ann Biomed Eng ; 36(11): 1764-81, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18787955

RESUMO

Inferior vena cava (IVC) filters are used to prevent pulmonary embolism (PE) in patients with deep vein thrombosis for whom anticoagulation is contraindicated. IVC filters have been shown to be effective in trapping embolized clots and preventing PE; however, among the commercially available designs, the optimal balance of clot capture efficiency, clot dissolution, and prevention of to vena cava occlusion is unknown. Clot capture efficiency has been quantified in numerous in vitro studies, in which model clots are released into a mock circulation system, with the relative capture efficiency of various IVC filters analyzed statistically. In general, two-stage filters have been found to be more efficient than one-stage filters. However, other factors may play a role in the ultimate dissolution of clots and in the overall effect of the resulting blood flow on caval vasculature. Clot dissolution has been shown to increase with increasing wall shear stress, while low and oscillating wall shear stresses are known to have a deleterious effect on vessel walls, causing intimal hyperplasia. This paper describes the effect of IVC filters on blood flow, velocity patterns, and wall shear stress by flow visualization and computational fluid dynamics.


Assuntos
Hemodinâmica/fisiologia , Modelos Cardiovasculares , Trombose/fisiopatologia , Filtros de Veia Cava , Velocidade do Fluxo Sanguíneo/fisiologia , Humanos
14.
Bioorg Med Chem Lett ; 18(14): 4186-90, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18539456

RESUMO

This paper describes the improvement of cell potency in a class of allosteric Akt 1 and 2 inhibitors. Key discoveries include identifying the solvent exposed region of the molecule and appending basic amines to enhance the physiochemical properties of the molecules. Findings from the structure-activity relationships are discussed.


Assuntos
Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Sítio Alostérico , Química Farmacêutica/métodos , Físico-Química/métodos , Desenho de Fármacos , Humanos , Concentração Inibidora 50 , Modelos Químicos , Fosforilação , Piperazinas/química , Inibidores de Proteínas Quinases/química , Proteínas Proto-Oncogênicas c-akt/química , Solventes/química , Estereoisomerismo , Relação Estrutura-Atividade
16.
Bioorg Med Chem Lett ; 18(11): 3178-82, 2008 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-18479914

RESUMO

A series of naphthyridine and naphthyridinone allosteric dual inhibitors of Akt1 and 2 have been developed. These compounds have been optimized to have potent dual activity against the activated kinase as well as the activation of Akt in cells. One molecule in particular, compound 17, has potent inhibitory activity against Akt1 and 2 in vivo in a mouse lung and efficacy in a tumor xenograft model.


Assuntos
Antineoplásicos/síntese química , Antineoplásicos/farmacologia , Naftiridinas/síntese química , Naftiridinas/farmacologia , Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Animais , Antineoplásicos/química , Técnicas de Química Combinatória , Modelos Animais de Doenças , Desenho de Fármacos , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Camundongos , Naftiridinas/química , Proteínas Proto-Oncogênicas c-akt/metabolismo , Relação Estrutura-Atividade
17.
J Acoust Soc Am ; 123(3): 1706-19, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18345858

RESUMO

A new approach for characterizing high intensity focused ultrasound (HIFU) transducers is presented. The technique is based upon the acoustic streaming field generated by absorption of the HIFU beam in a liquid medium. The streaming field is quantified using digital particle image velocimetry, and a numerical algorithm is employed to compute the acoustic intensity field giving rise to the observed streaming field. The method as presented here is applicable to moderate intensity regimes, above the intensities which may be damaging to conventional hydrophones, but below the levels where nonlinear propagation effects are appreciable. Intensity fields and acoustic powers predicted using the streaming method were found to agree within 10% with measurements obtained using hydrophones and radiation force balances. Besides acoustic intensity fields, the streaming technique may be used to determine other important HIFU parameters, such as beam tilt angle or absorption of the propagation medium.


Assuntos
Acústica/instrumentação , Modelos Teóricos , Transdutores , Ultrassom , Absorção , Humanos
18.
Bioorg Med Chem Lett ; 18(4): 1274-9, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18249537

RESUMO

This communication reports a new synthetic route of pyridopyrimidines to facilitate their structural optimization in a library fashion and describes the development of pyridopyrimidines that have excellent enzymatic and cell potency against Akt1 and Akt2. This series also shows a high level of selectivity over other closely related kinases and significantly improved caspase-3 activity with the more optimized compounds.


Assuntos
Inibidores de Proteínas Quinases/síntese química , Inibidores de Proteínas Quinases/farmacologia , Proteínas Proto-Oncogênicas c-akt/antagonistas & inibidores , Pirimidinas/síntese química , Pirimidinas/farmacologia , Aminas/síntese química , Aminas/química , Aminas/farmacologia , Caspase 3/metabolismo , Linhagem Celular Tumoral , Relação Dose-Resposta a Droga , Humanos , Concentração Inibidora 50 , Piperidinas/síntese química , Piperidinas/química , Piperidinas/farmacologia , Inibidores de Proteínas Quinases/química , Pirimidinas/química , Relação Estrutura-Atividade , Ligante Indutor de Apoptose Relacionado a TNF/farmacologia
20.
Bioorg Med Chem Lett ; 18(6): 2211-4, 2008 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-18296048
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...