1.
ASAIO J ; 60(2): 154-61, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24399064

RESUMO

Arterial blood pressure and echocardiography may provide useful physiological information regarding cardiac support in patients with continuous-flow left ventricular assist devices (cf-LVADs). We investigated the accuracy and characteristics of noninvasive blood pressure during cf-LVAD support. Noninvasive arterial pressure waveforms were recorded with Nexfin (BMEYE, Amsterdam, The Netherlands). First, these measurements were validated simultaneously with invasive arterial pressures in 29 intensive care unit patients. Next, the association between blood pressure responses and measures derived by echocardiography, including left ventricular end-diastolic dimensions (LVEDDs), left ventricular end-systolic dimensions (LVESDs), and left ventricular shortening fraction (LVSF) were determined during pump speed change procedures in 30 outpatients. Noninvasive arterial blood pressure waveforms by the Nexfin monitor slightly underestimated invasive measures during cf-LVAD support. Differences between noninvasive and invasive measures (mean ± SD) of systolic, diastolic, mean, and pulse pressures were -7.6 ± 5.8, -7.0 ± 5.2, -6.9 ± 5.1, and -0.6 ± 4.5 mm Hg, respectively (all <10%). These blood pressure responses did not correlate with LVEDD, LVESD, or LVSF, while LVSF correlated weakly with both pulse pressure (r = 0.24; p = 0.005) and (dP(art)/dt)max (r = 0.25; p = 0.004). The dicrotic notch in the pressure waveform was a better predictor of aortic valve opening (area under the curve [AUC] = 0.87) than pulse pressure (AUC = 0.64) and (dP(art)/dt)max (AUC = 0.61). Patients with partial support rather than full support at 9,000 rpm had a significant change in systolic pressure, pulse pressure, and (dP(art)/dt)max during ramp studies, while echocardiographic measures did not change. Blood pressure measurements by Nexfin were reliable and may thereby act as a compliment to the assessment of the cf-LVAD patient.


Assuntos
Determinação da Pressão Arterial/métodos , Pressão Sanguínea , Coração Auxiliar , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
2.
Artif Organs ; 37(9): 754-62, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24074245

RESUMO

Patients on continuous flow left ventricular assist devices (cf-LVADs) are able to return to an active lifestyle and perform all sorts of physical activities. This study aims to evaluate exercise hemodynamics in patients with a HeartMate II cf-LVAD (HM II). Thirty (30) patients underwent a bicycle exercise test. Along with exercise capacity, systemic cardiovascular responses and pump performance were evaluated at 6 and 12 months after HM II implantation. From rest to maximum exercise, heart rate increased from 87 ± 14 to 140 ± 32 beats/minute (bpm) (P<0.01), while systolic arterial blood pressure increased from 93 ± 12 to 116 ± 21 mm Hg (P<0.01). Total cardiac output (TCO) increased from 4.1 ± 1.1 to 8.5 ± 2.8 L/min (P<0.01) while pump flow increased less, from 5.1 ± 0.7 to 6.4 ± 0.6 L/min (P<0.01). Systemic vascular resistance (SVR) decreased from 1776 ± 750 to 1013 ± 83 dynes.s/cm(5) (P<0.001) and showed the strongest correlation with TCO (r= -0.72; P<0.01). Exercise capacity was affected by older age, while blood pressure increased significantly in men compared with women. Exercise capacity remained consistent at 6 and 12 months after HM II implantation, 51% ± 13% and 52% ± 13% of predicted VO2 max for normal subjects corrected for age and gender. In conclusion, pump flow of the HM II may contribute partially to TCO during exercise, while SVR was the strongest determinant of TCO.


Assuntos
Ventrículos do Coração/cirurgia , Coração Auxiliar , Hemodinâmica , Função Ventricular Esquerda/fisiologia , Adulto , Pressão Sanguínea , Exercício Físico , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
3.
ASAIO J ; 59(4): 420-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23820282

RESUMO

The use of long-term mechanical circulatory support (MCS) for heart failure by means of implanted continuous-flow left ventricular assist devices (cf-LVADs) will increase, either to enable recovery or to provide a destination therapy. The effectiveness and user-friendliness of MCS will depend on the development of near-physiologic control strategies for which accurate estimation of pump flow is essential. To provide means for the assessment of pump flow, this study presents pump models, estimating pump flow (Q(lvad)) from pump speed (n) and pressure difference across the LVAD (Δp(lvad)) or power uptake (P). The models are evaluated for the axial-flow LVADs HeartAssist5 (HA5) and HeartMate II (HMII), and for a centrifugal pump, the HeartWare (HW). For all three pumps, models estimating Q(lvad) from Δp(lvad) only is capable of describing pump behavior under static conditions. For the axial pumps, flow estimation from power uptake alone was not accurate. When assuming an increase in pump flow with increasing power uptake, low pump flows are overestimated in these pumps. Only for the HW, pump flow increased linearly with power uptake, resulting in a power-based pump model that estimates static pump flow accurately. The addition of pressure head measurements improved accuracy in the axial cf-LVAD estimation models.


Assuntos
Coração Auxiliar , Modelos Cardiovasculares , Modelos Teóricos
4.
Eur J Cardiothorac Surg ; 44(3): e233-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23868955

RESUMO

OBJECTIVES: We evaluated our single-centre clinical experience with the HeartMate II (HM II) left ventricular assist device (LVAD) as a bridge to transplantation (BTT) in end-stage heart failure (HF) patients. METHODS: Survival rates, echocardiographic parameters, laboratory values and adverse events of 85 consecutive patients supported with a HM II were evaluated. RESULTS: Overall, mean age was 45 ± 13 years, 62 (73%) were male and non-ischaemic dilatated cardiomyopathy was present in 60 (71%) patients. The median duration of mechanical support was 387 days (IQR 150-600), with a range of 1-1835 days. The 6-month, 1-, 2-, 3- and 4-year survival rates during HM II LVAD support were 85, 81, 76, 76 and 68%, respectively. Echocardiographic parameters demonstrated effective left ventricular unloading, while laboratory results reflected adequate organ perfusion. However, HM II support was associated with adverse events, such as infections in 42 patients (49%; 0.67 events/patient-year), cardiac arrhythmia in 44 (52%; 0.86 events/patient-year), bleeding complications in 32 (38%; 0.43 events/patient-year) and neurological dysfunction in 17 (20%; 0.19 events/patient-year). CONCLUSIONS: In view of the increasing shortage of donor hearts, HM II LVAD support may be considered a life-saving treatment in end-stage HF patients, with good survival. However, it is still associated with some serious adverse events, of which neurological complications are the most critical.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/estatística & dados numéricos , Adolescente , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
5.
ASAIO J ; 53(2): 213-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17413563

RESUMO

We determined the difference between HeartMate (HM) VE auto mode, average filling 76 mL, and HM XVE Opti-Fill, average filling 79 mL, regarding blood chamber and inflow valve peak pressure pulses (BCPP and IVPP). The relation between stroke volume (SV) and peak pressures was investigated by using a circulatory mock loop. At high SVs, 79 to 83 mL, BCPP and IVPP never exceeded 400 mm Hg. For lower SVs, down to 50 mL, the peak pressures increased to 788 mm Hg for BCPP and 416 mm Hg for IVPP. Distribution of SV was measured in 2 VE and 6 XVE patients during rest and activities of daily living (ADL). For clinical comparison, percentages of SV >78 mL were determined. At rest, 2190 (VE) and 5772 (XVE) pump beats were registered and 4511 (VE) and 8713 (XVE) during ADL. Percentages of "SV >78 mL" at rest, respectively, were 42.5 +/- 3.5 and 78.2 +/- 4.7 (p < 0.01) and during ADL, respectively, 48.7 +/- 7.4 and 73.5 +/- 5.3 (p < 0.01). The Opti-Fill software shows a significant increase in percentage SV >78 mL and makes an important contribution to reducing the incidence of high peak pressures in the clinical setting.


Assuntos
Atividades Cotidianas , Pressão Sanguínea/fisiologia , Transplante de Coração , Coração Auxiliar , Volume Sistólico/fisiologia , Adulto , Desenho de Equipamento , Exercício Físico , Teste de Esforço , Feminino , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade