1.
Invest Radiol ; 51(4): 249-54, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26606552

RESUMO

OBJECTIVES: Spectral optimization of x-ray computed tomography (CT) has led to substantial radiation dose reduction in contrast-enhanced CT studies using standard iodinated contrast media. The purpose of this study was to analyze the potential for further dose reduction using high-atomic-number elements such as hafnium and tungsten. As in previous studies, spectra were determined for which the patient dose necessary to provide a given contrast-to-noise ratio (CNR) is minimized. MATERIALS AND METHODS: We used 2 different quasi-anthropomorphic phantoms representing the liver cross-section of a normal adult and an obese adult patient with the lateral widths of 360 and 460 mm and anterior-posterior heights of 200 and 300 mm, respectively. We simulated and measured on 2 different scanners with x-ray spectra from 80 to 140 kV and from 70 to 150 kV, respectively. We determined the contrast for iodine-, hafnium-, and tungsten-based contrast media, the noise, and 3-dimensional dose distributions at all available tube voltages by measurements and by simulations. The dose-weighted CNR was determined as optimization parameter. RESULTS: Simulations and measurements were in good agreement regarding their dependence on energy for all parameters investigated. Hafnium provided the best performance for normal and for obese patient phantoms, indicating a dose reduction potential of 30% for normal and 50% for obese patients at 120 kV compared with iodine; this advantage increased further with higher kV values. Dose-weighted CNR values for tungsten were always slightly below the hafnium results. Iodine proved to be the superior choice at voltage values of 80 kV and below. DISCUSSION: Hafnium and tungsten both seem to be candidates for contrast-medium-enhanced CT of normal and obese adult patients with strongly reduced radiation dose at unimpaired image quality. Computed tomography examinations of obese patients will decrease in dose for higher kV values.


Assuntos
Meios de Contraste/química , Doses de Radiação , Tomografia Computadorizada por Raios X , Háfnio/química , Humanos , Iodo/química , Fígado , Obesidade , Imagens de Fantasmas , Tungstênio/química
2.
J Med Imaging (Bellingham) ; 2(3): 034001, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26240833

RESUMO

Various applications require information on breast parameters, such as breast length and volume. An optical system was designed and tested for measuring these parameters with subjects in a prone position. The study results were used for optimizing patient positioning and handling for a future breast computed tomography (BCT) system. Measurements were conducted using an optical measurement system. To test the functionality and accuracy of the system, measurements were performed using reference phantoms. Additionally, 20 women and 5 men were examined to calculate breast parameters in alternative positions and breathing states. The results of the optical measurements were compared with magnetic resonance imaging (MRI) measurements. Volume and length of the reference phantoms were determined with errors below 2%. The patient study demonstrated a mean breast volume of 530.7 ml for women during normal breathing. During an exhalation state, breast volume increased significantly by 17.7 ml in comparison with normal breathing. Differences with MRI measurements were found to be 3% for breast length and 9% for breast volume on average. The proposed optical measurement system was found to be suitable for measuring the dimensional parameters of the breast in a prone position and provides a tool for evaluating breast coverage for BCT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...