Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38793882

RESUMO

In this work, we experimentally analyzed and demonstrated the performance of an in-line Mach-Zehnder interferometer in the visible region, with an LED light source. The different waist diameter taper and asymmetric core-offset interferometers proposed used a single-mode fiber (SMF). The visibility achieved was V = 0.14 with an FSR of 23 nm for the taper MZI structure and visibilities of V = 0.3, V = 0.27, and V = 0.34 with FSRs of 23 nm, 17 nm, and 8 nm and separation lengths L of 2.5 cm, 4.0 cm, and 5.0 cm between the core-offset structure, respectively. The experimental investigation of the response to the temperature sensor yielded values from 50 °C to 300 °C; the sensitivity obtained was 3.53 a.u./°C, with R2 of 0.99769 and 1% every 1 °C in the transmission. For a range of 50 °C to 150 °C, 20.3 pm/°C with a R2 of 0.96604 was obtained.

2.
Biosensors (Basel) ; 11(2)2021 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-33672317

RESUMO

Vital signs not only reflect essential functions of the human body but also symptoms of a more serious problem within the anatomy; they are well used for physical monitoring, caloric expenditure, and performance before a possible symptom of a massive failure-a great variety of possibilities that together form a first line of basic diagnosis and follow-up on the health and general condition of a person. This review includes a brief theory about fiber optic sensors' operation and summarizes many research works carried out with them in which their operation and effectiveness are promoted to register some vital sign(s) as a possibility for their use in the medical, health care, and life support fields. The review presents methods and techniques to improve sensitivity in monitoring vital signs, such as the use of doping agents or coatings for optical fiber (OF) that provide stability and resistance to the external factors from which they must be protected in in vivo situations. It has been observed that most of these sensors work with single-mode optical fibers (SMF) in a spectral range of 1550 nm, while only some work in the visible spectrum (Vis); the vast majority, operate through fiber Bragg gratings (FBG), long-period fiber gratings (LPFG), and interferometers. These sensors have brought great advances to the measurement of vital signs, especially with regard to respiratory rate; however, many express the possibility of monitoring other vital signs through mathematical calculations, algorithms, or auxiliary devices. Their advantages due to miniaturization, immunity to electromagnetic interference, and the absence of a power source makes them truly desirable for everyday use at all times.


Assuntos
Tecnologia de Fibra Óptica , Monitorização Fisiológica/métodos , Algoritmos , Frequência Cardíaca , Humanos , Interferometria , Fibras Ópticas , Sinais Vitais
3.
Biosensors (Basel) ; 11(3)2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33669087

RESUMO

Diabetes mellitus is a chronic metabolic disorder, being globally one of the most deadly diseases. This disease requires continually monitoring of the body's glucose levels. There are different types of sensors for measuring glucose, most of them invasive to the patient. Fiber optic sensors have been proven to have advantages compared to conventional sensors and they have great potential for various applications, especially in the biomedical area. Compared to other sensors, they are smaller, easy to handle, mostly non-invasive, thus leading to a lower risk of infection, high precision, well correlated and inexpensive. The objective of this review article is to compare different types of fiber optic sensors made with different experimental techniques applied to biomedicine, especially for glucose sensing. Observations are made on the way of elaboration, as well as the advantages and disadvantages that each one could have in real applications.


Assuntos
Técnicas Biossensoriais , Glucose/análise , Tecnologia de Fibra Óptica , Humanos , Fibras Ópticas
4.
J Food Sci ; 86(3): 952-959, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33580559

RESUMO

Dielectric properties (DPs) of fresh rabbit meat in the microwave range (0.5 to 20 GHz) were determined. Three different muscles (Biceps femoris, Tensor fasciae latae, and Longissimus thoracis) from California rabbits (male and female) were measured with the open-ended coaxial probe method at temperatures of 20, 40, and 60 °C. To assess the possible effect of age, females of 100 and 180 days old were analyzed. DPs were affected by frequency, muscle type, age, gender, and temperature (p < 0.05). Dielectric constant decreased with increasing frequency. Loss factor decreased from 0.5 to 2.5 GHz due to ionic conduction, followed by an increase up to 20 GHz, dominated by dipolar relaxation. PRACTICAL APPLICATION: These results are key parameters for further quality sensing applications and for heating processes of meat rabbit using microwaves. Longer penetration depths were achieved at 915 MHz; this frequency is recommended for further applications. Besides, dielectric properties have potential to be a tool for identification of gender and age for slaughtered rabbits.


Assuntos
Manipulação de Alimentos/métodos , Carne , Micro-Ondas , Músculo Esquelético/química , Animais , Eletroquímica , Feminino , Masculino , Coelhos , Temperatura
5.
Sensors (Basel) ; 20(11)2020 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-32517275

RESUMO

In this paper, a gas sensing system based on a conventional absorption technique using a single-mode-fiber supercontinuum source (SMF-SC) is presented. The SC source was implemented by channeling pulses from a microchip laser into a one kilometer long single-mode fiber (SMF), obtaining a flat high-spectrum with a bandwidth of up to 350 nm in the region from 1350 to 1700 nm, and high stability in power and wavelength. The supercontinuum radiation was used for simultaneously sensing water vapor and acetylene gas in the regions from 1350 to 1420 nm and 1510 to 1540 nm, respectively. The experimental results show that the absorption peaks of acetylene have a maximum depth of approximately 30 dB and contain about 60 strong lines in the R and P branches, demonstrating a high sensitivity of the sensing setup to acetylene. Finally, to verify the experimental results, the experimental spectra are compared to simulations obtained from the Hitran database. This shows that the implemented system can be used to develop sensors for applications in broadband absorption spectroscopy and as a low-cost absorption spectrophotometer of multiple gases.

6.
J Food Sci Technol ; 55(8): 3119-3126, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30065422

RESUMO

For microwave heating pasteurization processes, knowledge of the dielectric characteristics of foods are very important. In this paper, we present the dielectric properties of raw soy milk and commercial packed soy milk of four different flavors (light, natural, chocolate and pecan) from 500 MHz to 20 GHz, covering most of the assigned frequencies by the Federal Communications Commission for heating purposes. Experiments were performed using an open-ended-coaxial probe and a vector network analyzer. This characterization was carried out for temperatures ranging from 20 to 70 °C in steps of 10 °C. The dielectric constant of soy milks decreased with increasing frequency, while increasing temperature resulted in decreasing of the values. The dielectric loss factor presents a U shape behavior, where the loss started decreasing from 500 MHz to about 3 GHz and then, it increased again up to 20 GHz. In addition, higher temperatures decreased the dielectric loss. Applying the higher order Debye´s equation, two relaxation times were calculated for the soymilks, with good agreement with the measured properties. Deeper penetration of microwaves were obtained for raw soy milk at 915 MHz, making it suitable for microwave pasteurization.

7.
J Sci Food Agric ; 98(10): 3659-3666, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29250798

RESUMO

BACKGROUND: Hot water treatment (HWT) against Anastrepha ludens was developed achieving 48 °C in the core of grapefruits and holding it for 6 min. After heating, the grapefruits were hydro-cooled and stored at 23 °C and analyzed for 16 days. The effect of microwave-assisted HWT (MW-HWT) on grapefruit quality was analyzed and compared with the quality of fruits treated with HWT and control fruits (without treatment). The physicochemical properties and chemical composition of essential oil were analyzed. RESULTS: MW-HWT was equivalent to HWT according to accumulated heat calculations, with the advantage of being shorter. Treatments significantly affected the weight, color, maturity index, juice content, firmness, titratable acidity, pH, and ascorbic acid content of the grapefruits (P < 0.05), but had no effect on the total soluble solids (P > 0.05). The major components identified in the essential oil were d-limonene and ß-myrcene, compounds responsible of the scent of the grapefruits. CONCLUSION: MW-HWT was shorter (130 min) and had a lesser effect on the quality of the grapefruit when compared with fruits under HWT (188 min duration). Thus, this treatment could be considered as an alternative method against the Mexican fruit fly in grapefruit. © 2017 Society of Chemical Industry.


Assuntos
Citrus paradisi/parasitologia , Conservação de Alimentos/métodos , Frutas/efeitos da radiação , Doenças das Plantas/prevenção & controle , Tephritidae/fisiologia , Animais , Citrus paradisi/química , Citrus paradisi/efeitos da radiação , Cor , Conservação de Alimentos/instrumentação , Frutas/química , Frutas/parasitologia , Temperatura Alta , Micro-Ondas , Doenças das Plantas/parasitologia , Controle de Qualidade
8.
Sensors (Basel) ; 17(10)2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-29053570

RESUMO

A compact, magnetic field sensor system based on a short, bi-tapered optical fiber (BTOF) span lying on a magnetic tape was designed, fabricated, and characterized. We monitored the transmission spectrum from a broadband light source, which displayed a strong interference signal. After data collection, we applied a phase analysis of the interference optical spectrum. We here report the results on two fabricated, BTOFs with different interference spectrum characteristics; we analyzed the signal based on the interference between a high-order modal component and the core fiber mode. The sensor exhibited a linear response for magnetic field increments, and we achieved a phase sensitivity of around 0.28 rad/mT. The sensing setup presented remote sensing operation and low-cost transducer magnetic material.

9.
Comput Math Methods Med ; 2017: 6494390, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28321264

RESUMO

This paper presents a new method based on Estimation of Distribution Algorithms (EDAs) to detect parabolic shapes in synthetic and medical images. The method computes a virtual parabola using three random boundary pixels to calculate the constant values of the generic parabola equation. The resulting parabola is evaluated by matching it with the parabolic shape in the input image by using the Hadamard product as fitness function. This proposed method is evaluated in terms of computational time and compared with two implementations of the generalized Hough transform and RANSAC method for parabola detection. Experimental results show that the proposed method outperforms the comparative methods in terms of execution time about 93.61% on synthetic images and 89% on retinal fundus and human plantar arch images. In addition, experimental results have also shown that the proposed method can be highly suitable for different medical applications.


Assuntos
Simulação por Computador , Pé/diagnóstico por imagem , Retina/diagnóstico por imagem , Vasos Retinianos/diagnóstico por imagem , Algoritmos , Pé/fisiologia , Fundo de Olho , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Retina/fisiologia , Processamento de Sinais Assistido por Computador , Software , Fatores de Tempo
10.
Sensors (Basel) ; 16(6)2016 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-27294930

RESUMO

In this paper, an all-fiber Mach-Zehnder interferometer (MZI) based on a non-zero dispersion-shifted fiber (NZ-DSF) is presented. The MZI was implemented by core-offset fusion splicing one section of a NZ-DSF fiber between two pieces of single mode fibers (SMFs). Here, the NZ-DSF core and cladding were used as the arms of the MZI, while the core-offset sections acted as optical fiber couplers. Thus, a MZI interference spectrum with a fringe contrast (FC) of about 20 dB was observed. Moreover, its response spectrum was experimentally characterized to the torsion parameter and a sensitivity of 0.070 nm/° was achieved. Finally, these MZIs can be implemented in a compact size and low cost.

11.
Sensors (Basel) ; 15(10): 26128-42, 2015 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26501277

RESUMO

In this work a refractive index sensor based on a combination of the non-dispersive sensing (NDS) and the Tunable Laser Spectroscopy (TLS) principles is presented. Here, in order to have one reference and one measurement channel a single-beam dual-path configuration is used for implementing the NDS principle. These channels are monitored with a couple of identical optical detectors which are correlated to calculate the overall sensor response, called here the depth of modulation. It is shown that this is useful to minimize drifting errors due to source power variations. Furthermore, a comprehensive analysis of a refractive index sensing setup, based on an intrinsic micro Fabry-Perot Interferometer (FPI) is described. Here, the changes over the FPI pattern as the exit refractive index is varied are analytically modelled by using the characteristic matrix method. Additionally, our simulated results are supported by experimental measurements which are also provided. Finally it is shown that by using this principle a simple refractive index sensor with a resolution in the order of 2.15 × 10(-4) RIU can be implemented by using a couple of standard and low cost photodetectors.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Interferometria/instrumentação , Refratometria/instrumentação , Desenho de Equipamento
12.
J Food Sci ; 80(5): E1021-5, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25827444

RESUMO

Model gel systems with different shape (sphere, cylinder, and slab) and size (180 and 290 g) were prepared with agar (5%) and sucrose (5%). Dielectric constant (ε'), loss factor (ε"), thermophysical properties, and temperature distribution of the model system were measured. Each agar model system was immersed and suspended in water, and then, heated in a microwave oven with intermittent heating until the core temperature reached 50 °C. The ε' and ε" of agar gels decreased when frequency increased. The density and thermal conductivity values of the agar gels were 1033 kg/m(3) and 0.55 W/m °C, respectively. The temperature distribution of sphere, cylinder, and slab was different when similar power doses were applied. The slab reached 50 °C in less time (10 min) and showed a more uniform heating than spheres and cylinders in both sizes. Agar model systems of 180 g heated faster than those of 290 g. The coldest point was the center of the model systems in all studied cases. Shape and size are critical food factors that affect the heating uniformity during microwave heating processes.


Assuntos
Ágar/química , Manipulação de Alimentos/métodos , Temperatura Alta , Micro-Ondas , Modelos Químicos , Temperatura Baixa , Culinária , Géis , Calefação , Humanos , Condutividade Térmica , Água
13.
Sensors (Basel) ; 13(5): 6355-64, 2013 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-23673676

RESUMO

In this work an Intrinsic Fabry-Perot Interferometer (IFPI) based on an air-microcavity is presented. Here the air microcavity, with silica walls, is formed at a segment of a hollow core photonic crystal fiber (HCPCF), which is fusion spliced with a single mode fiber (SMF). Moreover, the spectral response of the IFPI is experimentally characterized and some results are provided. Finally, the viability to use the IFPI to implement a simple, compact size, and low cost refractive index sensor is briefly analyzed.

14.
Sensors (Basel) ; 13(3): 3028-38, 2013 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-23459386

RESUMO

A compact high temperature fiber sensor where the sensor head consists of a short fattened long period fiber grating (F-LPFG) of at least 2 mm in length and background loss of -5 dBm is reported. On purpose two different F-LPFGs were used to measure temperature variations, taking advantage of their broad spectrum and the slope characteristics of the erbium light source. This approach affected the spectrum gain as the linear band shifting took place. The measured sensitivity of the long period fiber gratings were about 72 pm/°C in a range from 25 to 500 °C. Here, the temperature rate of the experiment was 0.17 °C/s and the temperature response time was within 3 s. Moreover, temperature changes were detected with an InGaAs photodetector, where a sensitivity of 0.05 mV/°C was achieved.


Assuntos
Tecnologia de Fibra Óptica , Temperatura Alta , Fibras Ópticas , Desenho de Equipamento , Humanos
15.
Artigo em Inglês | MEDLINE | ID: mdl-16382631

RESUMO

This paper discusses approximate statistical estimates of limiting errors associated with single differential phase measurement of a time delay (phase difference) between two reflectors of the passive surface acoustic wave (SAW) sensor. The remote wireless measurement is provided at the ideal coherent receiver using the maximum likelihood function approach. Approximate estimates of the mean error, mean square error, estimate variance, and Cramér-Rao bound are derived along with the error probability to exceed a threshold in a wide range of signal-to-noise ratio (SNR) values. The von Mises/Tikhonov distribution is used as an approximation for the phase difference and differential phase diversity. Simulation of the random phase difference and limiting errors also is applied.

16.
Opt Express ; 13(9): 3388-96, 2005 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-19495241

RESUMO

We report experimental observations of stimulated Raman scattering in a standard fiber using a directly modulated DFB semiconductor laser amplified by two erbium-doped fibers. The laser pulse width was variably controlled on a nanosecond-scale; the laser emission was separated into two distinct regimes: an initial transient peak regime, followed by a quasi steady-state plateau regime. The transient leading part of the pump pulse containing fast amplitude modulation generated a broadband Raman-induced spectral shift through the modulation instability and subsequent intra-pulse Raman frequency shift. The plateau regime amplified the conventional Stokes shifted emission expected from the peaks of the gain distribution. The output signal spectrum at the end of a 9.13 km length of fiber for the transient part extends from 1550 nm to 1700 nm for a pump pulse peak power of 65 W. We found that the Raman-induced spectral shift is measurable about 8 W for every fiber length examined, 0.6 km, 4.46 km, and 9.13 km. All spectral components of the broadband scattering appear to be generated in the initial kilometer of the fiber span. The Stokes shifted light generation threshold was higher than the threshold for the intra-pulse Raman-induced broadened spectra. This fact enables the nonlinear spectral filtering of pulses from directly modulated semiconductor lasers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...