Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Arch Plast Surg ; 49(1): 34-38, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35086306

RESUMO

The deep inferior epigastric perforator (DIEP) flap has been widely used for autologous breast reconstruction after mastectomy. In the conventional surgical method, a long incision is needed at the anterior fascia of the rectus abdominis muscle to obtain sufficient pedicle length; this may increase the risk of incisional hernia. To shorten the incision, several trials have investigated the use of endoscopic/robotic devices for pedicle harvest; however, making multiple additional incisions for port insertion and operating in the intraperitoneal field were inevitable. Here, we describe the first case, in which a DIEP free flap was successfully made using the da Vinci SP model. Our findings can help surgeons perform operations in smaller fields with a single port in the extraperitoneal space. Moreover, this method is expected to lead to fewer donor-related complications and faster healing.

3.
Arch Plast Surg ; 45(5): 449-457, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30282416

RESUMO

BACKGROUND: Although previous studies have focused on determining prognostic and causative variables associated with fistula-related complications after head and neck reconstructive surgery, only a few studies have addressed preventive measures. Noting that pooled saliva complicates wound healing and precipitates fistula-related complications, we devised a continuous suction system to remove saliva during early postoperative recovery. METHODS: A continuous suction system was implemented in 20 patients after head and neck reconstructive surgery between January 2012 and October 2017. This group was compared to a control group of 16 patients at the same institution. The system was placed orally when the lesion was on the anterior side of the retromolar trigone area, and when glossectomy or resection of the mouth floor was performed. When the orohypopharynx and/or larynx were eradicated, the irrigation system was placed in the pharyngeal area. RESULTS: The mean follow-up period was 9.2±2.4 months. The Hemovac system was applied for an average of 7.5 days. On average, 6.5 days were needed for the net drain output to fall below 10 mL. Complications were analyzed according to their causes and rates. A fistula occurred in two cases in the suction group. Compared to the control group, a significant difference was noted in the surgical site infection rate (P<0.031). CONCLUSIONS: Clinical observations showed reduced saliva pooling and a reduction in the infection rate. This resulted in improved wound healing through the application of a continuous suction system.

4.
Yonsei Med J ; 58(5): 1031-1039, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28792150

RESUMO

PURPOSE: Most studies on immune tolerance of mesenchymal stem cells (MSCs) have been performed using MSCs derived from bone marrow, cord blood, or adipose tissue. MSCs also exist in the craniofacial area, specifically in teeth. The purpose of this study was to evaluate the mechanisms of immune tolerance of dental pulp-derived MSC (DP-MSC) in vitro and in vivo. MATERIALS AND METHODS: We isolated DP-MSCs from human dental pulp and co-cultured them with CD4⁺ T-cells. To evaluate the role of cytokines, we blocked TGF-ß and IL-10, separately and together, in co-cultured DP-MSCs and CD4⁺ T-cells. We analyzed CD25 and FoxP3 to identify regulatory T-cells (Tregs) by fluorescence-activated cell sorting (FACS) and real-time PCR. We performed alloskin grafts with and without DP-MSC injection in mice. We performed mixed lymphocyte reactions (MLRs) to check immune tolerance. RESULTS: Co-culture of CD4⁺ T-cells with DP-MSCs increased the number of CD4⁺CD25⁺FoxP3⁺ Tregs (p<0.01). TGF-ß or/and IL-10 blocking suppressed Treg induction in co-cultured cells (p<0.05). TGF-ß1 mRNA levels were higher in co-cultured DP-MSCs and in co-cultured CD4⁺ T-cells than in the respective monocultured cells. However, IL-10 mRNA levels were not different. There was no difference in alloskin graft survival rate and area between the DP-MSC injection group and the non-injection group. Nonetheless, MLR was reduced in the DP-MSC injected group (p<0.05). CONCLUSION: DP-MSCs can modulate immune tolerance by increasing CD4⁺CD25⁺FoxP3⁺ Tregs. TGF-ß1 and IL-10 are factors in the immune-tolerance mechanism. Pure DP-MSC therapy may not be an effective treatment for rejection, although it may module immune tolerance in vivo.


Assuntos
Antígenos CD4/metabolismo , Polpa Dentária/citologia , Tolerância Imunológica , Interleucina-10/farmacologia , Subunidade alfa de Receptor de Interleucina-2/metabolismo , Células-Tronco Mesenquimais/imunologia , Linfócitos T Reguladores/imunologia , Fator de Crescimento Transformador beta1/farmacologia , Aloenxertos/imunologia , Animais , Biomarcadores/metabolismo , Proliferação de Células/efeitos dos fármacos , Técnicas de Cocultura , Fatores de Transcrição Forkhead/metabolismo , Sobrevivência de Enxerto/imunologia , Humanos , Tolerância Imunológica/efeitos dos fármacos , Teste de Cultura Mista de Linfócitos , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais/citologia , Camundongos Endogâmicos BALB C , Reação em Cadeia da Polimerase em Tempo Real , Transplante de Pele , Linfócitos T Reguladores/efeitos dos fármacos
5.
Arch Craniofac Surg ; 16(1): 11-16, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28913212

RESUMO

BACKGROUND: Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. METHODS: From 2013 through 2014, three calvarial defects were repaired using custommade 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. RESULTS: The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. CONCLUSION: An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.

6.
Aesthetic Plast Surg ; 29(6): 460-9; discussion 470-1, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16328645

RESUMO

Breast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated mass-like lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat-tail and tear drop signs were nonspecific signs for diagnosing the rupture of breast implant.


Assuntos
Implantes de Mama , Adulto , Feminino , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...