Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 10(15)2021 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-34362014

RESUMO

BACKGROUND: Laguna-ONhE is an application for the colorimetric analysis of optic nerve images, which topographically assesses the cup and the presence of haemoglobin. Its latest version has been fully automated with five deep learning models. In this paper, perimetry in combination with Laguna-ONhE or Cirrus-OCT was evaluated. METHODS: The morphology and perfusion estimated by Laguna ONhE were compiled into a "Globin Distribution Function" (GDF). Visual field irregularity was measured with the usual pattern standard deviation (PSD) and the threshold coefficient of variation (TCV), which analyses its harmony without taking into account age-corrected values. In total, 477 normal eyes, 235 confirmed, and 98 suspected glaucoma cases were examined with Cirrus-OCT and different fundus cameras and perimeters. RESULTS: The best Receiver Operating Characteristic (ROC) analysis results for confirmed and suspected glaucoma were obtained with the combination of GDF and TCV (AUC: 0.995 and 0.935, respectively. Sensitivities: 94.5% and 45.9%, respectively, for 99% specificity). The best combination of OCT and perimetry was obtained with the vertical cup/disc ratio and PSD (AUC: 0.988 and 0.847, respectively. Sensitivities: 84.7% and 18.4%, respectively, for 99% specificity). CONCLUSION: Using Laguna ONhE, morphology, perfusion, and function can be mutually enhanced with the methods described for the purpose of glaucoma assessment, providing early sensitivity.

3.
Eur J Ophthalmol ; 28(5): 590-597, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29623722

RESUMO

PURPOSE: To evaluate the specificity of new perimetric indices based on harmony, alone and in combination with structural data, for glaucoma detection. METHODS: In this prospective observational cross-sectional study, one eye of 105 healthy subjects and 97 early and suspect glaucomas were sequentially included and examined with Cirrus optical coherence tomography, twice with OCULUS Smartfield perimeter (SPARK strategy) and twice with Humphrey Analyzer (24-2 SITA-Fast) at the Ophthalmology Department from the University Hospital La Candelaria. Disharmony in the visual field was evaluated including vertical threshold symmetry, threshold rank), and homogeneity (threshold standard deviation from its maximum) using the patient himself/herself as a reference. We also evaluated disharmony in combination with the mean deviation and the pattern standard deviation in a single index (mismatch) and various combinations of morphological and functional indices. Combinations used a new score based on values above certain critical cut-off levels of each index. RESULTS: For 95% specificity, the highest sensitivities were as follows: vertical cup/disc ratio: 28.9%; SPARK threshold rank: 29.9%; and SITA-Fast threshold standard deviation: 28.9%. For the combined indices and 100% specificity, they were 5 SPARK indices mismatch: 10.3%; 5 SITA-Fast indices mismatch: 11.3%; 8 optical coherence tomography indices: 21.9%; 13 SPARK and optical coherence tomography indices: 27.8%; and 13 SITA-Fast and optical coherence tomography indices: 32.0%. CONCLUSION: Disharmony combined with normative value-based indices and/or optical coherence tomography indices is useful for very specific early diagnosis of glaucoma.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Transtornos da Visão/diagnóstico , Campos Visuais/fisiologia , Estudos Transversais , Diagnóstico Precoce , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia de Coerência Óptica , Transtornos da Visão/fisiopatologia , Testes de Campo Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...