Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Vision Res ; 178: 79-85, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33161146

RESUMO

The pupil can be used as an objective measure for testing sensitivities across the visual field (pupil perimetry; PP). The recently developed gaze-contingent flicker PP (gcFPP) is a promising novel form of PP, with improved sensitivity due to retinotopically stable and repeated flickering stimulations, in a short time span. As a diagnostic tool gcFPP has not yet been benchmarked in healthy individuals. The main aims of the current study were to investigate whether gcFPP has the sensitivity to detect the blind spot, and upper versus lower visual field differences that were found before in previous studies. An additional aim was to test for the effects of attentional requirements and background luminance. A total of thirty individuals were tested with gcFPP across two separate experiments. The results showed that pupil oscillation amplitudes were smaller for stimuli presented inside as compared to outside the blind spot. Amplitudes also decreased as a function of eccentricity (i.e., distance to fixation) and were larger for upper as compared to lower visual fields. We measured the strongest and most sensitive pupil responses to stimuli presented on dark- and mid-gray backgrounds, and when observers covertly focused their attention to the flickering stimulus. GcFPP thus evokes pupil responses that are sensitive enough to detect local, and global differences in pupil sensitivity. The findings further encourage (1) the use of a gray background to prevent straylight without affecting gcFPPs sensitivity and (2) the use of an attention task to enhance pupil sensitivity.


Assuntos
Testes de Campo Visual , Campos Visuais , Anisotropia , Humanos , Pupila
2.
Front Neurol ; 9: 558, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30042727

RESUMO

Background: The pupillary light reflex is weaker for stimuli presented inside as compared to outside absolute scotomas. Pupillograph perimetry could thus be an objective measure of impaired visual processing. However, the diagnostic accuracy in detecting scotomas has remained unclear. We quantitatively investigated the accuracy of a novel form of pupil perimetry. Methods: The new perimetry method, termed gaze-contingent flicker pupil perimetry, consists of the repetitive on, and off flickering of a bright disk (2 hz; 320 cd/m2; 4° diameter) on a gray background (160 cd/m2) for 4 seconds per stimulus location. The disk evokes continuous pupil oscillations at the same rate as its flicker frequency, and the oscillatory power of the pupil reflects visual sensitivity. We monocularly presented the disk at a total of 80 locations in the central visual field (max. 15°). The location of the flickering disk moved along with gaze to reduce confounds of eye movements (gaze-contingent paradigm). The test lasted ~5 min per eye and was performed on 7 patients with cerebral visual impairment (CVI), 8 patients with primary open angle glaucoma (age >45), and 14 healthy, age/gender-matched controls. Results: For all patients, pupil oscillation power (FFT based response amplitude to flicker) was significantly weaker when the flickering disk was presented in the impaired as compared to the intact visual field (CVI: 12%, AUC = 0.73; glaucoma: 9%, AUC = 0.63). Differences in power values between impaired and intact visual fields of patients were larger than differences in power values at corresponding locations in the visual fields of the healthy control group (CVI: AUC = 0.95; glaucoma: AUC = 0.87). Pupil sensitivity maps highlighted large field scotomas and indicated the type of visual field defect (VFD) as initially diagnosed with standard automated perimetry (SAP) fairly accurately in CVI patients but less accurately in glaucoma patients. Conclusions: We provide the first quantitative and objective evidence of flicker pupil perimetry's potential in detecting CVI-and glaucoma-induced VFDs. Gaze-contingent flicker pupil perimetry is a useful form of objective perimetry and results suggest it can be used to assess large VFDs with young CVI patients whom are unable to perform SAP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...