Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 290
Filtrar
1.
Circ Cardiovasc Interv ; : e014143, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38853766

RESUMO

Bioprosthetic aortic valve thrombosis is frequently detected after transcatheter and surgical aortic valve replacement due to advances in cardiac computed tomography angiography technology and standardized surveillance protocols in low-surgical-risk transcatheter aortic valve replacement trials. However, evidence is limited concerning whether subclinical leaflet thrombosis leads to clinical adverse events or premature structural valve deterioration. Furthermore, there may be net harm in the form of bleeding from aggressive antithrombotic treatment in patients with subclinical leaflet thrombosis. This review will discuss the incidence, mechanisms, diagnosis, and optimal management of bioprosthetic aortic valve thrombosis after transcatheter aortic valve replacement and bioprosthetic surgical aortic valve replacement.

3.
Am J Cardiol ; 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38871158

RESUMO

The benefit of mechanical circulatory support (MCS) with Impella (Abiomed, Inc., Danvers, MA) for high-risk percutaneous coronary intervention (HR-PCI) is uncertain. PROTECT III registry data showed improved outcomes with Impella compared to historical data (PROTECT II) but lacks a direct comparison to the HR-PCI cohort without Impella support. We retrospectively identified patients meeting PROTECT III inclusion criteria for HR-PCI and compared this group (NonIMP) to the outcomes data from the PROTECT III registry (IMP). Baseline differences were balanced using inverse propensity weighting (IPW). The co-primary outcome was major adverse cardiac events (MACE) in-hospital and at 90 days. A total of 283 high-risk patients who did not receive Impella support; 200 patients had at 90-day event ascertainment and were included in the IPW analysis and compared with 504 patients in the IMP group. After calibration, few residual differences remained between groups. The primary outcome was not different in-hospital (3.0% vs. 4.8%, p=0.403) but lower in NonIMP at 90 days (7.5% vs. 13.8%, p=0.033). Periprocedural vascular complications, bleeding, and transfusion rate were not different between groups; however, acute kidney injury occurred more frequently in the NonIMP group (10.5% vs. 5.4%, p=0.023). In conclusion, under identical HR-PCI inclusion criteria for Impella use in PROTECT III, an institutional non-Impella-supported HR-PCI cohort demonstrated similar MACE in-hospital but lower MACE at 90 days, while there was no signal for periprocedural harm with Impella use. These results do not support routine usage of Impella for HR-PCI patients.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38769727

RESUMO

BACKGROUND: The Evolut self-expanding valve (SEV) systems (Medtronic), were designed to accommodate varying valve sizes and reduce paravalvular leak (PVL) while maintaining a low delivery profile. These systems have evolved between product generations, alongside valve deployment techniques changing over time. AIMS: This study aimed to examine whether these changes impacted clinical outcomes. METHODS: EPROMPT is a prospective, investigator-initiated, postmarketing registry of consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) using the Evolut PRO/PRO+ SEV system. A total of 300 patients were divided into three consecutive cohorts of 100 patients according to implantation date (January to October 2018, November 2018 to July 2020, and August 2020 to November 2021). Procedural and clinical outcomes over these time periods were compared. RESULTS: Valve Academic Research Consortium (VARC)-2 device implantation success improved over time (70.0% vs. 78.0% vs. 88.8%, p = 0.01), with a similar trend for VARC-3 device success (94.7% vs. 81.7% vs. 96.8%, p < 0.001). PVL (all degrees) frequency was likewise reduced over time (31.0% vs. 17.0% vs. 19.2%, p = 0.04). Furthermore, a trend was noticed toward shorter procedure times and shorter length of stay. However, postprocedural pacemaker implantation rates did not significantly differ (15.2% vs. 21.1% vs. 14.0%, p = 0.43). CONCLUSION: During a 3-year period, we demonstrated better TAVR outcomes with newer SEV iterations, alongside changes in implantation techniques, which might result in better procedural and clinical outcomes. However, we did not see a significant change in peri-procedural pacemaker rates for SEV.

5.
JACC Clin Electrophysiol ; 10(5): 814-825, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38811066

RESUMO

BACKGROUND: Deep intramural ventricular tachycardia substrate targets are difficult to access, map, and ablate from endocardial and epicardial surfaces, resulting in high recurrence rates. OBJECTIVES: In this study, the authors introduce a novel approach called ventricular intramyocardial navigation for tachycardia ablation guided by electrograms (VINTAGE) to access and ablate anatomically challenging ventricular tachycardia from within the myocardium. METHODS: Guidewire/microcatheter combinations were navigated deep throughout the extravascular myocardium, accessed directly from the right ventricle cavity, in Yorkshire swine (6 naive, 1 infarcted). Devices were steered to various intramyocardial targets including the left ventricle summit, guided by fluoroscopy, unipolar electrograms, and/or electroanatomic mapping. Radiofrequency ablations were performed to characterize ablation parameters and reproducibility. Intramyocardial saline irrigation began 1 minute before ablation and continued throughout. Lesions were analyzed on cardiac magnetic resonance and necropsy. RESULTS: VINTAGE was feasible in all animals within naive and infarcted myocardium. Forty-three lesions were created, using various guidewires and power settings. Forty-one (95%) lesions were detected on cardiac magnetic resonance and 38 (88%) on necropsy; all undetected lesions resulted from intentionally subtherapeutic ablation energy (10 W). Larger-diameter guidewires yielded larger size lesions. Lesion volumes on necropsy were significantly larger at 20 W than 10 W (178 mm3 [Q1-Q3: 104-382 mm3] vs 49 mm3 [Q1-Q3: 35-93 mm3]; P = 0.02). Higher power (30 W) did not create larger lesions. Median impedance dropped with preablation irrigation by 12 Ω (Q1-Q3: 8-17 Ω), followed by a further 15-Ω (Q1-Q3: 11-19 Ω) drop during ablation. Intramyocardial navigation, ablation, and irrigation were not associated with any complications. CONCLUSIONS: VINTAGE was safe and effective at creating intramural ablation lesions in targets traditionally considered inaccessible from the endocardium and epicardium, both naive and infarcted. Intramyocardial guidewire irrigation and ablation at 20 W creates reproducibly large intramural lesions.


Assuntos
Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Ventricular , Animais , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Suínos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/cirurgia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem
6.
J Am Heart Assoc ; 13(11): e032291, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38818933

RESUMO

BACKGROUND: Hemoglobin (Hgb) drop without bleeding is common among patients undergoing transcatheter aortic valve replacement; however, the clinical implications of significant Hgb drop have not been fully evaluated. METHODS AND RESULTS: Consecutive patients undergoing transcatheter aortic valve replacement at our institution from 2011 to 2021 were retrospectively reviewed. Three groups were assessed: no Hgb drop and no bleed (NoD-NoB [reference group]), Hgb drop with bleed, and Hgb drop and no bleed (D-NoB). Hgb drop was defined as ≥3 g/dL decrease from pre- to post-transcatheter aortic valve replacement. Outcomes of interest were in-hospital death and 1-year all-cause mortality. A total of 1851 cases with complete Hgb data were included: NoD-NoB: n=1579 (85.3%); D-NoB: n=49 (2.6%); Hgb drop with bleed: n=223 (12.6%). Compared with NoD-NoB, the D-NoB group was older (81.1 versus 78.9 years of age) with higher preprocedure Hgb (12.9 versus 11.7 g/dL). In-hospital death rate was higher among patients with D-NoB versus NoD-NoB (4.5% versus 0.8%, P<0.001) and similar to Hgb drop with bleed (4.5% versus 4.1%, P=0.999). Predictors of in-hospital death were D-NoB (odds ratio [OR], 3.45 [95% CI, 1.32-8.69]) and transfusion (OR, 10.6 [95% CI, 4.25-28.2]). Landmark survival analysis found that D-NoB experienced 1-year mortality rate comparable to NoD-NoB, whereas Hgb drop with bleed had higher midterm mortality (hazard ratio [HR], 3.2 [95% CI, 1.83-5.73]), and transfusion continued to impact mortality (HR, 2.5 [95% CI, 1.79-3.63]). CONCLUSIONS: Hgb drop without bleeding is common among patients undergoing transcatheter aortic valve replacement and may represent a higher risk of periprocedural death. Blood transfusion increases short- and midterm mortality risk in patients with and without bleeding, supporting a restrictive transfusion strategy.


Assuntos
Estenose da Valva Aórtica , Hemoglobinas , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estudos Retrospectivos , Hemoglobinas/metabolismo , Hemoglobinas/análise , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Fatores de Risco , Resultado do Tratamento , Medição de Risco/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-38797580

RESUMO

BACKGROUND: Outflow graft obstruction (OGO) is an uncommon yet life-threatening complication in patients with left ventricular assist devices (LVADs). In this retrospective, single-center case series, we identify the baseline demographics and presenting features of patients who develop LVAD OGO and the procedural details and outcomes surrounding percutaneous endovascular intervention (PEI). METHODS: We conducted a retrospective review of patients with LVADs at our institution between January 2010 and February 2023 who developed OGO and were treated with PEI. Details of the PEI including procedure time, fluoroscopy time, contrast use, stent size, number of stents, change in gradient, and change in flow after intervention were collected. RESULTS: A total of 12 patients who had 14 cases of OGO were identified from January 2010 to February 2023. The average age at presentation was 64.78 years. Nine of the 14 cases occurred in male patients. Eleven of the 14 cases occurred with Heartware devices (2 recurrences), 2 in Heartmate 2 and 1 in Heartmate 3. Notable procedural details include a mean procedure time of 90.86 min and mean contrast use of 162.5 mL. The initial gradient across the OGO was reduced by an average of 72 %, to a mean post-PEI of 11.57 mmHg. The average number of stents to achieve this gradient was around 2.08, with the most common stent diameter being 10 mm. Thirty-day mortality after PEI was 7 % (1/14) in this high-risk patient population. CONCLUSION: In our single-center experience, PEI can be a safe and effective treatment for LVAD OGO.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38719633

RESUMO

BACKGROUND: High-sensitivity troponin (hsTnI) is correlated with cardiac mortality; however, studies on the relationship of markedly elevated hsTnI with in-hospital mortality after cardiac surgery are sparse. Therefore, we aimed to define this relationship in order to help guide in-hospital, acute management of post-surgical patients. METHODS: We retrospectively analyzed all cardiac surgeries completed at our institution between January 2020 and June 2022 in which a peak hsTnI was noted to be >35× upper limit of normal (ULN = 34 ng/L). The primary outcome was in-hospital death. Subgroup analysis was performed to assess differences between coronary artery bypass grafting (CABG) and other cardiac surgeries. RESULTS: A total of 1382 cases met inclusion criteria. The patients' mean age was 64.8 years and 68.2 % were male. Median peak hsTnI after surgery was 4202 ng/L (interquartile ratio: 2427-7654). Univariate analysis of troponin level with mortality found that for every 1000 ng/L increase in hsTnI, odds of in-hospital death increased by 3.8 % (odds ratio [OR]: 1.038; 95 % confidence interval [CI] 1.027-1.050; p < 0.0001). In a multivariate model, troponin (OR 1.02; 95 % CI 1.01-1.04; p = 0.004) maintained a significant association with in-hospital death. CABG was associated with a lower risk of in-hospital death for any given hsTnI level up to 60,000 ng/L compared to other cardiac surgeries. CONCLUSION: Increasing hsTnI level is associated with increasing probability of in-hospital mortality and, therefore, serves as an additional, objective measure of risk to help guide in-hospital clinical management.

9.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38639328

RESUMO

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Assuntos
Estenose da Valva Aórtica , Alta do Paciente , Readmissão do Paciente , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/tendências , Readmissão do Paciente/estatística & dados numéricos , Readmissão do Paciente/tendências , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Idoso , Alta do Paciente/tendências , Sistema de Registros , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/tendências , Fatores de Tempo , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Estados Unidos/epidemiologia , Fatores de Risco , Valva Aórtica/cirurgia , Estudos Retrospectivos , Desenho de Prótese , Medição de Risco
10.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38587261

RESUMO

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Idoso , Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Estimativa de Kaplan-Meier , Acidente Vascular Cerebral/etiologia , Insuficiência Cardíaca , Complicações Pós-Operatórias/etiologia , Falha de Prótese
11.
Catheter Cardiovasc Interv ; 103(6): 917-923, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38605682

RESUMO

The advent of excimer laser coronary atherectomy (ELCA) nearly four decades ago heralded a novel way to treat complex lesions, both coronary and peripheral, which were previously untraversable and thus untreatable. These complex lesions include heavily calcified lesions, ostial lesions, bifurcation lesions, chronic total occlusions, in-stent restenosis (including stent underexpansion), and degenerative saphenous vein grafts. We discuss the technology of ELCA, its indications, applications, and complications, and suggest the "MAXCon ELCA" technique for better outcomes without increased risk. Lastly, we present a case of MAXCon ELCA effectively treating a complex lesion.


Assuntos
Aterectomia Coronária , Angiografia Coronária , Doença da Artéria Coronariana , Lasers de Excimer , Humanos , Meios de Contraste , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Lasers de Excimer/uso terapêutico , Solução Salina/administração & dosagem , Resultado do Tratamento
13.
J Fish Biol ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38533638

RESUMO

Migration is a critical aspect of ocean ecosystems, and understanding this phenomenon answers ecological and management questions. Given the difficulty in tracking ocean animals across large distances, the extent to which different ray species perform long-distance movements, such as migrations, remains unknown. This study used passive acoustic telemetry to track the movements of endemic diamond Gymnura natalensis and critically endangered duckbill Aetomylaeus bovinus rays along the South African coastline using a collaborative nationwide network of coastal acoustic receivers for up to 7 years. Duckbill rays were detected significantly more frequently than diamond rays, but both species moved between the south and east coasts of South Africa (traveling up to 1167 km). Tagged individuals were detected significantly more often in their tagging locations during summer months but traveled significantly further distances during winter months. Furthermore, movement models fitted to individual duckbill rays' annual net-squared displacement identified most individual annual movements as migratory. This evidence suggests that both diamond and duckbill rays make eastward winter migrations and return to specific areas along the coastline during the summer months. The exceptions to this were diamond rays tagged on the east coast that were not found to migrate seasonally, which supports previous research that there is intraspecific variability in migrations for ray species. These findings have implications for understanding ray migration not only on a global scale but also locally for spatial management interventions and population delineation.

14.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38471643

RESUMO

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Assuntos
Cardiomiopatia Hipertrófica , Implante de Prótese de Valva Cardíaca , Miotomia , Obstrução da Via de Saída Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo , Humanos , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Retrospectivos , Cateterismo Cardíaco/métodos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Resultado do Tratamento , Cardiomiopatia Hipertrófica/complicações , Miotomia/efeitos adversos
15.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38533653

RESUMO

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Assuntos
Insuficiência da Valva Aórtica , Valvuloplastia com Balão , Modelos Animais de Doenças , Hemodinâmica , Animais , Hemodinâmica/efeitos dos fármacos , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Sus scrofa , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Desenho de Equipamento , Recuperação de Função Fisiológica , Doença Aguda , Cateteres Cardíacos , Fatores de Tempo , Índice de Gravidade de Doença , Função Ventricular Esquerda/efeitos dos fármacos
17.
Cardiovasc Revasc Med ; 59: 9-13, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37550124

RESUMO

BACKGROUND/PURPOSE: The cusp overlap technique has standardized implantation for self-expanding valves with the goal of achieving more consistent implantation depths and lowering permanent pacemaker (PPM) implantation rates. We retrospectively compared short-term outcomes in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expanding valve implanted using the cusp overlap technique vs. the traditional coplanar technique in a large tertiary referral center. METHODS: We conducted a retrospective study among PPM-naïve patients who underwent TAVR using the CoreValve Evolut PRO/PRO+. We compared in-hospital PPM rates in patients who underwent TAVR using the cusp overlap technique vs. the coplanar technique. Additional outcomes included in-hospital all-cause mortality, stroke, major vascular complications, annular rupture, and >mild paravalvular leak. Furthermore, we compared outcomes over time to see whether there was evidence of a learning curve. RESULTS: Of the 528 patients included, 270 underwent TAVR using the coplanar technique and 258 underwent TAVR using the cusp overlap technique. The rate of new PPM implantation did not differ between cohorts (17.0 % vs. 16.7 %; p = 0.910). Additionally, rates of in-hospital all-cause mortality (0.0 % vs. 0.4 %; p = 0.328), stroke (3.7 % vs. 1.6 %; p = 0.124), major vascular complications (0.7 % vs. 1.2 %; p = 0.617), annular rupture (0.4 % vs. 0.0 %; p = 0.328) and >mild paravalvular leak (0.0 % vs. 0.4 %; p = 0.444) were similar. Our secondary analysis did not identify any evidence of a learning curve. CONCLUSIONS: The cusp overlap technique may not yield a reduction in PPM rates when compared with the coplanar technique. Other confounders should be explored to further minimize in-hospital PPM rates.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco , Desenho de Prótese
18.
Cardiovasc Revasc Med ; 59: 76-80, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37689575

RESUMO

BACKGROUND: Computed tomography with fractional flow reserve (CT-FFR) is increasingly common in assessing coronary artery disease. CASE PRESENTATION: We report five cases of discrepancies that led to changes in treatment. CONCLUSIONS: This report highlights discordant findings between modalities, which should be considered during the diagnostic assessment of chest pain.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Humanos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Angiografia Coronária/métodos , Sensibilidade e Especificidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Estudos Retrospectivos
19.
Cardiovasc Revasc Med ; 58: 45-49, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37393190

RESUMO

PURPOSE: Explore gender disparities in patients undergoing transseptal puncture (TSP) for selected transcatheter cardiac intervention procedures. METHODS: Patients who underwent TSP from January 2015 through September 2021 were reviewed. Primary outcomes were procedural and in-hospital major adverse events. Secondary endpoints were procedural success and hospitalization length of stay (LOS) >1 day. Unadjusted and multivariable-adjusted logistic regression analyses were performed to assess gender differences for in-hospital adverse events. RESULTS: The study cohort comprised 510 patients (mean [SD] age, 74 [14.0] years); 246 women (48 %) underwent TSP for left atrial appendage occlusion (LAAO) or transcatheter edge-to-edge-repair (TEER). Compared with men, women were younger, had higher CHA2DS2-VASc scores, and were more likely to have had a prior ischemic stroke, but were less likely to have paroxysmal atrial fibrillation. After multivariable adjustment, there were no differences between genders in aborted or canceled procedures (odds ratio [OR]: 0.43; 95 % confidence interval [CI]: 0.10-1.96; p = 0.277), any adverse events (OR: 1.00; 95 % CI: 0.58-1.70; p = 0.98), major adverse events (OR: 1.60; 95 % CI: 0.90-2.80; p = 0.11), or death (OR: 1.00; 95 % CI: 0.20-5.00; p = 0.31). Subgroup analysis for LAAO procedures showed that at 30 days, women had higher rates of adverse events, major adverse cardiac events, and LOS >1 day. CONCLUSIONS: Men and women showed no differences in procedural success and in-hospital adverse outcomes in unadjusted analysis and after multivariable adjustment, despite women having a higher risk profile among patients undergoing TSP. However, compared with men, women undergoing LAAO experienced a higher rate of in-hospital adverse events irrespective of TSP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , AVC Isquêmico/etiologia , Fatores de Tempo , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia
20.
Int J Cardiol ; 395: 131431, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37832606

RESUMO

BACKGROUND: Recent randomized studies have broadened the indication of transcatheter aortic valve replacement (TAVR) to also include low-surgical-risk patients. However, the data on self-expanding (SE) and balloon-expandable (BE) valves in low-risk patients remain sparse. METHODS: The current study is a post hoc analysis of combined data from both LRT 1.0 and 2.0 trials comparing BE and SE transcatheter heart valves. RESULTS: A total of 294 patients received a BE valve, and 102 patients received an SE valve. The 30-day clinical outcomes were similar across both groups except for stroke (4.9% vs. 0.7%, p = 0.014) and permanent pacemaker implantation (17.8% vs. 5.8%, p < 0.001), which were higher in the SE cohort than the BE cohort. No difference was observed in terms of paravalvular leak (≥moderate) between the groups (0% vs. 1.5%, p = 0.577). SE patients had higher aortic valve area (1.92 ± 0.43 mm2 vs. 1.69 ± 0.45 mm2, p < 0.001) and lower mean gradient (8.93 ± 3.53 mmHg vs. 13.41 ± 4.73 mmHg, p < 0.001) than BE patients. In addition, the rate of subclinical leaflet thrombosis was significantly lower in SE patients (5.6% vs. 13.8%, p = 0.038). CONCLUSION: In this non-randomized study assessing SE and BE valves in low-risk TAVR patients, SE valves are associated with better hemodynamics and lesser leaflet thrombosis, with increased rates of stroke and permanent pacemaker implantation at 30 days; however, this could be due to certain patient-dependent factors not fully evaluated in this study. The long-term implications of these outcomes on structural valve durability remain to be further investigated. CLINICAL TRIAL REGISTRY: LRT 1.0: NCT02628899 LRT 2.0: NCT03557242.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Desenho de Prótese , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...