Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Microsc ; 277(2): 61-70, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31989597

RESUMO

The incudostapedial joint (ISJ) of the middle ear is important for proper transmission of sound energy to the cochlea. Recently, the biomechanics of the ISJ have been investigated using finite-element (FE) modelling, using simplified geometry. The objective of the present study was to investigate the feasibility of synchrotron-radiation phase-contrast imaging (SR-PCI) in visualising the ISJ ultrastructure. Three human cadaveric ISJs were dissected and scanned using SR-PCI at 0.9 µm isotropic voxel size. One of the samples was previously scanned at 9 µm voxel size. The images were visually compared and contrast-to-noise ratios (CNRs) were calculated (of both bone and soft tissues) for quantitative comparisons. The ISJ ultrastructure as well as adjacent bone and soft tissues were clearly visible in images with a 0.9 µm voxel size. The CNRs of the 0.9 µm images were relatively lower than those of the 9 µm scans, while the ratio of bone to soft tissue CNRs were higher, indicating better discernibility of bone from soft tissue in the 0.9 µm scans. This study was the first known attempt to image the ISJ ultrastructure using an SR-PCI scanner at submicron voxel size and results suggest that this method was successful. Future studies are needed to optimise the contrast and test the feasibility of imaging the ISJ in situ. LAY DESCRIPTION: The human middle ear consists of the eardrum, three small bones (the malleus, incus and stapes) and two joints connecting the bones (the incudostapedial joint and the incudomallear joint). The role of the middle ear is to amplify and transfer sound energy to the cochlea, the end organ of hearing. The incudostapedial joint (ISJ) of the middle ear is a synovial joint which is important for proper transmission of sound energy to the cochlea. Similar to other synovial joints it consists of meniscus, fluid and articulating surfaces. Recently, the biomechanics of the ISJ have been investigated using computational models, using grossly simplified geometry. Synchrotron radiation phase contrast imaging (SR-PCI) is a high-resolution imaging technique used to visualise small structures in three dimensions. The objective of the present study was to investigate the feasibility of using SR-PCI in visualising the ISJ ultrastructure. Three human cadaveric ISJs were dissected and scanned using SR-PCI at 0.9 µm isotropic voxel size. One of the samples was previously scanned at 9 µm voxel size. The images were both qualitatively and quantitatively compared. This study was the first known attempt to image the ISJ ultrastructure using an SR-PCI scanner at submicron voxel size and results suggest that this method was successful. Future studies are needed to optimise the contrast and feasibility of imaging the ISJ in situ.


Assuntos
Bigorna/diagnóstico por imagem , Articulações/diagnóstico por imagem , Estribo/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Bigorna/ultraestrutura , Articulações/ultraestrutura , Estribo/ultraestrutura , Síncrotrons
2.
J Biomed Phys Eng ; 9(1): 29-36, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30881932

RESUMO

BACKGROUND: Before treatment planning and dose delivery, quality assurance of multi-leaf collimator (MLC) has an important role in intensity-modulated radiation therapy (IMRT) due to the creation of multiple segments from optimization process. OBJECTIVE: The purpose of this study is to assess the quality control of MLC leaves using EBT3 Gafchromic films. MATERIAL AND METHODS: Leaf Position accuracy and leaf gap reproducibility were checked with Garden fence test. The garden fence test consists of 5 thin bands A) 0.2 Cm width spaced at 2 Cm intervals and B) 1 Cm width spaced at 1 Cm intervals. Each leaf accuracy was analyzed with measuring the full-width half-maximum (FWHM). Maximum and average leaf transmission were measured with gafchromic EBT3 films from Ashland for both 6 MV and 18 MV beams. RESULTS: Leaf positions were found to be in a range between 1.78 - 2.53 mm, instead of nominal 2 mm for the test A and between 9.09 - 10.36 mm, instead of nominal 10 mm for the test B. The Average radiation transmission of the MLC was noted 1.79% and 1.98% of the open 10x10 Cm2 field at isocenter for 6 MV and 18 MV beams, respectively. Maximum radiation transmission was noted 4.1% and 4.4% for 6 MV and 18 MV beams, respectively. CONCLUSION: In this study, application of gafchromic EBT3 films for the quality assurance of Euromechanics multileaf collimator was studied. Our results showed that the average leaf leakage and positional accuracy of this type of MLC were in the acceptance level based on the Protocols.

3.
J Microsc ; 265(3): 349-357, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27935035

RESUMO

High-resolution images of the cochlea are used to develop atlases to extract anatomical features from low-resolution clinical computed tomography (CT) images. We compare visualization and contrast of conventional absorption-based micro-CT to synchrotron radiation phase contrast imaging (SR-PCI) images of whole unstained, nondecalcified human cochleae. Three cadaveric cochleae were imaged using SR-PCI and micro-CT. Images were visually compared and contrast-to-noise ratios (CNRs) were computed from n = 27 regions-of-interest (enclosing soft tissue) for quantitative comparisons. Three-dimensional (3D) models of cochlear internal structures were constructed from SR-PCI images using a semiautomatic segmentation method. SR-PCI images provided superior visualization of soft tissue microstructures over conventional micro-CT images. CNR improved from 7.5 ± 2.5 in micro-CT images to 18.0 ± 4.3 in SR-PCI images (p < 0.0001). The semiautomatic segmentations yielded accurate reconstructions of 3D models of the intracochlear anatomy. The improved visualization, contrast and modelling achieved using SR-PCI images are very promising for developing atlas-based segmentation methods for postoperative evaluation of cochlear implant surgery.


Assuntos
Cóclea/diagnóstico por imagem , Imageamento Tridimensional/métodos , Radiografia/métodos , Cóclea/anatomia & histologia , Humanos
4.
J Microsc ; 264(3): 334-338, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27439684

RESUMO

High-resolution imaging of middle-ear geometry is necessary for finite-element modeling. Although micro-computed tomography (microCT) is widely used because of its ability to image bony structures of the middle ear, it is difficult to visualize soft tissues - including the tympanic membrane and the suspensory ligaments/tendons - because of lack of contrast. The objective of this research is to quantitatively evaluate the efficacy of iodine potassium iodide (IKI) solution as a contrast agent. Six human temporal bones were used in this experiment, which were obtained in right-left pairs, from three cadaveric heads. All bones were fixed using formaldehyde. Three bones (one from each pair) were stained in IKI solution for 2 days, whereas the other three were not stained. Samples were scanned using a microCT system at a resolution of 20 µm. Eight soft tissues in the middle ear were segmented: anterior mallear ligament, incudomallear joint, lateral mallear ligament, posterior incudal ligament, stapedial annular ligament, stapedius muscle, tympanic membrane and tensor tympani muscle. Contrast-to-noise ratios (CNRs) of each soft tissue were calculated for each temporal bone. Combined CNRs of the soft tissues in unstained samples were 6.1 ± 3.0, whereas they were 8.1 ± 2.7 in stained samples. Results from Welch's t-test indicate significant difference between the two groups at a 95% confidence interval. Results for paired t-tests for each of the individual soft tissues also indicated significant improvement of contrast in all tissues after staining. Relatively large soft tissues in the middle ear such as the tympanic membrane and the tensor tympani muscle were impacted by staining more than smaller tissues such as the stapedial annular ligament. The increase in contrast with IKI solution confirms its potential application in automatic segmentation of the middle-ear soft tissues.


Assuntos
Meios de Contraste , Orelha Média/diagnóstico por imagem , Compostos de Iodo , Microtomografia por Raio-X/métodos , Adulto , Humanos , Intensificação de Imagem Radiográfica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...