Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rofo ; 187(1): 49-55, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25226234

RESUMO

PURPOSE: An extensive analysis of the value of computed tomography (CT) parameters as potential predictors of the clinical outcome of type 2 endoleaks after endovascular aortic aneurysm repair (EVAR). MATERIALS AND METHODS: Initial CT scans of 130 patients with abdominal aortic aneurysms (AAAs) were retrospectively reviewed. On the basis of postoperative CT scans and angiographies, patients were stratified into a low-risk group (LRG; without or transient type 2 endoleak; n = 80) and a high-risk group (HRG, persistent type 2 endoleak or need for reintervention; n = 50). Statistical analysis comprised a univariate and multivariate analysis. RESULTS: Anatomical, thrombus-specific, as well as aortic side branch parameters were assessed on the initial CT scan. Of all anatomical parameters, the diameter of the immediate infrarenal aorta was significantly different in the univariate analysis (LRG 22.4 ±â€Š3.8 mm; HRG 23.6 ±â€Š2.5 mm; p = 0.03). The investigation of the thrombus-specific parameters showed a trend towards statistical significance for the relative thrombus load (LRG 31.7 ±â€Š18.0%; HRG 25.3 ±â€Š17.5%; p = 0.09). Assessment of aortic side branches revealed only for the univariate analysis significant differences in the patency of the inferior mesenteric artery (LRG 71.3%; HRG 92.0%; p = 0.003) and their diameter (LRG 3.3 ±â€Š0.7 mm; HRG 3.8 ±â€Š0.9 mm; p = 0.004). In contrast, the number of lumbar arteries (LAs; LRG 2.7 ±â€Š1.4; HRG 3.6 ±â€Š1.2; univariate: p = 0.01; multivariate: p = 0.006) as well as their diameter (LRG 2.1 ±â€Š0.4 mm; HRG 2.4 ±â€Š0.4 mm; univariate: p < 0.001; multivariate: p = 0.006) were highly significantly associated with the development of type 2 endoleaks of the HRG. CONCLUSION: The most important predictive factors for the development of high-risk type 2 endoleaks were mainly the number and the diameter of the LAs which perfused the AAA. KEY POINTS: • This study is a very detailed and comprehensive analysis of the value of various CT parameters as potential predictors of the clinical outcome of type 2 endoleaks after EVAR. • Anatomical as well as thrombus-specific parameters were unsuitable as predictors. • The most important predictive factors were mainly the number and the diameter of the LAs which perfused the AAA.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/métodos , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
2.
Rofo ; 185(11): 1081-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23897530

RESUMO

PURPOSE: Assessment of radiologist's hand dose in CT-guided interventions and determination of influencing factors. MATERIALS AND METHODS: The following CT-guided interventions were included: Core biopsy, drainage, periradicular therapy, and celiac plexus neurolysis. The hand dose was measured with an immediately readable dosimeter, the EDD-30 (Unfors, Sweden). The default parameters for CT fluoroscopy were 120 kV, 90 mA and a 4 mm slice thickness. All interventions were performed on a 16-slice CT unit (Aquilion 16 Toshiba, Japan). The tumor size, degree of difficulty (1 - 3), level of experience and device parameters (mAs, dose-length product, scan time) were documented. RESULTS: 138 CT-guided interventions (biopsy n = 99, drainage n = 23, pain therapy n = 16) at different locations (lung n = 41, retroperitoneum n = 53, liver n = 25, spine n = 19) were included. The lesion size was 4 - 240 mm (median: 23 mm). The fluoroscopy time per intervention was 4.6 - 140.2 s (median: 24.2 s). The measured hand dose ranged from 0.001 - 3.02 mSv (median: 0.22 mSv). The median hand dose for lung puncture (n = 41) was slightly higher (median: 0.32 mSv, p = 0.01) compared to that for the liver, retroperitoneum and other. Besides physical influencing factors, the degree of difficulty (p = 0.001) and summed puncture depth (p = 0.004) correlated significantly with the hand dose. CONCLUSION: The median hand dose for different CT-guided interventions was 0.22 mSv. Therefore, the annual hand dose limit would normally only be reached with about 2000 interventions.


Assuntos
Mãos/diagnóstico por imagem , Médicos/estatística & dados numéricos , Doses de Radiação , Radiografia Intervencionista/estatística & dados numéricos , Radiometria/estatística & dados numéricos , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Alemanha/epidemiologia , Mãos/efeitos da radiação , Mãos/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...