1.
J Invasive Cardiol ; 32(12): E305-E312, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32961528

RESUMO

OBJECTIVES: To test whether administration of prasugrel after coronary artery bypass grafting (CABG) reduces saphenous vein graft (SVG) thrombosis. Use of aspirin after CABG improves graft patency, but administration of other antiplatelet agents has yielded equivocal results. METHODS: We performed a double-blind trial randomizing patients to prasugrel or placebo after CABG at four United States centers. Almost all patients were receiving aspirin. Follow-up angiography, optical coherence tomography (OCT), intravascular ultrasound (IVUS), and near-infrared spectroscopy (NIRS) were performed at 12 months. The primary efficacy endpoint was prevalence of OCT-detected SVG thrombus. The primary safety endpoint was incidence of Global Utilization of Streptokinase and t-PA for Occluded Coronary Arteries (GUSTO) severe bleeding. RESULTS: The study was stopped early due to slow enrollment after randomizing 84 patients. Mean age was 64 ± 6 years; 98% of the patients were men. Follow-up angiography was performed in 59 patients. IVUS was performed in 52 patients, OCT in 53 patients, and NIRS in 33 patients. Thrombus was identified by OCT in 56% vs 50% of patients in the prasugrel vs placebo groups, respectively (P=.78). Angiographic SVG failure occurred in 24% of patients in the prasugrel arm vs 40% in the placebo arm (P=.19). The 1-year incidence of major adverse cardiovascular events was 14.3% vs 2.4% in the prasugrel and placebo groups, respectively (P=.20), without significant differences in GUSTO severe bleeding (P=.32). CONCLUSION: Early SVG failure occurred in approximately one-third of patients. Prasugrel did not decrease prevalence of SVG thrombus 12 months after CABG.


Assuntos
Veia Safena , Trombose , Idoso , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Feminino , Oclusão de Enxerto Vascular/diagnóstico , Oclusão de Enxerto Vascular/epidemiologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Cloridrato de Prasugrel/efeitos adversos , Veia Safena/diagnóstico por imagem , Resultado do Tratamento , Grau de Desobstrução Vascular
2.
J Invasive Cardiol ; 30(6): 195-201, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29543185

RESUMO

BACKGROUND: The contemporary use and outcomes of excimer laser coronary atherectomy (ELCA) in percutaneous coronary intervention (PCI) are not well described. METHODS: We examined the baseline clinical and angiographic characteristics and procedural outcomes of 130 target lesions in 121 consecutive PCIs (n = 116 patients) in which ELCA was performed at three United States Department of Veterans Affairs (VA) medical centers between 2008 and 2016. RESULTS: Mean age was 68.5 ± 9 years and 97% of the patients were men. Patients had high prevalence of diabetes mellitus (63%), prior coronary artery bypass graft surgery (41%), and prior myocardial infarction (60%). The most common target vessel was the left anterior descending (32%), followed by the right coronary artery (30%), circumflex artery (20%), and saphenous vein graft (12%). The target lesions were highly complex, with moderate/severe calcification in 62% and in-stent restenosis in 37%. The most common indication for ELCA was balloon-uncrossable lesions (43.8%), followed by balloon-undilatable lesions (40.8%) and thrombotic lesions (12.3%). Use of ELCA was associated with high technical success rate (90.0%) and procedural success rate (88.8%), and low major adverse cardiac event (MACE) rate (3.45%). Mean procedure time was 120 min (interquartile range [IQR], 81-191 min), air kerma radiation dose was 2.76 Gy (IQR, 1.32-5.01 Gy), and contrast volume was 273 mL (IQR, 201-362 mL). CONCLUSION: In a contemporary multicenter United States registry, ELCA was commonly used in highly complex lesions and was associated with high technical and procedural success rates and low incidence of MACE.


Assuntos
Doença da Artéria Coronariana/cirurgia , Lasers de Excimer/uso terapêutico , Intervenção Coronária Percutânea/métodos , Idoso , Angiografia Coronária , Vasos Coronários/cirurgia , Feminino , Hospitais de Veteranos , Humanos , Lasers de Excimer/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento , Estados Unidos
3.
JACC Cardiovasc Interv ; 11(3): 225-233, 2018 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-29413236

RESUMO

OBJECTIVES: The authors performed a multicenter, randomized-controlled, clinical trial comparing upfront use of the CrossBoss catheter versus antegrade wire escalation for antegrade crossing of coronary chronic total occlusions. BACKGROUND: There is equipoise about the optimal initial strategy for crossing coronary chronic total occlusions. METHODS: The primary endpoints were the time required to cross the chronic total occlusion or abort the procedure and the frequency of procedural major adverse cardiovascular events. The secondary endpoints were technical and procedural success, total procedure time, fluoroscopy time required to cross and total fluoroscopy time, total air kerma radiation dose, total contrast volume, and equipment use. RESULTS: Between 2015 and 2017, 246 patients were randomized to the CrossBoss catheter (n = 122) or wire escalation (n = 124) at 11 U.S. centers. The baseline clinical and angiographic characteristics of the study groups were similar. Technical and procedural success were 87.8% and 84.1%, respectively, and were similar in the 2 groups. Crossing time was similar: 56 min (interquartile range: 33 to 93 min) in the CrossBoss group and 66 min (interquartile range: 36 to 105 min) in the wire escalation group (p = 0.323), as was as the incidence of procedural major adverse cardiovascular events (3.28% vs. 4.03%; p = 1.000). There were no significant differences in the secondary study endpoints. CONCLUSIONS: As compared with wire escalation, upfront use of the CrossBoss catheter for antegrade crossing of coronary chronic total occlusions was associated with similar crossing time, similar success and complication rates, and similar equipment use and cost.


Assuntos
Cateterismo Cardíaco/métodos , Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/métodos , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/economia , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/economia , Oclusão Coronária/fisiopatologia , Feminino , Custos Hospitalares , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/economia , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
4.
Catheter Cardiovasc Interv ; 91(4): 647-654, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28707381

RESUMO

OBJECTIVE: To examine the relationship between occupational exposure to ionizing radiation and the prevalence of lens changes in interventional cardiologists (ICs) and catheterization laboratory ("cath-lab") staff. BACKGROUND: Exposure to ionizing radiation is associated with the development of lens opacities. ICs and cath-lab staff can receive high doses of ionizing radiation without protection, and may thus be at risk for lens opacity formation. METHODS: We conducted a cross-sectional study at an interventional cardiology conference. Study participants completed a questionnaire pertaining to occupational exposure to radiation and potential confounders for the development of cataracts, followed by slit-lamp examination and grading of lens findings. RESULTS: A total of 117 attendees participated in the study, including 99 (85%; 49 ± 11 years-old; 82% male) with occupational exposure to ionizing radiation and 18 (15%; 39 ± 12 years-old; 61% male) unexposed controls. The prevalence of overall cortical and posterior subcapsular lens changes (including subclinical findings) was higher in exposed participants compared with controls (47 vs. 17%, P = 0.015). Occupational exposure and age over 60 were independent predictors of lens changes (odds ratio [95% CI]: 6.07 [1.38-43.45] and 7.72 [1.60-43.34], respectively). The prevalence of frank opacities was low and similar between the two groups (14 vs. 6%, P = 0.461). Most lens findings consisted of subclinical changes in the periphery of the lens without impact on visual acuity. CONCLUSIONS: Compared with unexposed controls, ICs and cath-lab staff had a higher prevalence of lens changes that may be attributable to ionizing radiation exposure. While most of these changes were subclinical, they are important due to the potential to progress to clinical symptoms, highlighting the importance of minimizing staff radiation exposure.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cardiologistas , Catarata/epidemiologia , Cristalino/efeitos da radiação , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/efeitos adversos , Lesões por Radiação/epidemiologia , Radiografia Intervencionista/efeitos adversos , Radiologistas , Adulto , Estudos de Casos e Controles , Catarata/diagnóstico , Catarata/fisiopatologia , Estudos Transversais , Feminino , Humanos , Cristalino/fisiopatologia , Masculino , Pessoa de Meia-Idade , Saúde Ocupacional , Salas Cirúrgicas , Prevalência , Doses de Radiação , Lesões por Radiação/diagnóstico , Lesões por Radiação/fisiopatologia , Medição de Risco , Fatores de Risco , Microscopia com Lâmpada de Fenda , Fatores de Tempo , Acuidade Visual/efeitos da radiação
5.
J Am Heart Assoc ; 6(12)2017 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-29223954

RESUMO

BACKGROUND: We sought to examine the efficacy and safety of 2 PCSK9 (proprotein convertase subtilisin/kexin type 9) inhibitors: alirocumab and evolocumab. METHODS AND RESULTS: We performed a systematic review and meta-analysis of randomized controlled trials comparing treatment with and without PCSK9 inhibitors; 35 randomized controlled trials comprising 45 539 patients (mean follow-up: 85.5 weeks) were included. Mean age was 61.0±2.8 years, and mean baseline low-density lipoprotein cholesterol was 106±22 mg/dL. Compared with no PCSK9 inhibitor therapy, treatment with a PCSK9 inhibitor was associated with a lower rate of myocardial infarction (2.3% versus 3.6%; odds ratio [OR]: 0.72 [95% confidence interval (CI), 0.64-0.81]; P<0.001), stroke (1.0% versus 1.4%; OR: 0.80 [95% CI, 0.67-0.96]; P=0.02), and coronary revascularization (4.2% versus 5.8%; OR: 0.78 [95% CI, 0.71-0.86]; P<0.001). Overall, no significant change was observed in all-cause mortality (OR: 0.71 [95% CI, 0.47-1.09]; P=0.12) or cardiovascular mortality (OR: 1.01 [95% CI, 0.85-1.19]; P=0.95). A significant association was observed between higher baseline low-density lipoprotein cholesterol and benefit in all-cause mortality (P=0.038). No significant change was observed in neurocognitive adverse events (OR: 1.12 [95% CI, 0.88-1.42]; P=0.37), myalgia (OR: 0.95 [95% CI, 0.75-1.20]; P=0.65), new onset or worsening of preexisting diabetes mellitus (OR: 1.05 [95% CI, 0.95-1.17]; P=0.32), and increase in levels of creatine kinase (OR: 0.84 [95% CI, 0.70-1.01]; P=0.06) or alanine or aspartate aminotransferase (OR: 0.96 [95% CI, 0.82-1.12]; P=0.61). CONCLUSIONS: Treatment with a PCSK9 inhibitor is well tolerated and improves cardiovascular outcomes. Although no overall benefit was noted in all-cause or cardiovascular mortality, such benefit may be achievable in patients with higher baseline low-density lipoprotein cholesterol.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Hipercolesterolemia/tratamento farmacológico , Inibidores de PCSK9 , Anticorpos Monoclonais Humanizados , Anticolesterolemiantes/uso terapêutico , Humanos , Hipercolesterolemia/sangue , Pró-Proteína Convertase 9/sangue , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
6.
J Invasive Cardiol ; 29(12): E167-E176, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28706125

RESUMO

OBJECTIVES: Outcomes with use of lesion-modification strategies in the drug-eluting stent era have received limited study. METHODS: We conducted a meta-analysis of 22 studies published between 2004-2016 reporting outcomes after use of rotational atherectomy, cutting-balloon, and scoring-balloon angioplasty. RESULTS: In observational trials, acute luminal gain was higher after lesion modification as compared with control (standardized mean difference, 0.23 mm; 95% confidence interval [CI], 0.01-0.44; P=.04), with no difference in acute gain in randomized studies. Compared with control, lesion modification was associated with lower restenosis in randomized trials (odds ratio [OR], 0.64; 95% CI, 0.45-0.90; P=.01). Ninety-day incidence of major adverse cardiovascular event (MACE) was higher after lesion modification in observational studies (OR, 1.39; 95% CI, 1.05-1.83; P=.02), but similar in randomized trials. Ninety-day incidence of target-lesion or target-vessel revascularization (TLR-TVR) and myocardial infarction (MI) was similar. Ninety-day incidence of death was higher after lesion modification in observational studies (OR, 1.42; 95% CI, 1.04-1.95; P=.03), but similar in randomized trials. At 1 year, the MACE rate was similar for lesion modification compared with control in observational studies, but lower after lesion modification in randomized trials (OR, 0.65; 95% CI, 0.48-0.88; P<.01). TLR-TVR was higher with lesion modification in observational studies, but lower in randomized trials (OR, 0.64; 95% CI, 0.46-0.88; P<.01). CONCLUSIONS: While observational studies suggest a higher early MACE rate and more restenosis, randomized trials show similar short-term and improved long-term outcomes with pre-stenting lesion modification compared with control.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/métodos , Humanos , Avaliação de Processos e Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos
7.
J Invasive Cardiol ; 29(9): 320-326, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28420803

RESUMO

BACKGROUND: The American College of Cardiology/American Heart Association (ACC/AHA) and the European Society of Cardiology (ESC) have developed guidelines to assist clinicians in making evidence-based decisions. This study compares the ACC/AHA and ESC guidelines for the management of patients with valvular heart disease (VHD). METHODS: The current ACC/AHA and ESC guidelines for VHD, last updated in 2014 and 2012, respectively, were compared by class of recommendation (COR), level of evidence (LOE), and content. RESULTS: The ACC/AHA and ESC VHD guidelines contain 229 and 85 recommendations, respectively. The COR distributions of the ACC/AHA and ESC VHD guidelines were 47.6% vs 44.7% class I [P=.65]; 46.3% vs 55.3% class II [P=.16]; and 6.1% vs 0.0% class III [P=.01], respectively. The LOE distributions were 3.1% vs 0.0% LOE A [P=.20]; 47.2% vs 10.6% LOE B [P<.001]; and 49.8% vs 89.4% LOE C [P<.001], respectively. The recommendation type distributions were 31.0% vs 2.4% diagnostic [P<.001]; 23.1% vs 16.5% medical therapy [P=.20]; and 45.9% vs 81.2% interventional/surgical recommendations [P<.001], respectively. The content of the guidelines was similar, with only minor differences in a few recommendations. CONCLUSIONS: The ACC/AHA VHD guidelines contain significantly more recommendations. The distribution of COR was similar, but the ACC/AHA guidelines included more LOE B recommendations and fewer LOE C recommendations, suggesting that the ACC/AHA guidelines place greater emphasis on published data than expert opinion. Overall, the ACC/AHA and ESC guidelines provide similar recommendations, suggesting consistency in practice; however, the relative paucity of LOE A recommendations highlights the need for additional research.


Assuntos
American Heart Association , Cardiologia , Gerenciamento Clínico , Doenças das Valvas Cardíacas/terapia , Guias de Prática Clínica como Assunto , Europa (Continente) , Humanos , Masculino , Estados Unidos
8.
J Invasive Cardiol ; 29(3): 83-91, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28255103

RESUMO

OBJECTIVES: Although coronary chronic total occlusions (CTOs) are treated with percutaneous coronary intervention (PCI) to improve symptoms, studies demonstrating symptom improvement have been mostly limited to questionnaire responses. The current study assessed for changes in peak oxygen uptake during cardiopulmonary exercise testing after CTO-PCI. METHODS: Patients with heart failure or angina symptoms referred for CTO-PCI were prospectively enrolled. The primary outcome of the study was improvement in peak oxygen uptake during cardiopulmonary exercise (CPX) testing 5 months after CTO-PCI. Secondary outcomes included improvement in physical capacity, angina, and self perception of health as assessed by questionnaires, and in plasma brain natriuretic peptide (BNP) levels. RESULTS: CTO-PCI was attempted in 32 men (mean age, 62 ± 6 years; CTO vessel: 47% right coronary, 44% left anterior descending). CTO-PCI was unsuccessful in 1 patient, and 3 patients had restenosis of their CTO vessel at follow-up. In the 28 patients with patent CTO vessel at follow-up, significant improvements were noted in self-reported physical capacity, angina, and several aspects of health perception. In the 25 patients who underwent baseline and follow-up CPX testing, peak oxygen uptake significantly improved from 17.7 ± 4.3 mL/kg/min to 19.1 ± 4.0 mL/kg/min (P=.02). Plasma BNP levels significantly decreased from 143 ± 138 pg/mL to 102 ± 123 pg/mL (P=.01). CONCLUSIONS: CTO-PCI in symptomatic patients was associated with improvements in cardiovascular exercise capacity, as assessed by peak oxygen uptake. These results suggest that in symptomatic patients with CTOs, PCI appears clinically beneficial.


Assuntos
Oclusão Coronária , Teste de Esforço/métodos , Consumo de Oxigênio , Intervenção Coronária Percutânea/métodos , Idoso , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Angina Pectoris/fisiopatologia , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Oclusão Coronária/fisiopatologia , Oclusão Coronária/cirurgia , Autoavaliação Diagnóstica , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente , Intervenção Coronária Percutânea/efeitos adversos , Resistência Física , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento , Estados Unidos
9.
Coron Artery Dis ; 28(4): 294-300, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28306587

RESUMO

INTRODUCTION: The American College of Cardiology (ACC), the American Heart Association (AHA), and the European Society of Cardiology (ESC) have been developing guidelines to assist clinicians in making evidence-based decisions. MATERIALS AND METHODS: The current ACC/AHA and ESC guidelines for non-ST-segment elevation acute coronary syndromes (NSTE-ACS) that were updated in 2014 and 2015, respectively, were compared to assess the number of recommendations on the basis of class of recommendation and level of evidence (LOE), the sources cited, and the content. RESULTS: The total number of recommendations in the ACC/AHA and ESC guidelines was 182 and 147, respectively. The recommendation class distribution of the ACC/AHA guidelines was 61.0% class I (compared with 61.9% in the ESC guidelines, P=0.865), 29.7% class II (compared with 32.0% in the ESC guidelines, P=0.653), and 9.3% class III (compared with 6.1% in the ESC guidelines, P=0.282). The LOE distribution among ACC/AHA guidelines was 15.9% LOE A (compared with 27.9% in the ESC guidelines, P=0.008), 50.0% LOE B (compared with 33.3% in the ESC guidelines, P=0.002), and 34.1% LOE C (compared with 38.8% in the ESC guidelines, P=0.377). The ACC/AHA guidelines cited 827 publications and the ESC guidelines cited 551 publications, 124 of which were shared by both sets of guidelines. The guidelines' approaches to NSTE-ACS were consistent, with minor differences in diagnostic and medical therapy recommendations. CONCLUSION: Overall, the ACC/AHA and ESC guidelines contain a comparable number of recommendations and provide similar guidance for the management of patients with NSTE-ACS.


Assuntos
Síndrome Coronariana Aguda/terapia , American Heart Association , Cardiologia , Gerenciamento Clínico , Eletrocardiografia , Guias de Prática Clínica como Assunto , Sociedades Médicas , Síndrome Coronariana Aguda/fisiopatologia , Europa (Continente) , Humanos , Estados Unidos
10.
Catheter Cardiovasc Interv ; 89(6): E172-E180, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27535486

RESUMO

OBJECTIVES: We sought to examine near-infrared spectroscopy (NIRS) imaging findings of aortocoronary saphenous vein grafts (SVGs). BACKGROUND: SVGs are prone to develop atherosclerosis similar to native coronary arteries. They have received little study using NIRS. METHODS: We examined the clinical characteristics and imaging findings from 43 patients who underwent NIRS imaging of 45 SVGs at our institution between 2009 and 2016. RESULTS: The mean patient age was 67 ± 7 years and 98% were men, with high prevalence of diabetes mellitus (56%), hypertension (95%), and dyslipidemia (95%). Mean SVG age was 7 ± 7 years, mean SVG lipid core burden index (LCBI) was 53 ± 60 and mean maxLCBI4 mm was 194 ± 234. Twelve SVGs (27%) had lipid core plaques (2 yellow blocks on the block chemogram), with a higher prevalence in SVGs older than 5 years (46% vs. 5%, P = 0.002). Older SVG age was associated with higher LCBI (r = 0.480, P < 0.001) and higher maxLCBI4 mm (r = 0.567, P < 0.001). On univariate analysis, greater annual total cholesterol exposure was associated with higher SVG LCBI (r = 0.30, P = 0.042) and annual LDL-cholesterol and triglyceride exposure were associated with higher SVG maxLCBI4 mm (LDL-C: r = 0.41, P = 0.020; triglycerides: r = 0.36, P = 0.043). On multivariate analysis, the only independent predictor of SVG LCBI and maxLCBI4mm was SVG age. SVG percutaneous coronary intervention was performed in 63% of the patients. An embolic protection device was used in 96% of SVG PCIs. Periprocedural myocardial infarction occurred in one patient. CONCLUSIONS: Older SVG age and greater lipid exposure are associated with higher SVG lipid burden. © 2016 Wiley Periodicals, Inc.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Lipídeos/análise , Placa Aterosclerótica , Veia Safena/cirurgia , Espectroscopia de Luz Próxima ao Infravermelho , Fatores Etários , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Sistema de Registros , Fatores de Risco , Veia Safena/diagnóstico por imagem , Veia Safena/patologia , Texas , Resultado do Tratamento
11.
Cardiovasc Revasc Med ; 18(3): 177-181, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28017258

RESUMO

BACKGROUND: Coronary lipid core plaque may be associated with the incidence of subsequent cardiovascular events. METHODS: We analyzed outcomes of 239 patients who underwent near-infrared spectroscopy (NIRS) coronary imaging between 2009-2011. Multivariable Cox regression was used to identify variables independently associated with the incidence of major adverse cardiovascular events (MACE; cardiac mortality, acute coronary syndromes (ACS), stroke, and unplanned revascularization) during follow-up. RESULTS: Mean patient age was 64±9years, 99% were men, and 50% were diabetic, presenting with stable coronary artery disease (61%) or an acute coronary syndrome (ACS, 39%). Target vessel pre-stenting median lipid core burden index (LCBI) was 88 [interquartile range, IQR 50-130]. Median LCBI in non-target vessels was 57 [IQR 26-94]. Median follow-up was 5.3years. The 5-year MACE rate was 37.5% (cardiac mortality was 15.0%). On multivariable analysis the following variables were associated with MACE: diabetes mellitus, prior percutaneous coronary intervention performed at index angiography, and non-target vessel LCBI. Non-target vessel LCBI of 77 was determined using receiver-operating characteristic curve analysis to be a threshold for prediction of MACE in our cohort. The adjusted hazard ratio (HR) for non-target vessel LCBI ≥77 was 14.05 (95% confidence interval (CI) 2.47-133.51, p=0.002). The 5-year cumulative incidence of events in the above-threshold group was 58.0% vs. 13.1% in the below-threshold group. CONCLUSION: During long-term follow-up of patients who underwent NIRS imaging, high LCBI in a non-PCI target vessel was associated with increased incidence of MACE.


Assuntos
Técnicas de Imagem Cardíaca , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica , Espectroscopia de Luz Próxima ao Infravermelho , Síndrome Coronariana Aguda/etiologia , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Revascularização Miocárdica , Valor Preditivo dos Testes , Prognóstico , Modelos de Riscos Proporcionais , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo
12.
J Invasive Cardiol ; 28(12): 485-488, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27922805

RESUMO

OBJECTIVE: To examine the presence and localization of lipid-core plaque (LCP) in coronary vessels with chronic total occlusions (CTOs) using near-infrared spectroscopy (NIRS). METHODS: NIRS imaging was performed after guidewire crossing of the occlusion in 15 patients with CTOs. LCP was defined as ≥2 adjacent 2 mm yellow blocks on the block chemogram. We also measured the maximum lipid-core burden index (LCBI) in a 4 mm length of artery (maxLCBI4mm). Large LCP was defined as maxLCBI4mm ≥500. RESULTS: Median patient age was 64 years (interquartile range [IQR], 61-67 years) and all patients were men with high prevalence of diabetes mellitus (64%) and prior coronary artery bypass graft surgery (27%). The CTO target vessel was the right coronary artery (46%), left anterior descending artery (27%), or circumflex artery (27%). Median occlusion length was 35 mm (IQR, 30-50 mm). LCP was present in 11 of 15 CTO vessels (73%) and a large LCP in 4 of 15 CTO vessels (27%). LCP was located at the proximal cap in 6 CTOs (55%), the CTO body in 6 CTOs (55%), and the distal cap in 2 CTOs (18%). The median overall LCBI and maxLCBI4mm were 145 (IQR, 79-243) and 415 (IQR, 267-505), respectively. All patients underwent successful stenting without any complications. The 12-month incidence of in-stent restenosis and target-lesion revascularization was 25%, and all patients who developed restenosis had an LCP at baseline. CONCLUSIONS: LCPs are commonly encountered in coronary CTO vessels, suggesting an active intraplaque atherosclerotic process. The impact of LCP on postintervention outcomes requires further study.


Assuntos
Ponte de Artéria Coronária/métodos , Oclusão Coronária , Vasos Coronários , Diabetes Mellitus/epidemiologia , Placa Aterosclerótica , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Idoso , Comorbidade , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Oclusão Coronária/epidemiologia , Oclusão Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Lipídeos/análise , Masculino , Pessoa de Meia-Idade , Placa Aterosclerótica/química , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Cuidados Pré-Operatórios/métodos , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
13.
J Invasive Cardiol ; 28(12): E185-E192, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27922810

RESUMO

OBJECTIVES: We examined a contemporary, unselected cohort of patients with coronary chronic total occlusions (CTOs) to determine the impact of CTO revascularization on long-term outcomes. METHODS: We retrospectively assessed the impact of CTO revascularization on clinical outcomes of consecutive patients found to have a CTO during coronary angiography performed at our institution during 2011 and 2012. The primary endpoint was the incidence of a major adverse cardiac event (MACE, defined as a composite of death, myocardial infarction, stroke, and target-vessel revascularization [TVR]). Survival analysis was performed in the overall and propensity-matched retrospective cohorts of patients stratified by prior coronary artery bypass graft (CABG) surgery. Propensity-adjusted hazard ratio (HR) and 95% confidence interval (95% CI) were calculated with Cox proportional hazards analysis. All analyses were by intention to treat. RESULTS: Of 624 patients (319 without prior CABG and 305 with prior CABG) included in the present analysis, CTO revascularization (surgical or percutaneous) was attempted in 60% and 16% of patients without and with prior CABG, respectively. During a median follow-up of 26 months (range, 18-40 months), the incidence of MACE was 20.6%. CTO revascularization (achieved or attempted) was associated with lower incidence of MACE among patients without prior CABG (propensity-adjusted HR, 0.51; 95% CI, 0.27-0.94; P=.03), but not among prior CABG patients (propensity-adjusted HR, 1.38; 95% CI, 0.64-2.96; P=.41). CONCLUSION: In a large, unselected patient population with coronary CTOs, a CTO revascularization attempt was associated with lower incidence of subsequent MACE among patients without prior CABG, but not among prior CABG patients.


Assuntos
Ponte de Artéria Coronária/efeitos adversos , Oclusão Coronária , Vasos Coronários/diagnóstico por imagem , Infarto do Miocárdio , Complicações Pós-Operatórias , Idoso , Angiografia Coronária/métodos , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/estatística & dados numéricos , Oclusão Coronária/diagnóstico , Oclusão Coronária/cirurgia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Estados Unidos/epidemiologia
15.
Artigo em Inglês | MEDLINE | ID: mdl-27307562

RESUMO

BACKGROUND: We sought to examine the efficacy and safety of chronic total occlusion percutaneous coronary intervention using the retrograde approach. METHODS AND RESULTS: We compared the outcomes of the retrograde versus antegrade-only approach to chronic total occlusion percutaneous coronary intervention among 1301 procedures performed at 11 experienced US centers between 2012 and 2015. The mean age was 65.5±10 years, and 84% of the patients were men with a high prevalence of diabetes mellitus (45%) and previous coronary artery bypass graft surgery (34%). Overall technical and procedural success rates were 90% and 89%, respectively, and in-hospital major adverse cardiovascular events occurred in 31 patients (2.4%). The retrograde approach was used in 539 cases (41%), either as the initial strategy (46%) or after a failed antegrade attempt (54%). When compared with antegrade-only cases, retrograde cases were significantly more complex, both clinically (previous coronary artery bypass graft surgery prevalence, 48% versus 24%; P<0.001) and angiographically (mean Japan-chronic total occlusion score, 3.1±1.0 versus 2.1±1.2; P<0.001) and had lower technical success (85% versus 94%; P<0.001) and higher major adverse cardiovascular events (4.3% versus 1.1%; P<0.001) rates. On multivariable analysis, the presence of suitable collaterals, no smoking, no previous coronary artery bypass graft surgery, and left anterior descending artery target vessel were independently associated with technical success using the retrograde approach. CONCLUSIONS: The retrograde approach is commonly used in contemporary chronic total occlusion percutaneous coronary intervention, especially among more challenging lesions and patients. Although associated with lower success and higher major adverse cardiovascular event rates in comparison to antegrade-only crossing, retrograde percutaneous coronary intervention remains critical for achieving overall high success rates.


Assuntos
Oclusão Coronária/terapia , Intervenção Coronária Percutânea/métodos , Idoso , Distribuição de Qui-Quadrado , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
16.
Catheter Cardiovasc Interv ; 88(7): 1067-1074, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27259089

RESUMO

BACKGROUND: The Flash Ostial system (Ostial Corporation, Sunnyvale, CA) was designed to optimize implantation of aorto-ostial coronary stents by flaring the proximal stent struts against the aortic wall. METHODS: We retrospectively reviewed the medical record, angiograms, and intravascular ultrasound images of 22 aorto-ostial percutaneous coronary interventions performed at our institution between March and September 2015. The Flash Ostial system was used in 13 cases (59%). RESULTS: Mean age was 67 ± 8 years and all patients were men. The target vessel was the right coronary artery (59%), left main (27%), or a saphenous vein graft (14%); 59% of the lesions had moderate/severe calcification. The mean number of predilation balloons was 1.8 ± 1.6, mean Flash ostial balloon diameter was 3.3 ± 0.5 mm and mean inflation pressure was 13.1 ± 4.0 atmospheres. Intravascular ultrasonography (available for 19 patients) revealed mean ostial minimum lumen cross-sectional area (MLA) of 9.2 ± 3.0 mm2 and reference MLA of 8.5 ± 2.7 mm2 . The percent difference between ostial and reference MLA was higher in cases in which the Flash Ostial system was used versus those where it was not (9.6 ± 5.5% vs. 4.0 ± 2.8%, P = 0.03). All stent struts were well apposed. Technical success was 100%. One patient developed a left groin pseudoaneurysm treated with thrombin injection and one patient had a periprocedural myocardial infarction. Median contrast, fluoroscopy time, and procedure time were 235 mL, 33 min, and 118 min, respectively. CONCLUSIONS: The Flash Ostial system can be successfully used in aorto-ostial stenting, resulting in large ostial vessel MLA. © 2016 Wiley Periodicals, Inc.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Oclusão de Enxerto Vascular/terapia , Idoso , Falso Aneurisma/tratamento farmacológico , Falso Aneurisma/etiologia , Angioplastia Coronária com Balão/efeitos adversos , Meios de Contraste/administração & dosagem , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Fluoroscopia , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Veia Safena/diagnóstico por imagem , Veia Safena/transplante , Stents , Texas , Trombina/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
17.
Int J Cardiol ; 219: 38-40, 2016 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-27262231

RESUMO

OBJECTIVES: We sought to explore the accuracy of remote chest X-ray reading using hands-free, wearable technology (Google Glass, Google, Mountain View, California). METHODS: We compared interpretation of twelve chest X-rays with 23 major cardiopulmonary findings by faculty and fellows from cardiology, radiology, and pulmonary-critical care via: (1) viewing the chest X-ray image on the Google Glass screen; (2) viewing a photograph of the chest X-ray taken using Google Glass and interpreted on a mobile device; (3) viewing the original chest X-ray on a desktop computer screen. One point was given for identification of each correct finding and a subjective rating of user experience was recorded. RESULTS: Fifteen physicians (5 faculty and 10 fellows) participated. The average chest X-ray reading score (maximum 23 points) as viewed through the Google Glass, Google Glass photograph on a mobile device, and the original X-ray viewed on a desktop computer was 14.1±2.2, 18.5±1.5 and 21.3±1.7, respectively (p<0.0001 between Google Glass and mobile device, p<0.0001 between Google Glass and desktop computer and p=0.0004 between mobile device and desktop computer). Of 15 physicians, 11 (73.3%) felt confident in detecting findings using the photograph taken by Google Glass as viewed on a mobile device. CONCLUSION: Remote chest X-ray interpretation using hands-free, wearable technology (Google Glass) is less accurate than interpretation using a desktop computer or a mobile device, suggesting that further technical improvements are needed before widespread application of this novel technology.


Assuntos
Radiografia Torácica/normas , Radiologistas/normas , Telemedicina/normas , Telefone Celular/normas , Humanos , Radiografia Torácica/métodos , Telemedicina/métodos , Raios X
18.
Cardiovasc Revasc Med ; 17(7): 444-449, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27133499

RESUMO

BACKGROUND: There is limited information on optical coherence tomography (OCT) findings after percutaneous coronary intervention (PCI) of chronic total occlusions (CTOs). OCT allows high resolution imaging that can enhance understanding of the vascular response after stenting of chronically occluded vessels. METHODS: The Angiographic Evaluation of the Everolimus-Eluting Stent in Chronic Total Occlusions (ACE-CTO) study collected angiographic and clinical outcomes from 100 patients undergoing CTO PCI with the everolimus-eluting stent (EES). OCT was performed 8-months post stenting in 62 patients. Every third frame was analyzed throughout the course of the stented arterial segment. Lumen contours were semi-automatically traced and stent struts were manually delineated, with automatic measurement of the strut to lumen distance. Struts on the luminal side of the lumen contour were classified as malapposed if the distance to the lumen contour exceeded 0.108mm. RESULTS: A total of 44,450 struts in 6047 frames were analyzed, of which 4113 9.3%, 95% confidence intervals [CI] 9.0% to 9.5%) were malapposed and 1230 (2.8%, 95% CI 2.6% to 2.9%) were uncovered. Fifty-five of 62 patients (88.7%, 95% CI 78.5% to 98.4%) had at least one malapposed stent strut and 50 patients (80.7%, 95% CI 69.2% to 88.6%) had at least one uncovered stent strut. Mean strut-intimal thickness of the apposed and malapposed struts was 0.126±0.140mm and -0.491±0.440mm, respectively. CONCLUSION: High rates of stent strut malapposition and incomplete stent strut coverage were observed after CTO PCI using EES, highlighting unique challenges associated with stent implantation in CTOs.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Everolimo/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Tomografia de Coerência Óptica , Idoso , Doença Crônica , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento , Cicatrização
19.
J Invasive Cardiol ; 28(6): 218-24, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27236005

RESUMO

BACKGROUND: The use of saphenous vein grafts (SVGs) for retrograde native-vessel chronic total occlusion (CTO) percutaneous coronary intervention (PCI) has received limited study. METHODS: We retrospectively reviewed the medical records and coronary angiograms of retrograde CTO-PCI performed through an SVG at four United States institutions between 2012 and 2013. RESULTS: During the study period, retrograde CTO-PCI was performed in 144 of 572 cases (25.2%) and retrograde CTO-PCI via SVG in 21 patients (14.6% of all retrograde cases). Mean age was 71 ± 7 years and 95.2% of the patients were men. The CTO target vessel was the right coronary (38%), circumflex (38%), and left anterior descending (24%) artery. Mean J-CTO score was 3.5 ± 1.0. The most common reentry technique was reverse controlled antegrade dissection and reentry. Technical and procedural success rates were 86% and 81%, respectively, with retrograde SVG-PCI attempts being successful in 67%. A major adverse cardiac event occurred in 2 patients (1 periprocedural myocardial infarction and 1 tamponade resulting in death). Median contrast volume, fluoroscopy time, and procedure time were 250 mL, 91.6 minutes, and 214 minutes, respectively. Two SVGs were coiled due to competitive flow after CTO recanalization. CONCLUSION: Retrograde native-vessel CTO-PCI via SVG represents a small proportion of retrograde CTO-PCIs and was associated with high technical success rates, but may carry increased risk for complications.


Assuntos
Oclusão Coronária/cirurgia , Vasos Coronários/cirurgia , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Veia Safena/transplante , Idoso , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
20.
J Invasive Cardiol ; 28(8): 306-10, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27101970

RESUMO

BACKGROUND: We prospectively examined the impact of side-holes and guide-catheter disengagement on fractional flow reserve (FFR) measurements. METHODS: Twenty-five patients undergoing clinically indicated FFR measurement for intermediate coronary artery stenosis were enrolled. Four FFR measurements were made in random order during intravenous adenosine infusion with: (a) an engaged side-hole guide catheter; (b) a disengaged side-hole guide catheter; (c) an engaged non-side-hole guide catheter; and (d) disengaged non-side-hole guide catheter. RESULTS: Mean patient age was 65 ± 9 years and 100% were men. The mean distal poststenotic pressure/proximal aortic pressure (Pd/Pa) at baseline was 0.93 ± 0.05 mm Hg. Using intravenous adenosine infusion, the mean FFR measured with engaged vs disengaged non-side-hole guide catheters was 0.87 ± 0.09 vs 0.83 ± 0.10, respectively (mean difference, 0.039 ± 0.04; P<.001). The mean FFR with engaged vs disengaged side-hole guide catheters was 0.85 ± 0.10 vs 0.83 ± 0.10 (mean difference, 0.020 ± 0.02; P<.001). The mean difference in FFR measurements was 0.024 ± 0.03 (P<.001) among engaged guide catheters and 0.005 ± 0.03 (P=.47) among disengaged guide catheters. CONCLUSIONS: When FFR measurements are performed with engaged guide catheters, side-hole catheters provide lower measurements. When FFR measurements are obtained with disengaged guide catheters, they are even lower and similar between guide catheter types.


Assuntos
Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Idoso , Pressão Arterial/efeitos dos fármacos , Pressão Arterial/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Angiografia Coronária/métodos , Vasos Coronários/fisiopatologia , Precisão da Medição Dimensional , Humanos , Hiperemia/diagnóstico , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Dispositivos de Acesso Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...