Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Waste Manag ; 125: 215-219, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33711735

RESUMO

Biological tests are widely used to assess composting process status and finished material stability. Although compost stability is known to be influenced by moisture content (MC) and storage duration, there is a lack of data supporting boundary limits for standardised testing. Using the ORG0020 dynamic respiration test we assessed the stability of materials from different commercial composting sites processing only green waste or mixed green and food waste. Samples were tested at three different MC following adjustment with the 'fist' test within the range 40-60%. The results showed manipulation of MC within this range could have significant impact on measured stability for some but not all samples. Two samples reported significantly higher activity when MC was manipulated from ~50% to ~60%. For storage duration, samples showed significant decrease in measured activity over several weeks of cold storage. However, there was no significant difference in stability for samples tested up to nine days from receipt. The results of this research will support decisions relating to the boundary limits for moisture content and storage time for the ORG0020 test. The results will also provide insight to the wider range of biological tests used to assess compost stability.


Assuntos
Compostagem , Eliminação de Resíduos , Alimentos , Respiração , Solo
2.
PLoS One ; 12(2): e0171556, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28187135

RESUMO

The WHO Consensus Document on the epidemiology of the SARS epidemic in 2003, included a report on a concentrated outbreak in one Hong Kong housing block which was considered a 'super-spreading event'. The WHO report conjectured that the sanitary plumbing system was one transmission route for the virus. Empty U-traps allowed the aerosolised virus to enter households from the sewerage system. No biological evidence was presented. This research reports evidence that pathogens can be aerosolised and transported on airstreams within sanitary plumbing systems and enter buildings via empty U-traps. A sanitary plumbing system was built, representing two floors of a building, with simulated toilet flushes on the lower floor and a sterile chamber with extractor fan on the floor above. Cultures of a model organism, Pseudomonas putida at 106-109 cfu ml-1 in 0·85% NaCl were flushed into the system in volumes of 6 to 20 litres to represent single or multiple toilet flushes. Air and surface samples were cultured on agar plates and assessed qualitatively and semi-quantitatively. Flushing from a toilet into a sanitary plumbing system generated enough turbulence to aerosolise pathogens. Typical sanitary plumbing system airflows (between 20-30 ls-1) were sufficient to carry aerosolised pathogens between different floors of a building. Empty U-traps allowed aerosolised pathogens to enter the chamber, encouraging cross-transmission. All parts of the system were found to be contaminated post-flush. Empty U-traps have been observed in many buildings and a risk assessment indicates the potential for high risk cross-transmission under defect conditions in buildings with high pathogen loading such as hospitals. Under defective conditions (which are not uncommon) aerosolised pathogens can be carried on the airflows within sanitary plumbing systems. Our findings show that greater consideration should be given to this mode of pathogen transmission.


Assuntos
Infecções Bacterianas/transmissão , Engenharia Sanitária/normas , Esgotos/microbiologia , Humanos , Pseudomonas/patogenicidade , Engenharia Sanitária/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...