Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Rev Sci Instrum ; 95(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38206100

RESUMO

The imaging heavy ion beam probe (i-HIBP) diagnostic has been successfully commissioned at ASDEX Upgrade. The i-HIBP injects a primary neutral beam into the plasma, where it is ionized, leading to a fan of secondary (charged) beams. These are deflected by the magnetic field of the tokamak and collected by a scintillator detector, generating a strike-line light pattern that encodes information on the density, electrostatic potential, and magnetic field of the plasma edge. The first measurements have been made, demonstrating the proof-of-principle of this diagnostic technique. A primary beam of 85/87Rb has been used with energies ranging between 60 and 72 keV and extracted currents up to 1.5 mA. The first signals have been obtained in experiments covering a wide range of parameter spaces, with plasma currents (Ip) between 0.2 and 0.8 MA and on-axis toroidal magnetic field (Bt) between 1.9 and 2.7 T. Low densities appear to be critical for the performance of the diagnostic, as signals are typically observed only when the line integrated density is below 2.0-3.0 × 1019 m-2 in the central interferometer chord, depending on the plasma shape. The strike line moves as expected when Ip is ramped, indicating that current measurements are possible. Additionally, clear dynamics in the intensity of the strike line are often observed, which might be linked to changes in the edge profile structure. However, the signal-to-background ratio of the signals is hampered by stray light, and the image guide degradation is due to neutron irradiation. Finally, simulations have been carried out to investigate the sensitivity of the expected signals to plasma density and temperature. The results are in qualitative agreement with the experimental observations, suggesting that the diagnostic is almost insensitive to fluctuations in the temperature profile, while the signal level is highly determined by the density profile due to the beam attenuation.

2.
Rev Sci Instrum ; 94(4)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38081276

RESUMO

A new shattered pellet injection system was designed and built to perform disruption mitigation experiments on ASDEX Upgrade. The system can inject pellets with diameters of 1, 2, 4, or 8 mm with variable lengths over a range of L/D ratios of ∼0.5-1.5. By using helium or deuterium as propellant gas, the pellets can be accelerated to speeds between 60 and 750 m/s. The velocity range slightly depends on the pellet mass. The injection system is capable of preparing three pellets in separate barrels at the same time. Once accelerated by the propellant gas pulse, the pellets travel through one of three parallel flight tubes. Each flight tube is separated into three sections with increasing diameters of 12, 14, and 16 mm. Two gaps between the sections allow for removal of the propellant gas by expansion into two separate expansions tanks (0.3 and 0.035 m3), pellet observation in the first gap and the torus gate valve in the second. Each flight tube end is equipped with an exchangeable shatter head with different shatter angles, square or circular cross-section, and different lengths. The gas preparation and control systems allow highly automated pellet generation for precision of the pellet composition and an excellent reproducibility of shattered pellet experiments.

3.
Acta Neurochir (Wien) ; 165(7): 1881-1889, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178247

RESUMO

BACKGROUND: Since its approval by the US Food and Drug Administration (FDA) in 2018, the flow disruptor Woven EndoBridge (WEB) device has become increasingly popular for the endovascular treatment of unruptured and ruptured cerebral aneurysms. However, the occlusion rates seem rather low and the retreatment rates rather high compared to other treatment methods. For initially ruptured aneurysms, a retreatment rate of 13 % has been reported. A variety of retreatment strategies has been proposed; however, there is a paucity of data concerning microsurgical clipping of WEB-pretreated aneurysms, especially previously ruptured ones. Thus, we present a single-center series of five ruptured aneurysms treated with the WEB device and retreated with microsurgical clipping. METHODS: A retrospective study including all patients presenting with a ruptured aneurysm undergoing WEB treatment at our institution between 2019 and 2021 was performed. Subsequently, all patients with an aneurysm remnant or recurrence of the target aneurysm retreated with microsurgical clipping were identified. RESULTS: Overall, five patients with a ruptured aneurysm treated with WEB and retreated with microsurgical clipping were included. Besides one basilar apex aneurysm, all aneurysms were located at the anterior communicating artery (AComA) complex. All aneurysms were wide-necked with a mean dome-to-neck ratio of 1.5. Clipping was feasible and safe in all aneurysms, and complete occlusion was achieved in 4 of 5 aneurysms. CONCLUSIONS: Microsurgical clipping for initially ruptured WEB-treated aneurysms is a feasible, safe, and effective treatment method in well-selected patients.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Resultado do Tratamento , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Retratamento
4.
Clin Neurol Neurosurg ; 212: 107089, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34902753

RESUMO

OBJECTIVE: Traumatic brain injury (TBI) constitutes a major cause of trauma-related disability and mortality. The epidemiology and implications of associated cranial nerve injuries (CNI) in moderate to severe TBI are largely unknown. We aimed to determine the incidence of CNI in a large European cohort of TBI patients as well as clinical differences between TBI cases with and without concomitant CNI (CNI vs. control group) by means of a multinational trauma registry. METHODS: The TraumaRegister DGU® was evaluated for trauma patients with head injuries ≥ 2 Abbreviated Injury Scale, who had to be treated on intensive care units after emergency admission to European hospitals between 2008 and 2017. CNI and control cases were compared with respect to demographic, clinical, and outcome variables. RESULTS: 1.0% (946 of 91,196) of TBI patients presented with additional CNI. On average, CNI patients were younger than control cases (44.3 ± 20.6 vs. 51.8 ± 23.0 years) but did not differ regarding sex distribution (CNI 69.4% males vs. control 69.1%). Traffic accidents were encountered more frequently in CNI cases (52.3% vs. 46.7%; p < 0.001; chi-squared test) and falls more commonly in the control group (45.2% vs. 37.1%; p < 0.001). CNI patients suffered more frequently from concomitant face injuries (28.2% vs. 17.5%; p < 0.001) and skull base fractures (51.0% vs. 23.5%; p < 0.001). Despite similar mean Injury Severity Score (CNI 21.8 ± 11.3; control 21.1 ± 11.7) and Glasgow Coma Scale score (CNI 10.9 ± 4.2, control 11.1 ± 4.4), there was a considerably higher proportion of anisocoria in CNI patients (20.1% vs. 11.2%; p < 0.001). Following primary treatment, 50.8% of CNI and 35.5% of control cases showed moderate to severe disability (Glasgow Outcome Scale score 3-4; p < 0.001). CONCLUSION: CNI rarely occur in the context of TBI. When present, they indicate a higher likelihood of functional impairment following primary care and complicating skull base fractures should be suspected.


Assuntos
Lesões Encefálicas Traumáticas/epidemiologia , Traumatismos dos Nervos Cranianos/epidemiologia , Sistema de Registros/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Comorbidade , Europa (Continente)/epidemiologia , Feminino , Humanos , Incidência , Lactente , Masculino , Pessoa de Meia-Idade , Índices de Gravidade do Trauma , Adulto Jovem
5.
AJNR Am J Neuroradiol ; 42(11): 1956-1961, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34556476

RESUMO

BACKGROUND AND PURPOSE: The acute phase of aneurysmal SAH is characterized by a plethora of impending complications with the potential to worsen patients' outcomes. The aim of this study was to evaluate whether an elaborated CTP-based imaging protocol during the acute aneurysmal SAH phase is able to prevent delayed infarctions and contribute to a better outcome. MATERIALS AND METHODS: In 2012, an elaborated CTP-based protocol was implemented for the management of patients with aneurysmal SAH. Retrospective analysis of patients with aneurysmal SAH treated from 2010 to 2013 was performed, comparing the patients treated before (group one, 2010-2011) with those treated after the protocol implementation (group two, 2012-2013) with regard to delayed infarctions and outcome according to the mRS at 3-months' follow-up. RESULTS: A total of 133 patients were enrolled, of whom 57 were included in group 1, and 76, in group 2. There were no significant differences between the groups concerning baseline characteristics. In the multivariate analysis, independent predictors of a good outcome (mRS ≤ 2) were younger age (P < .001), lower World Federation of Neurosurgical Societies grade (P < .001), absence of delayed infarction (P = .01), and management according to the CTP protocol (P = .01). Larger or multiple infarctions occurred significantly more often in group 1 compared with group 2 (88% versus 33% of all delayed infarctions, P = .03). The outcome in group 2 was significantly better compared with group 1 (P = .005). CONCLUSIONS: The findings suggest that implementation of an elaborated CTP protocol is associated with a better outcome. An earlier initiation of further diagnostics and treatment with prevention of large territorial and/or multiple infarctions might have led to this finding.


Assuntos
Hemorragia Subaracnóidea , Humanos , Perfusão , Estudos Retrospectivos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/terapia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Neurosurg Rev ; 44(6): 3421-3425, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33674981

RESUMO

Hygiene measures were intensified when the COVID-19 pandemic began. Patient contacts were limited to a minimum. Visitors were either not allowed for a certain period or limited for the rest of the time. The hospital staff began to wear masks and gloves continuously. Clinical examinations and routine wound controls were also performed under intensified hygiene standards. These circumstances result in a limitation of direct physical interactions between the nursing staff, the physicians and the patients. We analyzed to what extent the intensification of hygiene measures affects the rate of surgical site infections (SSI) after neurosurgical procedures. The rate of SSI during the 6-month interval after the beginning of COVID-19 measures was compared with the SSI rate before. The numbers of the period before COVID-19 were analyzed as mean values resulting from the analysis of two separate time periods each consisting of 6 months. The spectrum of surgical procedures was compared. Patient-related risk factors for SSIs were noted. Microorganisms were analyzed. We focused on SSIs occurring at a maximum of 60 days after the primary surgery. Overall, in the two respective 6-month periods before COVID-19, a mean of 1379 patients was surgically treated in our institution. After the beginning of COVID-19 (starting from 04/2020) our surgical numbers dropped by 101, resulting in a total number of 1278 patients being operated after 03/2020 until 09/2020. The SSI rate was 3.6% (03/2019-09/2019, 50 SSIs) and 2.2% (09/2019-03/2020, 29 SSIs), resulting in a mean of 2.9% before COVID-19 began. After the beginning of COVID-19 hygiene measures, this rate dropped to 1.4% (16 SSIs) resembling a significant reduction (p=0.003). Risk factors for the development of SSI were present in 81.3% of all patients. Pre- and post-COVID-19 patient groups had similar baseline characteristics. The same holds true when comparing the percentage of cranial and spinal procedures pre- and post-COVID-19 (p=0.91). Comparing the numbers (p=0.28) and the species (p=0.85) of microorganisms (MO) causing SSI, we found a similar distribution. Despite equal demographics and characteristics of SSI, the rate of SSI dropped substantially. This argues for an effective reduction of postoperative SSI resulting from the implementation of strict hygiene measures being established after the beginning of the COVID-19 pandemic. We therefore advocate continuing with strict and intensive hygiene measures in the future.


Assuntos
COVID-19 , Neurocirurgia , Humanos , Procedimentos Neurocirúrgicos/efeitos adversos , Pandemias , Fatores de Risco , SARS-CoV-2 , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
7.
Acta Neurochir (Wien) ; 162(10): 2421-2430, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32779025

RESUMO

OBJECTIVE: Adjustable differential pressure (DP) valves in combination with fixed anti-siphon devices are currently a popular combination in counteracting the effects of cerebrospinal fluid overdrainage following implantation of a ventriculoperitoneal shunt system. The study examined the flow performance of three DP valves in successive combination with an anti-siphon device in an in vitro shunt laboratory with and without vertical motion. METHODS: We analyzed three DP valves (Codman Hakim Medos programmable valve [HM], Codman CertasPlus [CP], and Miethke proGAV [PG], in combination with either Codman SiphonGuard [SG] or Miethke ShuntAssistant [SA]), resulting in the evaluation of six different valve combinations. Defined DP conditions between 4 and 40 cm H2O within a simulated shunt system were generated and the specific flow characteristics were measured. In addition, combinations with SA, which is a gravity-dependent valve, were measured in defined spatial positions (90°, 60°). All device combinations were tested during vertical motion with movement frequencies of 2, 3, and 4 Hz. RESULTS: All valve combinations effectively counteracted the siphon effect in relation to the chosen DP. Angulation-related flow changes were similar in the three combinations of DP valve and SA in the 60° and 90° position. In CP-SA and PG-SA, repeated vertical movement at 2, 3, and 4 Hz led to significant increase in flow, whereas in HM-SA, constant increase was seen at 4 Hz only (flow change at 4Hz, DP 40 cm H2O: PG (opening pressure 4 cm H2O) 90°: 0.95 ml/min, 60°: 0.71 ml/min; HM (opening pressure 4 cm H2O) 90°: 0.66 ml/min, 60°: 0.41 ml/min; CP (PL 2) 90°: 0.94 ml/min, 60°: 0.79 ml/min; p < 0.01); however, HM-SA showed relevant motion-induced flow already at low DPs (0.85 ml/min, DP 4 cm H2O). In combinations of DP valve with SG, increase of flow was far less pronounced and even led to significant reduction of flow in certain constellations. Maximum overall flow increase was 0.46 ± 0.04 ml/min with a HM (opening pressure 12 cm H2O) at 2 Hz and a DP of 10 cm H2O, whereas maximum flow decrease was 1.12 ± 0.08 with a PG (opening pressure 4 cm H2O) at 3 Hz and a DP of 10 cmH2O. CONCLUSION: In an experimental setup, all valve combinations effectively counteracted the siphon effect in the vertical position according to their added resistance. Motion-induced increased flow was consistently demonstrated in combinations of DP valve and SA. The combination of HM and SA especially showed relevant motion-induced flow already at low DPs. In combinations of DP and SG, the pattern of the motion induced flow was more inconsistent and motion even led to significant flow reduction, predominantly at DPs of 10 and 20 cmH2O.


Assuntos
Hidrocefalia/cirurgia , Derivação Ventriculoperitoneal/instrumentação , Gravitação , Humanos , Movimento (Física) , Próteses e Implantes/efeitos adversos , Próteses e Implantes/normas
8.
Acta Neurochir (Wien) ; 162(5): 1033-1040, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31997071

RESUMO

BACKGROUND: Programmable differential pressure (DP) valves combined with an anti-siphon device (ASD) represent the current standard of care in preemtping overdrainage associated with ventriculoperitoneal shunting for hydrocephalus. OBJECTIVE: We aimed to provide comparative data of four combinations of two ASDs of different working principles in combination with two DP valves in an in vitro model in order to achieve a better understanding of the flow characteristics and potential clinical application. METHODS: We analyzed the flow performance of four possible combinations of two DP valves (CHPV [HM]; proGAV 2.0[PG]) in combination with either a gravity-regulated (Shuntassistant [SA]) or a flow-regulated (SiphonGuard [SG]) ASD in an in vitro setup. A DP between 4 and 60 cmH2O was generated, and the specific flow characteristics were measured. In addition, the two combinations with gravity-regulated ASDs were measured in defined spatial positions. RESULTS: Flow characteristics of the SA combinations corresponded to the DP in linear fashion and to the spatial position. Flow characteristics of the SG combinations were dependent upon the DP in a non-linear fashion and independent of the spatial position. Highest mean flow rate of the PG-SG- (HM-SG-) combination was 1.41 ± 0.24 ml/min (1.16 ± 0.06 ml/min). The mean flow rates sharply decreased with increasing inflow pressure and subsequently increased slowly up to 0.82 ± 0.26 ml/min (0.77 ± 0.08 ml/min). CONCLUSION: All tested device combinations were able to control hydrostatic effect and prevent consecutive excessive flow, to varying degrees. However, significant differences in flow characteristics can be seen, which might be relevant for their clinical application.


Assuntos
Derivações do Líquido Cefalorraquidiano/instrumentação , Desenho de Equipamento , Hidrocefalia/cirurgia , Teste de Materiais , Derivações do Líquido Cefalorraquidiano/efeitos adversos , Gravitação , Humanos
9.
Neurosurg Rev ; 43(1): 273-279, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30426355

RESUMO

Unresectable malignant intramedullary tumors and metastases usually require radiotherapy which intensifies spinal cord edema and might result in neurological decline. Spinal expansion duroplasty before radiotherapy enlarges the intrathecal volume and might thus prevent neurological deficits. The study aims to evaluate the clinical course of patients undergoing expansion duroplasty. This retrospective analysis (2007-2016) included all patients with unresectable intramedullary tumors who underwent spinal expansion duroplasty. To assess the degree of preoperative cord enlargement, we calculated the "diameter ratio": diameter of the spinal cord below and above the tumor / diameter of the tumor × 2. The presence of perimedullary cerebrospinal fluid (CSF) at the affected levels was analyzed on the preoperative magnetic resonance imaging (MRI). We recorded the occurrence of neurological deficits, wound breakdown, and CSF fistula. We screened 985 patients, 11 of which were included. Eight patients had an intramedullary metastasis, three patients a spinal malignant glioma. A diameter ratio ≤ 0.8 representing a significant preoperative intramedullary enlargement was seen in 10 cases (90.9%). Postoperative imaging was available in 9 patients, demonstrating successful decompression in 8 of the 9 patients (88.9%). The postoperative course was uneventful in 9 patients (81.8%). Mean overall survival was 13.4 (SD 16.2) months. Spinal expansion duroplasty prior to radiotherapy is a previously undescribed concept. Despite neoadjuvant radiation, no wound breakdown or CSF fistula occurred. In unresectable intramedullary tumors and metastases, spinal expansion duroplasty seems to be a safe procedure with the potential to prevent neurological decline due to radiation-induced cord swelling.


Assuntos
Descompressão Cirúrgica , Edema/cirurgia , Glioma/cirurgia , Procedimentos Neurocirúrgicos/métodos , Neoplasias da Medula Espinal/cirurgia , Adulto , Edema/etiologia , Feminino , Glioma/diagnóstico por imagem , Glioma/patologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias da Medula Espinal/diagnóstico por imagem , Neoplasias da Medula Espinal/patologia
11.
J Neurol Surg A Cent Eur Neurosurg ; 80(3): 220-222, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30708389

RESUMO

BACKGROUND: Paraplegia due to spinal combined subdural/subarachnoid hemorrhage is an extremely rare complication following percutaneous spinal augmentation procedures. METHODS: A 63-year-old male patient presented with severe neurologic decline (paraplegia with sensory and autonomic dysfunction) resulting from a multilevel spinal subarachnoid hemorrhage shortly after bilateral kyphoplasty. RESULTS: Reduction of intrathecal pressure via multiple dural and arachnoidal incisions and removal of the hematoma resulted in a good neurologic recovery with surgical decompression even though evacuation was performed with a significant delay after the onset of neurologic worsening. CONCLUSION: Spinal augmentation procedures should only be performed in a setting where management of complications can also be diagnosed and performed. Robot-assisted or navigation-assisted pedicle perforation should be considered because complications can be reduced significantly.


Assuntos
Descompressão Cirúrgica/métodos , Hematoma Subdural/etiologia , Cifoplastia/efeitos adversos , Procedimentos Neurocirúrgicos/métodos , Paraplegia/etiologia , Hemorragia Subaracnóidea/etiologia , Hematoma Subdural/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Paraplegia/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Hemorragia Subaracnóidea/cirurgia , Resultado do Tratamento
12.
Rev Sci Instrum ; 89(10): 10D102, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399953

RESUMO

The thermal helium beam edge diagnostic has recently been upgraded at the ASDEX Upgrade (AUG) tokamak experiment. Line ratio spectroscopy on neutral helium is a valuable tool for simultaneous determination of the electron temperature and density of plasmas. The diagnostic now offers a temporal resolution of 900 kHz with a spatial resolution of up to 3 mm at 32 lines of sight (LOS) simultaneously. The LOS covers a radial region of 8.5 cm, starting at the limiter radius and reaching into the confined region beyond the separatrix. Two components are of particular importance for the aforementioned hardware improvements. The first is the optical head, which collects the light from the experiment. Equipped with an innovative clamping system for optical fiber ends, an arbitrary distribution pattern of LOS can be achieved to gain radial and poloidal profiles. The second major development is a new polychromator system that measures the intensity of the 587 nm, 667 nm, 706 nm, and 728 nm helium lines simultaneously for 32 channels with filter-photomultiplier tube arrays. Thus, the thermal helium beam diagnostic supplements the AUG edge diagnostics, offering fast and spatially highly resolved electron temperature and density profile measurements that cover the plasma edge and scrape-off layer region. Plasma fluctuations, edge localized modes, filaments, and other turbulent structures are resolved, allowing analysis of their frequency and localization or their propagation velocity.

14.
Nervenarzt ; 89(6): 648-657, 2018 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-29679126

RESUMO

BACKGROUND: Adult spinal deformity (ASD) is mostly a progressive disease which usually leads to chronic pain. Due to increased prevalence in older people many patients suffer from comorbidities, which make conservative and surgical treatment even more complex. OBJECTIVE: This article provides an overview on the current conservative and surgical treatment options. MATERIAL AND METHODS: An extensive literature search was carried out via Medline plus an additional evaluation of the authors' personal experiences was performed. RESULTS: The current conservative and surgical treatments are outlined and potential risk factors and predictors which may lead to inferior clinical outcome are discussed. CONCLUSION: Patients for whom even conservative treatment leads to success should be identified earlier and better. The surgical treatment ranges from minimally invasive decompression to multilevel fusions. Complications in large corrective interventions can be substantial but if the indications are correctly assessed, such complex surgical treatment has excellent clinical results in terms of pain and quality of life.


Assuntos
Procedimentos Neurocirúrgicos , Doenças da Coluna Vertebral , Descompressão Cirúrgica , Humanos , Dor , Qualidade de Vida , Doenças da Coluna Vertebral/cirurgia , Resultado do Tratamento
15.
Nervenarzt ; 89(6): 639-647, 2018 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-29679129

RESUMO

BACKGROUND: Degenerative diseases of the lumbar spine and associated lower back pain represent a major epidemiological and health-related economic challenge. A distinction is made between specific and unspecific lower back pain. In specific lower back pain lumbar disc herniation and spinal canal stenosis with or without associated segment instability are among the most frequent pathologies. Diverse conservative and operative strategies for treatment of these diseases are available. OBJECTIVES: The aim of this article is to present an overview of current data and an evidence-based assessment of the possible forms of treatment. MATERIAL AND METHODS: An extensive literature search was carried out via Medline plus an additional evaluation of the authors' personal experiences. RESULTS: Conservative and surgical treatment represent efficient treatment options for degenerative diseases of the lumbar spine. Surgical treatment of lumbar disc herniation shows slight advantages compared to conservative treatment consisting of faster recovery of neurological deficits and a faster restitution of pain control. Surgical decompression is superior to conservative measures for the treatment of spinal canal stenosis and degenerative spondylolisthesis. In this scenario conservative treatment represents an important supporting measure for surgical treatment in order to improve the mobility of patients and the outcome of surgical treatment. CONCLUSION: The treatment of specific lower back pain due to degenerative lumbar pathologies represents an interdisciplinary challenge, requiring both conservative and surgical treatment strategies in a synergistic treatment concept in order to achieve the best results for patients.


Assuntos
Vértebras Lombares , Doenças da Coluna Vertebral , Humanos , Degeneração do Disco Intervertebral/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Vértebras Lombares/cirurgia , Doenças da Coluna Vertebral/patologia , Doenças da Coluna Vertebral/cirurgia , Estenose Espinal/cirurgia , Espondilolistese
16.
J Appl Physiol (1985) ; 124(1): 118-130, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28860177

RESUMO

Estrogen deficiency and aging are associated with osteoporosis, impaired bone healing, and lower cognitive performance. Close functional and physical connections occur between bone and the central nervous system. An anti-inflammatory drug, zileuton (which is an inhibitor of arachidonate 5-lipoxygenase), is known to have a positive effect on bone tissue repair and brain ischemia. We studied the effect of zileuton on osteopenic bone and its healing and on the genes considered to be crucial for the cross talks between bone and brain. Three-month-old Sprague-Dawley rats were ovariectomized or left untreated. After 8 wk, bilateral metaphyseal tibia osteotomy with plate osteosynthesis was performed in all rats. Ovariectomized rats were fed with food containing zileuton (1, 10, or 100 mg/kg body wt) for 5 wk. In tibiae, bone volume, callus and cortical volume, and gene expression of osteocalcin and alkaline phosphatase were enhanced by zileuton (10 or 100 mg); biomechanical properties and bone density were not changed. In femur, zileuton enlarged cortical volume distal and trabecular volume proximal, decreasing their density. The expression level of brain Sema3a, known to regulate bone mass positively, was downregulated after ovariectomy. In contrast, bone Sema4d, a negative regulator of bone mass, was upregulated in the tibia callus after ovariectomy, whereas zileuton treatment (10 or 100 mg) resulted in reverse effects. Here, we describe for the first time the expression of Rbbp4 mRNA and its increase in tibia after ovariectomy. Zileuton caused downregulation of Rbbp4 in the hippocampus and had an effect on bone healing, changed the expression of genes involved in cross talk between bones and brain, and may be a potent drug for further examination in estrogen deficiency-related dysfunction(s). NEW & NOTEWORTHY Zileuton, a 5-lipoxygenase inhibitor, increased bone volume, callus and cortical volume in osteotomized tibia, and trabecular and cortical volume in femur. Although the expression of Sema3a (positively regulating bone mass) in brain was downregulated and Sema4d (negatively regulating bone mass) was upregulated in tibia callus after ovariectomy, zileuton could counteract these effects. Rbbp4 (involved in age-related memory loss) was increased in tibia callus after ovariectomy.


Assuntos
Encéfalo/efeitos dos fármacos , Hidroxiureia/análogos & derivados , Inibidores de Lipoxigenase/uso terapêutico , Osteoporose/tratamento farmacológico , Tíbia/efeitos dos fármacos , Animais , Encéfalo/metabolismo , Avaliação Pré-Clínica de Medicamentos , Feminino , Hidroxiureia/farmacologia , Hidroxiureia/uso terapêutico , Inibidores de Lipoxigenase/farmacologia , Ovariectomia , Ratos Sprague-Dawley , Tíbia/metabolismo , Microtomografia por Raio-X
17.
BMC Urol ; 17(1): 46, 2017 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-28629351

RESUMO

BACKGROUND: Urological diseases and their treatment may negatively influence continence, potency, and health-related quality of life (HRQOL). Although current guidelines recommend HRQOL assessment in clinical urology, specific guidance on how to assess HRQOL is frequently absent. We evaluated whether and how urologists assess HRQOL and how they determine its practicality. METHODS: A random sample of 4500 (from 5200 identified German urologists) was drawn and invited to participate in a postal survey (an initial letter followed by one reminder after six weeks). The questionnaire included questions on whether and how HRQOL is assessed, general attitudes towards the concept of HRQOL, and socio-demographics. Due to the exploratory character of the study we produced mainly descriptive statistics. Chi2-tests and logistic regression were used for subgroup-analysis. RESULTS: 1557 urologists (85% male, with a mean age of 49 yrs.) participated. Most of them (87%) considered HRQOL assessment as 'important' in daily work, while only 7% reported not assessing HRQOL. Patients with prostate carcinoma, incontinence, pain, and benign prostate hyperplasia were the main target groups for HRQOL assessment. The primary aim of HRQOL assessment was to support treatment decisions, monitor patients, and produce a 'baseline measurement'. Two-thirds of urologists used questionnaires and interviews to evaluate HRQOL and one-quarter assessed HRQOL by asking: 'How are you?'. The main barriers to HRQOL assessment were anticipated questionnaire costs (77%), extensive questionnaire length (52%), and complex analysis (51%). CONCLUSIONS: The majority of German urologists assess HRQOL as part of their clinical routine. However, knowledge of HRQOL assessment, analysis, and interpretation seems to be limited in this group. Therefore, urologists may benefit from a targeted education program. TRIAL REGISTRATION: The clinical trial was registered with the code VfD_13_003629 at the German Healthcare Research Registry ( www.versorgungsforschung-deutschland.de ).


Assuntos
Qualidade de Vida/psicologia , Doenças Urológicas/psicologia , Urologistas/psicologia , Urologia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais/métodos , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Urológicas/diagnóstico , Doenças Urológicas/epidemiologia
18.
Acta Neurochir (Wien) ; 159(7): 1321-1324, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28516363

RESUMO

Posterior reversible encephalopathy syndrome (PRES) is thought to result from endothelial dysfunction and breakdown of the blood-brain barrier with subsequent vasogenic edema. Abrupt hypertension has been identified as one of its risk factors. We present a rare case of PRES in the anterior circulation with sudden onset of left hemiparesis and rapid neurological deterioration on the basis of hypertensive crisis. Due to refractory intracranial hypertension, the patient required emergent right decompressive craniectomy. Further investigations, including a biopsy, revealed an atypical form of PRES. This case illustrates the importance of aggressive medical and early surgical management to prevent permanent neurological deficits.


Assuntos
Descompressão Cirúrgica/efeitos adversos , Pressão Intracraniana , Síndrome da Leucoencefalopatia Posterior/diagnóstico , Adulto , Barreira Hematoencefálica/patologia , Feminino , Humanos , Síndrome da Leucoencefalopatia Posterior/cirurgia , Complicações Pós-Operatórias , Fatores de Risco
19.
Rev Sci Instrum ; 88(3): 033509, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372367

RESUMO

In magnetically confined fusion plasmas controlled gas injection is crucial for plasma fuelling as well as for various diagnostic applications such as active spectroscopy. We present a new, versatile system for the injection of collimated thermal gas beams into a vacuum chamber. This system consists of a gas pressure chamber, sealed by a custom made piezo valve towards a small capillary for gas injection. The setup can directly be placed inside of the vacuum chamber of fusion devices as it is small and immune against high magnetic fields. This enables gas injection close to the plasma periphery with high duty cycles and fast switch on/off times ≲ 0.5 ms. In this work, we present the design details of this new injection system and a systematic characterization of the beam properties as well as the gas flowrates which can be accomplished. The thin and relatively short capillary yields a small divergence of the injected beam with a half opening angle of 20°. The gas box is designed for pre-fill pressures of 10 mbar up to 100 bars and makes a flowrate accessible from 1018 part/s up to 1023 part/s. It hence is a versatile system for both diagnostic as well as fuelling applications. The implementation of this system in ASDEX Upgrade will be described and its application for line ratio spectroscopy on helium will be demonstrated on a selected example.

20.
Rev Sci Instrum ; 88(3): 033508, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28372397

RESUMO

A new high speed gas valve was developed for disruption mitigation studies in the tokamak ASDEX Upgrade. The valve was designed to operate inside the vacuum vessel to reduce the time of flight of the injected gas and to prevent dispersion of the gas cloud before the gas reaches the plasma. A spring-driven mechanism was chosen for the valve as it is robust against the high magnetic fields and electromagnetic disturbances inside the vessel. The internal gas reservoir (128 cm3) of the valve, which holds the mitigation gas, is opened within 1.5 ms, and the maximal stroke between the valve plate and nozzle (diameter 13 mm) is 4.5 mm. This allows a peak flow rate of 72 kPam3/s after 1 ms which was determined both analytically and numerically. The highest gas velocity (approximately 560 m/s) is reached 0.6 ms after the valve is opened. The gas cloud expands in a pear shape with an opening angle of 49°.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...