Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Ann Card Anaesth ; 18(1): 83-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25566716

RESUMO

Stanford type A aortic dissections often present to the hospital requiring emergent surgical intervention. Initial diagnosis is usually made by computed tomography; however transesophageal echocardiography (TEE) can further characterize aortic dissections with specific advantages: It may be performed on an unstable patient, it can be used intra-operatively, and it has the ability to provide continuous real-time information. Three-dimensional (3D) TEE has become more accessible over recent years allowing it to serve as an additional tool in the operating room. We present a case series of three patients presenting with type A aortic dissections and the advantages of intra-operative 3D TEE to diagnose the extent of dissection in each case. Prior case reports have demonstrated the use of 3D TEE in type A aortic dissections to characterize the extent of dissection and involvement of neighboring structures. In our three cases described, 3D TEE provided additional understanding of spatial relationships between the dissection flap and neighboring structures such as the aortic valve and coronary orifices that were not fully appreciated with two-dimensional TEE, which affected surgical decisions in the operating room. This case series demonstrates the utility and benefit of real-time 3D TEE during intra-operative management of a type A aortic dissection.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Dissecção Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/métodos , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
3.
Middle East J Anaesthesiol ; 21(6): 875-7, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23634572

RESUMO

We report a case of hemodynamically significant systolic anterior motion of the mitral valve following a David procedure. Although systolic anterior motion of the mitral valve has been reported following mitral valve repair or replacement and aortic valve replacement, it has not been previously described following isolated ascending aortic surgery.


Assuntos
Aneurisma Aórtico/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Sístole , Obstrução do Fluxo Ventricular Externo/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...