Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Polymers (Basel) ; 16(8)2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38674981

RESUMO

Polymeric blends are employed in the production of filaments for additive manufacturing to balance mechanical and processability properties. The mechanical and thermal properties of polymeric filaments made of poly (lactic acid) (PLA), polyhydroxyalkanoates (PHA), and its blend (PLA-PHA) are investigated herein and correlated to their measured structural and physicochemical properties. PLA exhibits the highest stiffness and tensile strength, but lower toughness. The mechanical properties of the PLA-PHA blend were similar to those of PLA, but with a significantly higher toughness. Despite the lower mechanical properties of neat PHA, incorporating a small amount (12 wt.%) of PHA into PLA significantly enhances toughness (approximately 50%) compared to pure PLA. The synergistic effect is attributed to the spherulitic morphology of blended PHA in PLA, promoting interactions between the amorphous regions of both polymers. Thermal stability is notably improved in the PLA-PHA blend, as determined by thermogravimetric analysis. The blend also exhibits lower cold crystallization and glass transition temperatures as compared to PLA, which is beneficial for additive manufacturing. Following additive manufacturing, X-ray photoelectron spectroscopic showed that the three filaments present an increase in C-C and C=O bonds associated with the loss of C-O bonds. The thermal process induces a slight increase in crystallinity in PHA due to chain reorganization. The study provides insights into the thermal and structural changes occurring during the melting process of additive manufacturing.

2.
Immunohematology ; 38(3): 96-99, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36190197

RESUMO

Alloimmunization to K11 is an extremely rare event. However, given the potential clinical significance of K11 alloantibodies, allocating antigen-negative red blood cell (RBC) units is a clinical necessity. In brief, we report a 39-year-old woman with multiple comorbidities including a right lower-extremity, below-the-knee amputation, who developed aggressive osteomyelitis associated with continuous bloody oozing, leading to anemia. To address these issues, the patient required extremity amputation. Surgery required addressing the concomitant critical anemia (hemoglobin <5 g/dL). However, with anti-K11 (in addition to anti-Jka) identified, no compatible units were immediately on hand and transfusing crossmatch-incompatible, antigen-positive units was deemed too high a risk. After a national search by the American Rare Donor Program (ARDP) was unsuccessful, the ARDP identified 2 irradiated, group O, K0 (Kellnull), Jk(a-) RBC units in Japan that were predicted to be crossmatch-compatible with the patient's plasma. The units were successfully procured and infused, without evidence of adverse reactions, and the patient was able to safely undergo amputation to save her life. This case report reviews the complexities of anti-K11 detection and confirmation, as well as the processes by which K11- RBC units may be procured, which could help others in the global transfusion community should they be faced with similar challenging cases.


Assuntos
Incompatibilidade de Grupos Sanguíneos , Isoanticorpos , Adulto , Eritrócitos , Feminino , Hemoglobinas , Humanos , Japão
3.
J Mater Sci Mater Med ; 31(8): 61, 2020 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-32696259

RESUMO

In this work, pH-sensitive hydrogel nanoparticles based on N-isopropyl acrylamide (NIPAM) and methacrylic acid (MAA) at various molar ratios, were synthesized and characterized in terms of physicochemical and biological properties. FTIR and 1HNMR spectra confirmed the successful synthesis of the copolymer that formed nanoparticles. AFM images and FE-SEM micrographs showed that nanoparticles were spherical, but their round-shape was slightly compromised with MAA content; besides, the size of particles tends to decrease as MAA content increased. The hydrogels nanoparticles also exhibited an interesting pH-sensitivity, displaying changes in its particle size when changes in pH media occurred. Biological characterization results indicate that all the synthesized particles are non-cytotoxic to endothelial cells and hemocompatible, although an increase of MAA content leads to a slight increase in the hemolysis percentage. Therefore, the pH-sensitivity hydrogels may serve as a versatile platform as self-regulated drug delivery systems in response to environmental pH changes.


Assuntos
Acrilamidas/síntese química , Hidrogéis/síntese química , Ácidos Polimetacrílicos/síntese química , Acrilamidas/química , Acrilamidas/farmacologia , Animais , Células Sanguíneas/efeitos dos fármacos , Células Sanguíneas/fisiologia , Bovinos , Células Cultivadas , Liofilização , Hemólise/efeitos dos fármacos , Humanos , Hidrogéis/química , Hidrogéis/farmacologia , Concentração de Íons de Hidrogênio , Teste de Materiais , Metacrilatos/síntese química , Metacrilatos/química , Nanopartículas/química , Tamanho da Partícula , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/farmacologia , Testes de Toxicidade
4.
Polymers (Basel) ; 12(3)2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32155803

RESUMO

Bis-GMA/TTEGDMA-based resin composites were prepared with two different types of nanoclays: an organically modified laminar clay (Cloisite® 30B, montmorillonite, MMT) and a microfibrous clay (palygorskite, PLG). Their physicochemical and mechanical properties were then determined. Both MMT and PLG nanoclays were added into monomer mixture (1:1 ratio) at different loading levels (0, 2, 4, 6, 8 and 10 wt.%), and the resulting composites were characterized by scanning electron microscopy (SEM), thermogravimetric analysis (TGA), dynamic mechanical analysis (DMA) and mechanical testing (bending and compressive properties). Thermal properties, depth of cure and water absorption were not greatly affected by the type of nanoclay, while the mechanical properties of dental resin composites depended on both the variety and concentration of nanoclay. In this regard, composites containing MMT displayed higher mechanical strength (both flexural and compression) than those resins prepared with PLG due to a poor nanoclay dispersion as revealed by SEM. Solubility of the composites was dependent not only on nanoclay-type but also the mineral concentration. Dental composites fulfilled the minimum depth cure and solubility criteria set by the ISO 4049 standard. In contrast, the minimum bending strength (50 MPa) established by the international standard was only satisfied by the dental resins containing MMT. Based on these results, composites containing either MMT or PLG (at low filler contents) are potentially suitable for use in dental restorative resins, although those prepared with MMT displayed better results.

5.
Mater Sci Eng C Mater Biol Appl ; 102: 887-895, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31147060

RESUMO

Segmented polyurethanes based on polycaprolactone, 4,4 (metylene-bis-cyclohexyl) isocyanate, and l-lysine were synthesized, manufactured as small vascular grafts and characterized according to ISO 7198 standard for cardiovascular implants-tubular vascular prosthesis. In terms of mechanical properties, the newly synthesized polyurethane films exhibited lower secant modulus than Tecoflex™ SG 80A, a well-known medical grade polyurethane. Similarly, when tested as grafts, the l-lysine-based polyurethane exhibited lower longitudinal failure load (11.5 N vs. 116 N), lower circumferential failure load per unit length (5.67 N/mm vs. 14.0 N/mm) and lower suture forces for both nylon (13.3 N vs. 24.0 N) and silk (14.0 N vs. 19.3 N) when compared to Tecoflex™ SG 80A grafts. l-Lysine-based graft exhibited a burst strength of 3620 mmHg (482.6 kPa) and a compliance of 0.16%/mmHg. The cell adhesion was demonstrated with NIH/3T3 fibroblasts where cell adhesion was observed on both films and grafts, while cell alignment was observed only on the grafts. The mechanical properties of this polyurethane and the possibility of strain-induced PCL crystals as the switching phase for shape memory materials, allowed a strain recovery ratio and a strain fixity ratio with values higher than 95% and 90%, respectively, with a repeatability of the shape-memory properties up to 4 thermo-mechanical cycles. Overall, the properties of lysine-based polyurethanes are suitable for large diameter vascular grafts where cell alignment can be controlled by their shape memory potential.


Assuntos
Prótese Vascular , Lisina/farmacologia , Teste de Materiais , Fenômenos Mecânicos , Poliuretanos/farmacologia , Animais , Adesão Celular/efeitos dos fármacos , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Camundongos , Células NIH 3T3 , Estresse Mecânico , Resistência à Tração
6.
Space Sci Rev ; 215(1): 9, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30880847

RESUMO

With the advent of the Heliophysics/Geospace System Observatory (H/GSO), a complement of multi-spacecraft missions and ground-based observatories to study the space environment, data retrieval, analysis, and visualization of space physics data can be daunting. The Space Physics Environment Data Analysis System (SPEDAS), a grass-roots software development platform (www.spedas.org), is now officially supported by NASA Heliophysics as part of its data environment infrastructure. It serves more than a dozen space missions and ground observatories and can integrate the full complement of past and upcoming space physics missions with minimal resources, following clear, simple, and well-proven guidelines. Free, modular and configurable to the needs of individual missions, it works in both command-line (ideal for experienced users) and Graphical User Interface (GUI) mode (reducing the learning curve for first-time users). Both options have "crib-sheets," user-command sequences in ASCII format that can facilitate record-and-repeat actions, especially for complex operations and plotting. Crib-sheets enhance scientific interactions, as users can move rapidly and accurately from exchanges of technical information on data processing to efficient discussions regarding data interpretation and science. SPEDAS can readily query and ingest all International Solar Terrestrial Physics (ISTP)-compatible products from the Space Physics Data Facility (SPDF), enabling access to a vast collection of historic and current mission data. The planned incorporation of Heliophysics Application Programmer's Interface (HAPI) standards will facilitate data ingestion from distributed datasets that adhere to these standards. Although SPEDAS is currently Interactive Data Language (IDL)-based (and interfaces to Java-based tools such as Autoplot), efforts are under-way to expand it further to work with python (first as an interface tool and potentially even receiving an under-the-hood replacement). We review the SPEDAS development history, goals, and current implementation. We explain its "modes of use" with examples geared for users and outline its technical implementation and requirements with software developers in mind. We also describe SPEDAS personnel and software management, interfaces with other organizations, resources and support structure available to the community, and future development plans. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11214-018-0576-4) contains supplementary material, which is available to authorized users.

7.
Rev Sci Instrum ; 90(1): 014301, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30709208

RESUMO

The design and analysis of a device to measure the burst strength (strength under a state of pure radial internal pressure) and compliance of vascular grafts and flexible pressurized tubes is presented. The device comprises three main sections, viz., a clean air-dry pressure controller, a test specimen holder, and automated software for control and data collection. Air pressure is controlled by means of a valve and a dedicated mechanism allowing reaching up to 120 psi in increments of 1 psi, and recording pressure changes with 0.04 psi resolution. The circumferential strain is determined by measuring the radial displacement of the vascular graft using an optical arrangement capable of determining a maximum radial displacement of 10 mm with 0.02 mm resolution. The instrument provides a low uncertainty in compliance (±0.32%/100 mm Hg-1) and burst strength measurements. Due to its simplicity, the device can easily be reproduced in other laboratories contributing to a dedicated instrument with high resolution at low cost. The reliability of the apparatus is further confirmed by conducting finite element analysis, elasticity solutions for pressurized cylinders, and testing of small diameter vascular grafts made of a commercial aliphatic polyurethane tested under radial internal pressure.


Assuntos
Prótese Vascular , Desenho de Equipamento , Teste de Materiais/instrumentação , Pressão , Elasticidade , Análise de Elementos Finitos
8.
J Geophys Res Space Phys ; 123(10): 8422-8438, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30498648

RESUMO

Poloidal ultra-low frequency (ULF) waves between 5-10 mHz were observed by multiple satellites and three high-latitude Super Dual Auroral Radar Network (SuperDARN) radars during the recovery phase of a moderate geomagnetic storm on Jan 24-27, 2016. The long-lasting ULF waves were observed in the magnetic field and energetic particle flux perturbations during three successive passes by two Geostationary Operational Environmental Satellites (GOES) through the dayside magnetosphere, during which plasmasphere expansion and refilling were observed by two Time History of Events and Macroscale Interactions during Substorms (THEMIS) probes. The radial magnetic field oscillation was in phase (~ 180° out of phase) with the northward (southward) moving proton flux oscillation at 95 keV, consistent with high-energy drift-bounce resonance signatures of protons with second harmonic poloidal standing Alfvén waves. The longitudinal extent of the waves approached 10 hours in local time on the dayside and gradually decreased with time. High-time resolution (~ 6 s) data from three high-latitude SuperDARN radars show that the wave intensification region was localized in latitude with a radial extent of ~ 135-225 km in the subauroral ionosphere. No signature of these waves were observed by ground-based magnetometers colocated with the GOES satellites suggesting that the poloidal waves were high-m mode and thus screened by the ionosphere. During this interval one of the THEMIS probes observed a bump-on-tail ion distribution at 1-3 keV which we suggest is the source of the long-lasting second harmonic poloidal ULF waves.

9.
J Mech Behav Biomed Mater ; 79: 332-340, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29358151

RESUMO

The circumferential compliance and burst strength of vascular grafts are predicted through the conically modified von Mises and elasticity theories, providing an analytical closed form solution for both parameters. Besides the graft's radii, the model for circumferential compliance depends solely on the elastic modulus and Poisson's ratio of the polymer material, and its accuracy was verified by finite element analysis and measurements. The analytical expression of the burst strength requires accurate determination of the material's tensile and compressive yield stress, which were carefully obtained by using digital image correlation measurements in uniaxial tensile and compressive tests of the constitutive material. The average measured circumferential compliance and burst strength of an 8mm graft made of a commonly used biomaterial, Tecoflex® SG-80A, are 1.05%/100mmHg-1 and 34.1psi (1763mmHg) and the proposed analytical predictions fall within the experimental scattering. Thus, it is shown that the circumferential compliance and burst strength of vascular grafts can be analytically predicted by knowing the elastic and yield material properties accurately, without needing to actually test the graft under radial pressure. This is a major advantage which can aid in the design and tailoring of vascular grafts.


Assuntos
Prótese Vascular , Estresse Mecânico , Resistência à Tração , Módulo de Elasticidade , Elasticidade , Modelos Cardiovasculares , Pressão
10.
Space Weather ; 14(1): 22-31, 2016 01.
Artigo em Inglês | MEDLINE | ID: mdl-27642268

RESUMO

Reliable forecasts of relativistic electrons at geostationary orbit (GEO) are important for the mitigation of their hazardous effects on spacecraft at GEO. For a number of years the Space Weather Prediction Center at NOAA has provided advanced online forecasts of the fluence of electrons with energy >2 MeV at GEO using the Relativistic Electron Forecast Model (REFM). The REFM forecasts are based on real-time solar wind speed observations at L1. The high reliability of this forecasting tool serves as a benchmark for the assessment of other forecasting tools. Since 2012 the Sheffield SNB3GEO model has been operating online, providing a 24 h ahead forecast of the same fluxes. In addition to solar wind speed, the SNB3GEO forecasts use solar wind density and interplanetary magnetic field Bz observations at L1.The period of joint operation of both of these forecasts has been used to compare their accuracy. Daily averaged measurements of electron fluxes by GOES 13 have been used to estimate the prediction efficiency of both forecasting tools. To assess the reliability of both models to forecast infrequent events of very high fluxes, the Heidke skill score was employed. The results obtained indicate that SNB3GEO provides a more accurate 1 day ahead forecast when compared to REFM. It is shown that the correction methodology utilized by REFM potentially can improve the SNB3GEO forecast.

11.
J Mater Sci Mater Med ; 27(2): 35, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26704552

RESUMO

Conventional approaches to bone regeneration rarely use multiwall carbon nanotubes (MWCNTs) but instead use polymeric matrices filled with hydroxyapatite, calcium phosphates and bioactive glasses. In this study, we prepared composites of MWCNTs/polycaprolactone (PCL) for bone regeneration as follows: (a) MWCNTs randomly dispersed on PCL, (b) MWCNTs aligned with an electrical field to determine if the orientation favors the growing of human dental pulp stem cells (HDPSCs), and (c) MWCNTs modified with ß-glycerol phosphate (BGP) to analyze its osteogenic potential. Raman spectroscopy confirmed the presence of MWCNTs and BGP on PCL, whereas the increase in crystallinity by the addition of MWCNTs to PCL was confirmed by X-ray diffraction and differential scanning calorimetry. A higher elastic modulus (608 ± 4.3 MPa), maximum stress (42 ± 6.1 MPa) and electrical conductivity (1.67 × 10(-7) S/m) were observed in non-aligned MWCNTs compared with the pristine PCL. Cell viability at 14 days was similar in all samples according to the live/dead assay, but the 21 day cell proliferation, measured by MTT was higher in MWCNTs aligned with BGP. Von Kossa and Alizarin red showed larger amounts of mineral deposits on MWCNTs aligned with BGP, indicating that at 21 days, this scaffold promotes osteogenic differentiation of HDPSCs.


Assuntos
Regeneração Óssea , Polpa Dentária/citologia , Nanotubos de Carbono/química , Poliésteres/química , Células-Tronco/citologia , Alicerces Teciduais/química , Adolescente , Adulto , Osso e Ossos/citologia , Osso e Ossos/fisiologia , Técnicas de Cultura de Células/instrumentação , Técnicas de Cultura de Células/métodos , Células Cultivadas , Polpa Dentária/fisiologia , Humanos , Teste de Materiais , Osteogênese/fisiologia , Células-Tronco/fisiologia , Engenharia Tecidual/instrumentação , Engenharia Tecidual/métodos , Adulto Jovem
13.
J Mech Behav Biomed Mater ; 46: 137-47, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25792411

RESUMO

In this work, the effect of the incorporation of core-shell particles on the fracture mechanisms of the acrylic bone cements by using acoustic emission (AE) technique during the quasi-static compression mechanical test was investigated. Core-shell particles were composed of a poly(butyl acrylate) (PBA) rubbery core and a methyl methacrylate/styrene copolymer (P(MMA-co-St)) outer glassy shell. Nanoparticles were prepared with different core-shell ratio (20/80, 30/70, 40/60 and 50/50) and were incorporated into the solid phase of bone cement at several percentages (5, 10 and 15 wt%). It was observed that the particles exhibited a spherical morphology averaging ca. 125 nm in diameter, and the dynamic mechanical analysis (DMA) thermograms revealed the desired structuring pattern of phases associated with core-shell structures. A fracture mechanism was proposed taking into account the detected AE signals and the scanning electron microscopy (SEM) micrographs. In this regard, core-shell nanoparticles can act as both additional nucleation sites for microcracks (and crazes) and to hinder the microcrack propagation acting as a barrier to its growth; this behavior was presented by all formulations. Cement samples containing 15 wt% of core-shell nanoparticles, either 40/60 or 50/50, were fractured at 40% deformation. This fact seems related to the coalescence of microcracks after they surround the agglomerates of core-shell nanoparticles to continue growing up. This work also demonstrated the potential of the AE technique to be used as an accurate and reliable detection tool for quasi-static compression test in acrylic bone cements.


Assuntos
Acústica , Cimentos Ósseos/química , Força Compressiva , Teste de Materiais , Nanopartículas , Polímeros/química
14.
J Mater Chem B ; 2(14): 1966-1976, 2014 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-32261633

RESUMO

The development of elastomeric, bioresorbable, and biocompatible segmented polyurethanes (SPUs) for use in tissue-engineering applications has attracted considerable interest in recent years because of the existing need for mechanically tunable scaffolds for regeneration of different tissues. In this study segmented polyurethanes were synthesized from poly(ε-caprolactone)diol, 4,4'-methylene bis(cyclohexyl isocyanate) (HMDI) using osteogenic compounds such as ascorbic acid (AA) and l-glutamine (GL) as chain extenders, which are known to play a role in osteoblast proliferation and collagen synthesis. Fourier transform infrared spectroscopy (FTIR) revealed the formation of urethane linkages at 3373, 1729, and 1522 cm-1 (N-H stretching, C[double bond, length as m-dash]O stretching and N-H bending + C-N stretching vibrations, respectively) while urea formation was confirmed by the appearance of a peak at 1632 cm-1. Differential scanning calorimetry, dynamic mechanical analysis, X-ray diffraction and mechanical testing of the polyurethanes showed that these polyurethanes were semi-crystalline polymers (Tg = -25 °C; Tm = 51.4-53.8 °C; 2θ = 21.3° and 23.4°) exhibiting elastomeric behavior (ε > 1000%) only for those prepared by HA incorporation during prepolymer formation. Dense and porous composite matrices of the segmented polyurethanes were prepared by the addition of hydroxyapatite (HA) via either mechanical mixing or in situ polymerization and supercritical fluid processing, respectively. The addition of HA by physical mixing decreased the crystallinity (from 38% to 31%) of the composites prepared with ascorbic acid as the chain extender. Both Tg of the composites and the strain were also lowered to -38 or 36 °C and 27-39% for ascorbic acid and glutamine containing polyurethanes respectively. Composites prepared with ascorbic acid as the chain extender yielded higher Young's modulus and tensile strength than composites prepared with glutamine when HA was incorporated during prepolymer formation. Composites obtained by incorporation of HA by physical mixing revealed a poor dispersion in comparison to composites obtained via HA inclusion during prepolymer formation. In contrast, good dispersion of HA and porosity were achieved at 60 °C, 400 bar and holding times between 0.5 h and 2 h with a downtime between 15 min and 60 min in the CO2 reactor. Biocompatibility studies showed that SPUs containing ascorbic acid allowed the increase of alveolar osteoblast proliferation; hence, they are potentially suitable for bone tissue regeneration.

15.
Cryo Letters ; 34(4): 360-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23995403

RESUMO

This work deals with the construction and performance of a measuring system capable of estimating temperature at sufficiently high speed (up to 1000 samples per sec). Due to its simple design and the utilization of standard materials, it could serve to recording the cooling profile of ultra-rapid procedures. An immersion device was also developed with the purpose of normalize the penetration speed of the sample in the LN2. The device allows also the comparative analysis of different cooling profiles. The system consists of an immersion device of the sample in the cooling agent, a temperature measurement system developed by Kleihans F and a laptop computer. To test the system, we recorded the cooling profiles of 10 uL of distilled water and 6 M glycerol solution, obtaining a cooling rate of 8732 C/min and 4441 C/min respectively. Also we determine a cooling rate of 204.012 C/min during the immersion of the thermocouple assembly in LN2. Although, the same device, with small technical modifications related to the handling of the sample, could be used to evaluate the recovery from LN2 temperature to room temperature (re-warming).


Assuntos
Termômetros , Temperatura Baixa , Desenho de Equipamento , Glicerol/química , Nitrogênio/química , Soluções , Fatores de Tempo , Água/química
16.
Cryo Letters ; 34(4): 432-52, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23995411

RESUMO

Isolated liver cells (primarily isolated hepatocytes) have found important applications in science and medicine over the past 40 years in a wide range of areas, including physiological studies, investigations on liver metabolism, organ preservation and drug de-toxification, experimental and clinical transplantation. An integral component of many of these works is the need to store the isolated cells, either for short or long-term periods. This review covers the biopreservation of liver cells, with a focus on the history of liver cell biopreservation, the application of hypothermia for short-term storage, standard cryopreservation methods for isolated hepatocytes, the biopreservation of other types of liver cells, and recent developments such as vitrification of hepatocytes. By understanding the basis for the different approaches, it will be possible to select the best options for liver cell biopreservation in different applications, and identify ways to improve preservation protocols for the future.


Assuntos
Criopreservação/métodos , Hepatócitos/citologia , Refrigeração/métodos , Vitrificação , Animais , Criopreservação/história , Dessecação/métodos , História do Século XX , História do Século XXI , Humanos , Refrigeração/história
17.
J Biomater Appl ; 28(1): 38-48, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23812945

RESUMO

Nanocomposites were prepared with segmented polyurethanes and Cloisite 30B by either solution mixing or in situ polymerization and characterized by Fourier transform infrared spectroscopy, differential scanning calorimetry, thermogravimetric analysis and X-ray diffraction. Cytotoxicity and genotoxicity were assessed with lymphocytes while cell viability was measured by the methyl tetrazolium assay using fibroblasts. It was found that in situ polymerization rendered exfoliated nanocomposites with higher glass transition temperature, tensile modulus and thermal stability compared to nanocomposites obtained by solution mixing. The mitotic index of lymphocytes was significantly reduced at high clay concentrations (6 wt% and 10 wt%), while fibroblast viability improved in the presence of extract obtained after days 2 and 7.


Assuntos
Bentonita/química , Materiais Biocompatíveis/química , Nanocompostos/química , Poliuretanos/química , Bentonita/toxicidade , Materiais Biocompatíveis/toxicidade , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Fibroblastos/citologia , Fibroblastos/efeitos dos fármacos , Humanos , Linfócitos/citologia , Linfócitos/efeitos dos fármacos , Teste de Materiais , Microscopia Eletrônica de Varredura , Mitose/efeitos dos fármacos , Nanocompostos/toxicidade , Nanocompostos/ultraestrutura , Nanotecnologia , Poliuretanos/toxicidade , Espectroscopia de Infravermelho com Transformada de Fourier , Resistência à Tração , Termodinâmica , Difração de Raios X
18.
Mater Sci Eng C Mater Biol Appl ; 33(3): 1737-43, 2013 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-23827631

RESUMO

Core-shell nanoparticles consisting of polybutyl acrylate (PBA) rubbery core and a polymethyl methacrylate (PMMA) shell, with different core-shell ratios, were synthesized in order to enhance the fracture toughness of the acrylic bone cements prepared with them. It was observed by TEM and SEM that the core-shell nanoparticles exhibited a spherical morphology with ca. 120 nm in diameter and that both modulus and tensile strength decreased by increasing the PBA content; the desired structuring pattern in the synthesized particles was confirmed by DMA. Also, experimental bone cements were prepared with variable amounts (0, 5, 10 and 20 wt.%) of nanoparticles with a core-shell ratio of 30/70 in order to study the influence of these nanostructured particles on the physicochemical, mechanical and fracture properties of bone cements. It was found that the addition of nanostructured particles to bone cements caused a significant reduction in the peak temperature and setting time while the glass transition temperature (Tg) of cements increased with increasing particles content. On the other hand, modulus and strength of bone cements decreased when particles were incorporated but fracture toughness was increased.


Assuntos
Fenômenos Mecânicos , Nanopartículas/química , Polimetil Metacrilato/química , Polimetil Metacrilato/síntese química , Força Compressiva , Módulo de Elasticidade , Emulsões/química , Látex/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Peso Molecular , Nanopartículas/ultraestrutura , Tamanho da Partícula , Polimerização , Pós , Espectroscopia de Infravermelho com Transformada de Fourier , Estresse Mecânico , Resistência à Tração
19.
J Mater Sci Mater Med ; 24(7): 1733-44, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23615787

RESUMO

Polyurethanes are very often used in the cardiovascular field due to their tunable physicochemical properties and acceptable hemocompatibility although they suffer from poor endothelialization. With this in mind, we proposed the synthesis of a family of degradable segmented poly(urea)urethanes (SPUUs) using amino acids (L-arginine, glycine and L-aspartic acid) as chain extenders. These polymers degraded slowly in PBS (pH 7.4) after 24 weeks via a gradual decrease in molecular weight. In contrast, accelerated degradation showed higher mass loss under acidic, alkaline and oxidative media. MTT tests on polyurethanes with L-arginine as chain extenders showed no adverse effect on the metabolism of human umbilical vein endothelial cells (HUVECs) indicating the leachables did not provoke any toxic responses. In addition, SPUUs containing L-arginine promoted higher levels of HUVECs adhesion, spreading and viability after 7 days compared to the commonly used Tecoflex(®) polyurethane. The biodegradability and HUVEC proliferation on L-arginine-based SPUUs suggests that they can be used in the design of vascular grafts for tissue engineering.


Assuntos
Arginina/química , Ácido Aspártico/química , Glicina/química , Teste de Materiais , Poliuretanos/química , Poliuretanos/síntese química , Implantes Absorvíveis , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Células Endoteliais da Veia Umbilical Humana/fisiologia , Humanos , Teste de Materiais/métodos , Modelos Biológicos , Polímeros/síntese química , Polímeros/química , Polímeros/farmacologia , Poliuretanos/farmacologia
20.
J Biomater Sci Polym Ed ; 24(14): 1601-17, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23544871

RESUMO

Novel biodegradable segmented polyurethanes (SPUs) were synthesized with polycaprolactone diol, 4,4'-methylen bis (cyclohexyl isocyanate) (HMDI), and either L-glutathione or its constituent amino acids (L-glutamic acid, L-cysteine and glycine) as chain extenders. Fourier transform infrared spectroscopy analysis revealed the feasibility of obtaining polyurethanes through the presence of NH (Amide II), C-N, C-O, and C=O bands and the absence of NCO band. Differential scanning calorimetry and X-ray diffraction revealed that a semicrystalline polymer (T m = 42-52 °C; 2θ = 21.3° and 23°) was obtained in all cases, while dynamic mechanical analysis (DMA) revealed an amorphous phase (T g = -30 to -36 (o)C). These properties, in addition to their high molecular weight, led to high moduli and higher extensibilities when glycine and glutamic acid were used as chain extenders. Clotting times (Lee-White test) and activated partial thromboplastin time determined on these polyurethanes were longer than with glass. In addition, all synthesized SPU exhibited platelet activation indexes below the collagen type I positive control. Human umbilical vein endothelial cells viability was higher in SPUs containing either glycine or cysteine. The obtained results indicate that SPUs that use cysteine as chain extender are promising candidates for cardiovascular applications.


Assuntos
Aminoácidos/química , Glutationa/química , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Ativação Plaquetária/efeitos dos fármacos , Poliuretanos/química , Poliuretanos/farmacologia , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Humanos , Teste de Materiais , Fenômenos Mecânicos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...