1.
Environ Technol ; 35(5-8): 1046-54, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24645489

RESUMO

This study investigates the application of a hybrid system combining hollow-fibre membrane technology with the reductive abilities of magnetic nanoparticles for the remediation of toxic Cr(VI) and the azo dye, Remazol Black B. Nano-scale biogenic magnetite (Fe3O4), formed by microbial reduction of the mineral ferrihydrite, has a high reductive capacity due to the presence of Fe(II) in the mineral structure. The magnetic nanoparticles (approximately 20 nm) can be arrayed with Pd0 nanoparticles (approximately 5 nm) making a catalytically active nanomaterial. Membrane units, with and without nanoparticles, were challenged with either Cr(VI) or azo dye and some were supplemented with sodium formate, as an electron donor for contaminant reduction promoted by the Pd. The combination of Pd-magnetite with formate resulted in the most effective remediation strategy for both contaminants and the lifetime of the membrane unit was also increased, with 55% (19 days) and 70% (23 days) removal of the azo dye and Cr(VI), respectively. Low flow rates of 0.1 ml/min resulted in improved efficiencies due to increased contact time with the membrane/nanoparticle unit, with 70-75% removal of each contaminant. Chemical analyses of the nanoparticles post-exposure to Cr(VI) in the membrane modules indicated Pd to be more oxidized when Cr removal was maximized, and that the Cr was partially reduced to Cr(III) at the surface of the magnetite. These results have demonstrated that hollow-fibre membrane units can be enhanced for the removal of soluble, redox sensitive contaminants by incorporation of a layer of palladized biogenic nanoparticulate magnetite.


Assuntos
Compostos Azo/química , Cromo/química , Corantes/química , Paládio/química , Catálise , Microanálise por Sonda Eletrônica , Elétrons , Compostos Férricos/química , Óxido Ferroso-Férrico/química , Compostos Ferrosos/química , Formiatos/química , Geobacter/metabolismo , Nanopartículas/química , Nanoestruturas/química , Naftalenossulfonatos/química , Oxirredução , Oxigênio/química , Fatores de Tempo
2.
Water Res ; 46(4): 1113-20, 2012 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-22227242

RESUMO

Today's ultrafiltration processes use permeate flow reversal to remove fouling deposits on the feed side of ultrafiltration membranes. We report an as effective method: the opening and rapid closing of a valve on the permeate side of an ultrafiltration module. The sudden valve closure generates pressure fluctuations due to fluid inertia and is commonly known as "water hammer". Surface water was filtrated in hollow fiber ultrafiltration membranes with a small (5%) crossflow. Filtration experiments above sustainable flux levels (>125 l (m2h)(-1)) show that a periodic closure of a valve on the permeate side improves filtration performance as a consequence of reduced fouling. It was shown that this effect depends on flux and actuation frequency of the valve. The time period that the valve was closed proved to have no effect on filtration performance. The pressure fluctuations generated by the sudden stop in fluid motion due to the valve closure are responsible for the effect of fouling reduction. High frequency recording of the dynamic pressure evolution shows water hammer related pressure fluctuations to occur in the order of 0.1 bar. The pressure fluctuations were higher at higher fluxes (higher velocities) which is in agreement with the theory. They were also more effective at higher fluxes with respect to fouling mitigation.


Assuntos
Incrustação Biológica/prevenção & controle , Ultrafiltração/métodos , Água/química , Membranas Artificiais , Pressão , Ultrafiltração/instrumentação