Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ophthalmologie ; 119(8): 807-812, 2022 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-35089415

RESUMO

BACKGROUND: There are only few reports on ocular symptoms and manifestations in association with coronavirus disease 2019 (COVID-19). OBJECTIVE: The aim of this study is to describe ocular manifestations in the anterior and posterior segments of the eye and to analyze viral prevalence in tears of patients with COVID-19. METHODS: Hospitalized COVID-19 patients treated from 16 April 2020 to 7 January 2021 at this hospital were screened for ocular manifestations in the anterior and posterior segments. Conjunctival swabs were analyzed for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA. RESULTS: A total of 37 patients were enrolled in this study. In the anterior segment we found chemosis of the conjunctiva (5), hyposphagma (2) and conjunctivitis (1). In 11 patients vascular alterations and potentially disease-specific manifestations of the fundus were found in one or both eyes: retinal hemorrhages (5), cotton wool spots (5) and tortuosity (5). One patient demonstrated branch artery occlusion, one had branch retinal vein occlusion and two patients had positive conjunctival swab results in one or both eyes. CONCLUSION: Our findings of the anterior segment are commonly known, although not specific for COVID-19. Various vascular fundus abnormalities were found in the study; however, it is unclear whether these were correlated to systemic comorbidities or whether they were caused or exacerbated by COVID-19. This study suggests that the risk of viral transmission via tears is low.


Assuntos
COVID-19 , COVID-19/epidemiologia , Túnica Conjuntiva , Humanos , RNA Viral , SARS-CoV-2 , Lágrimas
4.
Minerva Anestesiol ; 84(7): 820-828, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29027777

RESUMO

BACKGROUND: For intraocular surgery, most authors recommend general anesthesia including intubation and neuromuscular blockade to avoid complications by patient movements. However, anesthesia using a laryngeal mask and avoidance of muscle relaxants is common clinical practice. Purpose of this prospective observational study was to compare the incidence of eye movement and deviation of the eye axis during general anesthesia adjusted to minimal alveolar concentration (MAC) for pars plana-vitrectomy (PPV) using a laryngeal mask without neuromuscular blockade (LM) versus endotracheal intubation and neuromuscular blockade (INT). METHODS: The patients (N.=148) who underwent PPV for vitreoretinal disorders received MAC adjusted general anesthesia by volatile anesthetics. Seventy-four patients were subjected to LM and 74 to INT. In both groups the patient's lungs were mechanically ventilated without allowing spontaneous ventilation. Eye movements and upward deviations were judged and documented during surgery. Postoperatively quality of immobilization was assessed by a standardized questionnaire. RESULTS: Intraoperative movements were not observed in either group. Upward eye deviation was observed in nine (12%) patients in the LM group, but not in patients in the INT group (0%; P=0.003). The standardized questionnaire revealed no clinically relevant difference in quality of immobilization between groups, especially eye deviations did not lead to any relevant surgical complications or difficulties. CONCLUSIONS: For PPV, MAC adjusted balanced anesthesia using a laryngeal mask without neuromuscular blockade was associated with more, but clinically irrelevant upward eye deviations and may be an alternative to intubation with neuromuscular blockade. However, adequate depth of anesthesia must be assured to avoid unwanted injuries during surgery.


Assuntos
Anestesia/métodos , Imobilização/métodos , Intubação Intratraqueal , Máscaras Laríngeas , Bloqueio Neuromuscular , Vitrectomia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Acta Ophthalmol ; 88(8): 885-90, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19548881

RESUMO

PURPOSE: Prior to phakic intraocular lens implantation, it is important to obtain precise knowledge of the anterior chamber depth (ACD). Accurate topographic evaluation of the iridocorneal angle is helpful in estimating risk for angle-closure glaucoma. This study investigated the use of the Orbscan II system to measure ACD and the iridocorneal angle in healthy subjects and assessed the influences of age, gender and spherical equivalent on these parameters. METHODS: The Orbscan II system was used to determine the ACD and iridocorneal angle in eight different positions in 390 healthy White subjects with a mean age of 41± 16years (range 10-80 years). The sample included 242 male and 148 female subjects. The influences of age, gender and spherical equivalent were assessed using multiple regression analysis. RESULTS: Mean ACD was 2.87 ± 0.04 mm in male subjects and 2.81±0.37mm in female subjects. The explanatory variables relevant to the ACD were age (partial regression coefficient B = -0.0115, p < 0.0001), spherical equivalent (B = - 0.0562, p< 0.0001) and gender (B = 0.0996, p=0.0036). The mean iridocorneal angle (MIA) was 30.7 ± 2.0 ° in male and 31.6 ± 2.1° in female subjects. The variables relevant to the MIA were gender (B =- 0.865, p < 0.0001), age (B =- 0.017, p = 0.0007) and spherical equivalent (B = - 0.121, p = 0.001). The superior iridocorneal angle displayed the strongest negative correlation with age, whereas the temporal angle exhibited the least correlation with age. CONCLUSIONS: The decline in ACD appears to be linear with age, amounting to a mean of 0.58 mm over 50 years. This may become clinically relevant in the use of phakic intraocular lenses. In addition, the angle is more severely constricted in the superior quadrant than in the temporal quadrant.


Assuntos
Envelhecimento/fisiologia , Câmara Anterior/anatomia & histologia , Córnea/anatomia & histologia , Iris/anatomia & histologia , Refração Ocular/fisiologia , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biometria , Criança , Feminino , Humanos , Masculino , Microscopia Acústica , Pessoa de Meia-Idade , Lentes Intraoculares Fácicas , Fatores Sexuais , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...