1.
Rev. esp. cardiol. (Ed. impr.) ; 70(12): 1059-1066, dic. 2017. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-169304

RESUMO

Introducción y objetivos: Los nuevos stents farmacoactivos (SFA), diseñados para solventar las limitaciones de los existentes, han de someterse inicialmente al análisis preclínico. El objetivo es analizar la eficacia y la seguridad de nuevos SFA con polímero biodegradable en comparación con stents convencionales (SC) y SFA comercializados en el modelo de arteria coronaria sana porcina. Métodos: Se implantaron aleatoriamente 101 stents (SC y stents liberadores de sirolimus con polímero biodegradable: 3 formulaciones test [BD1, BD2 y BD3], Orsiro, Biomime y Biomatrix) en las arterias coronarias de 34 cerdos domésticos. Se completó estudio angiográfico e histomorfométrico al mes (n = 83) y a los 3 meses (n = 18). Resultados: Los stents se implantaron en proporción stent/arteria de 1,31 ± 0,21, sin diferencias entre grupos. Al mes, los nuevos stents (BD1, BD2 y BD3) mostraron menos pérdida tardía y reestenosis angiográfica, así como menor área neointimal y reestenosis histológica (p < 0,0005) que los SC. No se observaron diferencias significativas entre los nuevos stents y los SC en endotelización, daño vascular o inflamación; solo se encontró mayor persistencia de fibrina en los nuevos (p = 0,0006). A los 3 meses, todas estas diferencias desaparecieron, excepto una menor área neointimal con el nuevo stent BD1 (p = 0,027). No hubo diferencias en ningún parámetro al mes ni a los 3 meses entre los nuevos stents y los comercializados. Conclusiones: En este modelo preclínico, los nuevos SFA con polímero biodegradable estudiados presentan menos reestenosis que los SC, sin diferencias significativas en seguridad y eficacia respecto a SFA comercializados (AU)


Introduction and objectives New drug-eluting stents (DES) designed to overcome the limitations of existing devices should initially be tested in preclinical studies. Our objective was to analyze the safety and efficacy of new biodegradable polymer-based DES compared with bare-metal stents (BMS) and commercially available DES in a model of normal porcine coronary arteries. Methods: We randomly implanted 101 stents (BMS and biodegradable polymer-based sirolimus-eluting stents: 3 test stent iterations [BD1, BD2, and BD3], Orsiro, Biomime and Biomatrix) in the coronary arteries of 34 domestic pigs. Angiographic and histomorphometric studies were conducted 1 month (n = 83) and 3 months (n = 18) later. Results: The stents were implanted at a stent/artery ratio of 1.31 ± 0.21, with no significant differences between groups. At 1 month, the new test stents (BD1, BD2 and BD3) showed less late loss and angiographic restenosis, as well as lower histologic restenosis and neointimal area (P < .0005), than the BMS. There were no differences in endothelialization, vascular injury, or inflammation between the new test stents and BMS, although the new stents showed higher fibrin deposition (P = .0006). At 3 months, all these differences disappeared, except for a lower neointimal area with the new BD1 stent (P = .027). No differences at any time point were observed between the new test stents and commercially available controls. Conclusions: In this preclinical model, the new biodegradable polymer-based DES studied showed less restenosis than BMS and no significant differences in safety or efficacy vs commercially available DES (AU)


Assuntos
Animais , Stents Farmacológicos , Stents Farmacológicos/veterinária , Sirolimo/uso terapêutico , Implantes Absorvíveis , Implantes Absorvíveis/veterinária , Modelos Animais , Resultado do Tratamento , Suínos , Reestenose Coronária/terapia , Reestenose Coronária/veterinária
2.
Rev Esp Cardiol (Engl Ed) ; 70(12): 1059-1066, 2017 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28647315

RESUMO

INTRODUCTION AND OBJECTIVES: New drug-eluting stents (DES) designed to overcome the limitations of existing devices should initially be tested in preclinical studies. Our objective was to analyze the safety and efficacy of new biodegradable polymer-based DES compared with bare-metal stents (BMS) and commercially available DES in a model of normal porcine coronary arteries. METHODS: We randomly implanted 101 stents (BMS and biodegradable polymer-based sirolimus-eluting stents: 3 test stent iterations [BD1, BD2, and BD3], Orsiro, Biomime and Biomatrix) in the coronary arteries of 34 domestic pigs. Angiographic and histomorphometric studies were conducted 1 month (n = 83) and 3 months (n = 18) later. RESULTS: The stents were implanted at a stent/artery ratio of 1.31 ± 0.21, with no significant differences between groups. At 1 month, the new test stents (BD1, BD2 and BD3) showed less late loss and angiographic restenosis, as well as lower histologic restenosis and neointimal area (P < .0005), than the BMS. There were no differences in endothelialization, vascular injury, or inflammation between the new test stents and BMS, although the new stents showed higher fibrin deposition (P = .0006). At 3 months, all these differences disappeared, except for a lower neointimal area with the new BD1 stent (P = .027). No differences at any time point were observed between the new test stents and commercially available controls. CONCLUSIONS: In this preclinical model, the new biodegradable polymer-based DES studied showed less restenosis than BMS and no significant differences in safety or efficacy vs commercially available DES.


Assuntos
Implantes Absorvíveis , Reestenose Coronária/epidemiologia , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima/epidemiologia , Polímeros , Animais , Antibióticos Antineoplásicos/administração & dosagem , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Vasos Coronários/diagnóstico por imagem , Metais , Neointima/patologia , Desenho de Prótese , Distribuição Aleatória , Sirolimo/administração & dosagem , Stents , Sus scrofa , Suínos , Resultado do Tratamento
3.
Vet J ; 176(2): 221-6, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-17466545

RESUMO

This article describes the treatment of single congenital portosystemic shunts (CPSs) (intrahepatic and extrahepatic) using an interventional radiology technique involving embolisation of anomalous vessels with percutaneous coils. Briefly, a multipurpose catheter was introduced into the caudal vena cava and then into the portosystemic shunt. An autoexpandable stent was placed in the caudal vena cava, next to the shunt, in order to avoid coil migrations, and a cobra-like vascular catheter was used to pass through the stent and to place the coils in the shunt. This technique was used for treatment of CPS in six dogs. The results indicate that percutaneous embolisation of a CPS using coils, a less invasive technique than the traditional surgical technique, may result in complete closure of the anomalous vessel without development of portal hypertension.


Assuntos
Doenças do Cão/congênito , Doenças do Cão/cirurgia , Embolização Terapêutica/veterinária , Hepatopatias/veterinária , Sistema Porta/anormalidades , Animais , Doenças do Cão/diagnóstico por imagem , Cães , Embolização Terapêutica/métodos , Feminino , Veias Hepáticas/anormalidades , Veias Hepáticas/diagnóstico por imagem , Hepatopatias/congênito , Hepatopatias/diagnóstico por imagem , Hepatopatias/cirurgia , Masculino , Sistema Porta/diagnóstico por imagem , Sistema Porta/cirurgia , Veia Porta/anormalidades , Veia Porta/diagnóstico por imagem , Radiografia