Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Gait Posture ; 31(3): 322-5, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20034797

RESUMO

In this paper we report on a novel algorithm for the real-time detection and timing of initial (IC) and final contact (FC) gait events. We process the vertical and antero-posterior accelerations registered at the lower trunk (L3 vertebra). The algorithm is based on a set of heuristic rules extracted from a set of 1719 steps. An independent experiment was conducted to compare the results of our algorithms with those obtained from a Digimax force platform. The results show small deviations from times of occurrence of events recorded from the platform (13+/-35 ms for IC and 9+/-54 ms for FC). Results for the FC timing are especially relevant in this field, as no previous work has addressed its temporal location through the processing of lower trunk accelerations. The delay in the real-time detection of the IC is 117+/-39 ms and 34+/-72 ms for the FC, improving previously reported results for real-time detection of events from lower trunk accelerations.


Assuntos
Algoritmos , Marcha/fisiologia , Tórax/fisiologia , Aceleração , Adulto , Feminino , Humanos , Masculino , Processamento de Sinais Assistido por Computador
2.
Artigo em Inglês | MEDLINE | ID: mdl-18003311

RESUMO

Walking distance estimation is an important issue in areas such as gait analysis, sport training or pedestrian localization. A natural location for portable inertial sensors for gait monitoring is to attach them to the user shoes. Step length can be computed by means of a biaxial accelerometer and a gyroscope on the sagittal plane. But estimations based on the direct signal integration are prone to error. This paper shows the results achieved by using a multisensor model approach to reduce uncertainty. Unbounded growth of error is reduced by means of sensor fusion techniques. The method has been tested, and early experimental results show that it provides an estimation of the walking distance with a standard deviation smaller than with single IMU similar systems.


Assuntos
Aceleração , Teste de Esforço/instrumentação , Pé/fisiologia , Monitorização Ambulatorial/instrumentação , Esforço Físico/fisiologia , Transdutores , Caminhada/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Monitorização Ambulatorial/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...