Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med ; 123: 103394, 2024 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-38852364

RESUMO

PURPOSE: To present the results of the first multi-centre real-world validation of autoplanning for whole breast irradiation after breast-sparing surgery, encompassing high complexity cases (e.g. with a boost or regional lymph nodes) and a wide range of clinical practices. METHODS: The 24 participating centers each included 10 IMRT/VMAT/Tomotherapy patients, previously treated with a manually generated plan ('manplan'). There were no restrictions regarding case complexity, planning aims, plan evaluation parameters and criteria, fractionation, treatment planning system or treatment machine/technique. In addition to dosimetric comparisons of autoplans with manplans, blinded plan scoring/ranking was conducted by a clinician from the treating center. Autoplanning was performed using a single configuration for all patients in all centres. Deliverability was verified through measurements at delivery units. RESULTS: Target dosimetry showed comparability, while reductions in OAR dose parameters were 21.4 % for heart Dmean, 16.7 % for ipsilateral lung Dmean, and 101.9 %, 45.5 %, and 35.7 % for contralateral breast D0.03cc, D5% and Dmean, respectively (all p < 0.001). Among the 240 patients included, the clinicians preferred the autoplan for 119 patients, with manplans preferred for 96 cases (p = 0.01). Per centre there were on average 5.0 ± 2.9 (1SD) patients with a preferred autoplan (range [0-10]), compared to 4.0 ± 2.7 with a preferred manplan ([0,9]). No differences were observed regarding deliverability. CONCLUSION: The automation significantly reduced the hands-on planning workload compared to manual planning, while also achieving an overall superiority. However, fine-tuning of the autoplanning configuration prior to clinical implementation may be necessary in some centres to enhance clinicians' satisfaction with the generated autoplans.

2.
Phys Med ; 32(7): 866-73, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27262921

RESUMO

PURPOSE: To establish the reliability and accuracy of a UNIQUE Linac in delivering RapidArc treatments and assess its long term stability. MATERIALS AND METHODS: UNIQUE performance was monitored and analyzed for a period of nearly two years. 2280 Dynalog files, related to 179 clinical RapidArc treatments were collected. Different tumor sites and dose scheduling were included, covering the full range of our treatment plans. Statistical distributions of MLC motion error, gantry rotation error and MU delivery error were evaluated. The stochastic and systematic nature of each error was investigated together with their variation in time. RESULTS: All the delivery errors are found to be small and more stringent tolerances than those proposed by TG142 are suggested. Unlike MLC positional errors, where a linear relationship with leaf speed holds, other Volumetric Modulated Arc Therapy (VMAT) parameters reveal a random nature and, consequently, a reduced clinical relevance. MLC errors are linearly related only to leaf speed no matter the shape of the MLC apertures. Gantry rotation and MU delivery are as accurate as major competing Linacs. UNIQUE was found to be reliable and accurate throughout the investigation period, regardless of the specific tumor sites and fractionation schemes. CONCLUSIONS: The accuracy of RapidArc treatments delivered with UNIQUE has been established. The stochastic nature of delivery errors is proven. Long term statistics of the delivery parameter errors do not show significant variations, confirming the reliability of the VMAT delivery system.


Assuntos
Radioterapia de Intensidade Modulada/métodos , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Aceleradores de Partículas , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada/instrumentação , Rotação , Fatores de Tempo
3.
J Dairy Sci ; 99(8): 6446-6456, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27265177

RESUMO

Mastitis due to intramammary infections is one of the most detrimental diseases in dairy sheep farming, representing a major cause of reduced milk productions and quality losses. In particular, subclinical mastitis presents significant detection and control problems, and the availability of tools enabling its timely, sensitive, and specific detection is therefore crucial. We have previously demonstrated that cathelicidins, small proteins implicated in the innate immune defense of the host, are specifically released in milk of mastitic animals by both epithelial cells and neutrophils. Here, we describe the development of an ELISA for milk cathelicidin and assess its value against somatic cell counts (SCC) and bacteriological culture for detection of ewe mastitis. Evaluation of the cathelicidin ELISA was carried out on 705 half-udder milk samples from 3 sheep flocks enrolled in a project for improvement of mammary health. Cathelicidin was detected in 35.3% of milk samples (249/705), and its amount increased with rising SCC values. The cathelicidin-negative (n=456) and cathelicidin-positive (n=249) sample groups showed a clear separation in relation to SCC, with median values of 149,500 and 3,300,000 cells/mL, respectively. Upon bacteriological culture, 20.6% (145/705) of the milk samples showed microbial growth, with coagulase-negative staphylococci being by far the most frequent finding. A significant proportion of all bacteriologically positive milk samples were positive for cathelicidin (110/145, 75.9%). Given the lack of a reliable gold standard for defining the true disease status, sensitivity (Se) and specificity (Sp) of the cathelicidin ELISA were assessed by latent class analysis against 2 SCC thresholds and against bacteriological culture results. At an SCC threshold of 500,000 cells/mL, Se and Sp were 92.3 and 92.3% for cathelicidin ELISA, 89.0 and 94.9% for SCC, and 39.4 and 93.6% for bacteriological culture, respectively. At an SCC threshold of 1,000,000 cells/mL, Se and Sp were 93.3 and 91.9% for cathelicidin ELISA, 80.0 and 97.1% for SCC, and 39.4 and 93.5% for bacteriology, respectively. In view of the results obtained in this study, the measurement of cathelicidin in milk by ELISA can provide added Se while maintaining a high Sp and may therefore improve detection of subclinical mastitis.


Assuntos
Mastite/veterinária , Leite/microbiologia , Animais , Contagem de Células/veterinária , Feminino , Glândulas Mamárias Animais/microbiologia , Ovinos , Staphylococcus
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...