Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Refract Surg ; 39(9): 582-588, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37675912

RESUMO

PURPOSE: To evaluate visual performance, spectacle independence, and quality of vision of new intraocular lenses (IOLs) for presbyopia correction with an aspheric inverted meniscus optical design (ArtIOLs; Voptica SL) in patients undergoing bilateral cataract surgery. METHODS: In this prospective study, 60 eyes from 30 patients implanted bilaterally with Art40 and Art70 IOLs were included. These new IOLs were designed with an inverted meniscus shape to improve the peripheral performance and with aspheric surfaces to induce different amounts of negative spherical aberration in each IOL model. Distance-corrected and uncorrected through-focus visual acuities and contrast sensitivity were measured 1 to 3 months after surgery. Twenty-eight patients answered Patient Reported Spectacle Independence (PRSIQ) and Quality of Vision (QoV) questionnaires. RESULTS: Mean monocular (Art40 and Art70) and binocular (Art40/70) corrected distance visual acuities (CDVA) were zero logMAR (20/20). Binocular uncorrected distance visual acuity (UDVA) at far, intermediate (66 cm), and near (40 cm) distances was 0.00 ± 0.01, 0.01 ± 0.03, and 0.09 ± 0.09 logMAR, respectively. Spectacle independence was achieved by 24 (85.7%) patients for far and intermediate vision and 20 patients (71.4%) for near vision. The number of patients never reporting experiencing glare, halos, and starbursts was 28, 27, and 26 (100%, 96.4%, and 92.9%), respectively. CONCLUSIONS: The binocular combination of two ArtIOLs models (Art40 and Art70) significantly extended the depth of focus up to at least 40 cm. This combination resulted in a full range of vision with a high level of spectacle independence and without the compromise of halos or dysphotopsias. [J Refract Surg. 2023;39(9):582-588.].


Assuntos
Extração de Catarata , Lentes Intraoculares , Menisco , Humanos , Satisfação do Paciente , Estudos Prospectivos
2.
J Refract Surg ; 38(4): 229-234, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35412927

RESUMO

PURPOSE: To evaluate peripheral refraction and contrast detection sensitivity in pseudophakic patients implanted with a new type of inverted meniscus intraocular lens (IOL) (Art25; Voptica SL) that was designed to provide better peripheral optics. METHODS: One month after cataract surgery, in 87 eyes implanted with the Art25 IOL, peripheral contrast detection sensitivity was measured psychophysically at 40° visual angle, both horizontally and vertically, and compared with a control group of 51 eyes implanted with standard biconvex IOLs. Thirty-one eyes with the Art25 IOL and 28 eyes from the control group were randomly selected to also measure peripheral refraction using a scanning Hartmann-Shack wavefront sensor along 80° in the horizontal meridian. RESULTS: Most patients achieved emmetropia and good visual acuity, and no significant adverse events were observed after cataract surgery with Art25 IOLs. Peripheral contrast detection sensitivity was significantly better (P < .01) in the group with the Art25 IOL in both directions (7.78 ± 3.24 vs 5.74 ± 2.60 vertical, 10.98 ± 5.09 vs 7.47 ± 3.96 horizontal), which was in agreement with the optical quality improvement in the periphery due to a reduction of defocus (1.97 and 1.21 diopters [D] at 40° temporal and nasal sides) and astigmatism (1.17 and 0.37 D at 40° temporal and nasal sides) that was statistically significant (P < .01) from 20° of eccentricity. CONCLUSIONS: Patients implanted with a new inverted meniscus IOL present a reduced amount of peripheral defocus and astigmatism compared to patients implanted with standard biconvex IOLs. This improvement in optical quality leads to better contrast detection sensitivity measured at 40° of eccentricity. [J Refract Surg. 2022;38(4):229-234.].


Assuntos
Astigmatismo , Catarata , Lentes Intraoculares , Menisco , Facoemulsificação , Astigmatismo/cirurgia , Sensibilidades de Contraste , Humanos , Implante de Lente Intraocular , Pseudofacia/cirurgia , Refração Ocular , Acuidade Visual
3.
Rev. méd. Chile ; 148(11)nov. 2020.
Artigo em Espanhol | LILACS | ID: biblio-1389255

RESUMO

Background: COVID-19 is highly transmissible, thus requiring strict measures to prevent its propagation. Aim: To report a survey about self-reported adherence to recommendations aimed to reduce the transmission of COVID-19, among health care personnel. Material and Methods: A cross-sectional survey among health professionals about adherence to recommendations to prevent COVID-19 transmission was carried out in a public hospital in Chile. The survey had 11 questions and was developed using Delphi methodology, according to the recommendations of the World Health Organization and the Centers for Disease Control. Results: The survey was answered by 137 of 155 invited workers. Hand washing, use of personal protection equipment, use of the elbow or tissue to sneeze, out-of-hospital hand washing and exclusive use of the uniform in the hospital, had an adherence of over 90%. The adherence to face touching avoidance during working hours, and face mask use in the public areas, was over 50%. No statistical differences were observed between gender or professionals. Conclusions: The adherence reported by health care workers was adequate in most of the evaluated recommendations.


Assuntos
Humanos , COVID-19 , Chile , Estudos Transversais , Pessoal de Saúde , Fidelidade a Diretrizes , SARS-CoV-2
4.
J Refract Surg ; 36(4): 223-229, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32267952

RESUMO

PURPOSE: To evaluate the use of the VAO adaptive optics visual simulator (Voptica SL, Murcia, Spain) for customization of spherical aberration to increase depth of focus. METHODS: Through-focus visual acuity with both high- and low-contrast letters from +1.00 to -3.00 diopters (D) was measured in 17 dilated eyes with three different induced amounts of spherical aberration for a 4.5-mm pupil diameter: control (0 µm), -0.15 µm, and -0.30 µm. RESULTS: The defocus curves followed the same behavior with both values of contrast, but the visual acuity was 0.2 logMAR lower with low contrast. The mean values of high-contrast logMAR visual acuity at far, intermediate (67 cm), and near (40 cm) were -0.10, 0.11, and 0.37 for control, 0.04, 0.00, and 0.15 for -0.15 µm, and 0.23, 0.00, and 0.06 for -0.30 µm conditions. The 95% confidence interval ranged from ±0.14 to ±0.45 logMAR and the middle 50% of the distribution was approximately 0.2 logMAR. CONCLUSIONS: Negative values of spherical aberration extend the depth of focus in different ways depending on each patient. The VAO is a new instrument that allows the visual customization of spherical aberration to enhance depth of focus. [J Refract Surg. 2020;36(4):223-229.].


Assuntos
Aberrações de Frente de Onda da Córnea/fisiopatologia , Percepção de Profundidade/fisiologia , Óptica e Fotônica , Presbiopia/terapia , Acuidade Visual , Adulto , Aberrações de Frente de Onda da Córnea/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Presbiopia/fisiopatologia , Estudos Prospectivos , Adulto Jovem
5.
Rev Med Chil ; 148(11): 1589-1597, 2020 Nov.
Artigo em Espanhol | MEDLINE | ID: mdl-33844764

RESUMO

BACKGROUND: COVID-19 is highly transmissible, thus requiring strict measures to prevent its propagation. AIM: To report a survey about self-reported adherence to recommendations aimed to reduce the transmission of COVID-19, among health care personnel. MATERIAL AND METHODS: A cross-sectional survey among health professionals about adherence to recommendations to prevent COVID-19 transmission was carried out in a public hospital in Chile. The survey had 11 questions and was developed using Delphi methodology, according to the recommendations of the World Health Organization and the Centers for Disease Control. RESULTS: The survey was answered by 137 of 155 invited workers. Hand washing, use of personal protection equipment, use of the elbow or tissue to sneeze, out-of-hospital hand washing and exclusive use of the uniform in the hospital, had an adherence of over 90%. The adherence to face touching avoidance during working hours, and face mask use in the public areas, was over 50%. No statistical differences were observed between gender or professionals. CONCLUSIONS: The adherence reported by health care workers was adequate in most of the evaluated recommendations.


Assuntos
COVID-19 , Chile , Estudos Transversais , Fidelidade a Diretrizes , Pessoal de Saúde , Humanos , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...