Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 48(1): 96-9, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10467081

RESUMO

Coronary stenting has begun to play an increasingly important role in the management of coronary artery aneurysms. A case of successful and complete sealing of a coronary aneurysm by using a new stent graft is described. Further studies in a large patient population are required to confirm the safety and efficacy of this method. Cathet. Cardiovasc. Intervent. 48:96-99, 1999.


Assuntos
Aneurisma Coronário/terapia , Stents , Idoso , Angioplastia Coronária com Balão , Aneurisma Coronário/complicações , Aneurisma Coronário/diagnóstico por imagem , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/terapia , Humanos , Masculino
2.
Catheter Cardiovasc Interv ; 46(3): 363-7, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10348142

RESUMO

The intracoronary stent placement in a lesion proximal to a myocardial bridge is of special importance and is considered to be a challenge for the interventional cardiologist. In this study 4 cases of stent implantation proximal to a coronary bridged segment are described. In all cases complications were observed after the procedure. The patients remained free of symptoms and the exercise TI201 test was negative for ischemia 8.5+/-2.6 months later. Although there is skepticism because of the abnormal coronary flow pattern, the endothelial dysfunction and the subsequent thrombogenicity, the stent placement proximal to a myocardial bridge was safe and with favorable long term results in all 4 cases. However, further studies in large populations are necessary.


Assuntos
Anomalias dos Vasos Coronários/terapia , Stents , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
3.
Angiology ; 50(5): 381-91, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10348426

RESUMO

Intracoronary stenting has been shown to reduce acute closure and restenosis rate in patients treated with coronary angioplasty. The use of high inflation pressures and intravascular ultrasound guidance allowed the substitution of anticoagulants with antiplatelet agents but increased the cost. The aim of this study was to investigate the effectiveness, safety, and long-term outcome of the elective implantation of a relatively new type of stent (Micro-Stent II), without the use of quantitative coronary angiography or intravascular ultrasound guidance and without subsequent anticoagulation. The study included 361 patients who underwent elective microstent implantation. Stent expansion was performed at 8 atm followed by higher inflation pressure at 14-20 atm. Heparin was given intraarterially only once immediately after the arterial sheath insertion. Ticlopidine was started at least 48 hours before the procedure and continued for 1 month while aspirin was continued indefinitely. All patients were followed up for 12.9 +/- 3.6 months. Short term outcome (first month): Stent implantation was successfully achieved in 361 of 366 patients (98.6%). Seven patients (1.9%) were excluded from the study and received anticoagulants because of a suboptimal result. In total, 423 stents were implanted. There was no subacute thrombosis, but acute vessel closure occurred in one patient (0.3%). Non-Q wave myocardial infarction occurred in six patients (1.7%), Q wave myocardial infarction occurred in one patient (0.3%), and only one death (0.3%) of nonischemic origin was reported. No major peripheral vascular complications were observed. Late results: Q or non-Q wave infarction occurred in 13 patients (3.6%), 26 patients (7.2%) underwent a repeat angioplasty, eight patients (2.2%) underwent coronary artery bypass grafting, and four patients (1.1%) died. Overall, 284 patients (78.7%) were free of symptoms, while 77 (21.3%) had recurrent coronary ischemia. In conclusion, Micro-Stent II implantation without quantitative coronary angiography or intravascular ultrasound guidance and without anticoagulation was found to be effective, safe, and with good long-term outcome.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Stents , Anticoagulantes/uso terapêutico , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
Cathet Cardiovasc Diagn ; 45(2): 183-7, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9786400

RESUMO

Stent dislodgment from the delivery catheter is a well-known complication of angioplasty with stent implantation. The aim of our study was to investigate the feasibility, effectiveness, and safety of a new technique of intracoronary stent implantation in order to avoid stent loss in the intravascular space. Fifty consecutive patients were candidates for angioplasty and stent placement. During angioplasty, a technique was followed according to which the guide wire "hindered" the dislodgment of the stent from the balloon catheter. Successful angioplasty and stent placement were performed in 46 out of 50 patients (92% success rate). In three cases of failure of stent implantation, the stent moved onto the balloon catheter; however, this was impeded by the guide wire. One non-Q-wave myocardial infarction occurred. No major complications (Q-wave myocardial infarction, CABG, or death) were observed. In conclusion, the technique applied was feasible enough, safe, and effective. However, the appropriate modification of its "hardware" will render it even more feasible and user-friendly.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Doença das Coronárias/terapia , Stents , Adulto , Idoso , Estudos de Viabilidade , Feminino , Migração de Corpo Estranho/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Stents/efeitos adversos
5.
Cathet Cardiovasc Diagn ; 44(1): 75-6, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9600529

RESUMO

A case of angiographic catheter entrapment in the right coronary artery during coronary angiography in a patient with excessive tortuosity of the right iliac artery is described. Alternative manipulations in order to avoid this problem are presented.


Assuntos
Angina Instável/diagnóstico por imagem , Angiografia Coronária/instrumentação , Vasos Coronários , Corpos Estranhos/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Doença da Artéria Coronariana/diagnóstico por imagem , Falha de Equipamento , Humanos , Doença Iatrogênica , Artéria Ilíaca/diagnóstico por imagem , Masculino , Fatores de Risco
6.
Int J Cardiol ; 63(1): 75-80, 1998 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-9482148

RESUMO

The case of a patient with unstable angina and angiographic findings of significant (approximately 90%) right coronary artery stenosis with an intracoronary thrombus next to the lesion, total left anterior descending and circumflex occlusion and an ejection fraction of approximately 22% is described. The case was treated with stent implantation after local thrombolysis with the use of the Dispatch infusion catheter.


Assuntos
Implante de Prótese Vascular , Trombose Coronária/terapia , Ativadores de Plasminogênio/uso terapêutico , Stents , Terapia Trombolítica , Ativador de Plasminogênio Tipo Uroquinase/uso terapêutico , Disfunção Ventricular Esquerda/terapia , Cateterismo , Angiografia Coronária , Trombose Coronária/complicações , Trombose Coronária/diagnóstico por imagem , Eletrocardiografia , Seguimentos , Humanos , Infusões Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Ativadores de Plasminogênio/administração & dosagem , Volume Sistólico , Terapia Trombolítica/instrumentação , Ativador de Plasminogênio Tipo Uroquinase/administração & dosagem , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem
8.
Cathet Cardiovasc Diagn ; 42(1): 61-3, 1997 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-9286544

RESUMO

In this report we describe a case in which a saphenous vein graft stenosis at the site of anastomosis with the left anterior descending artery (LAD) was dilated with a special Controlled Angioplasty Technology (CAT) balloon, and then stented. Balloon angioplasty and stenting at the site of anastomosis represents a technical problem because of diameter discrepancy and needs special attention in order to avoid minor or major complications.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Vasos Coronários/cirurgia , Veia Safena/transplante , Stents , Idoso , Anastomose Cirúrgica , Constrição Patológica , Estudos de Viabilidade , Humanos , Masculino
9.
Cathet Cardiovasc Diagn ; 41(4): 445-8, 1997 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9258496

RESUMO

The "Y connector" that is used in angioplasty has the following disadvantages: 1) it is not blood-tight; 2) we need to "screw and unscrew" every time we want to inject contrast material or measure the pressure; and 3) it does not allow the advancement of the guidewire or the balloon catheter during the injection of contrast material. We created a new type of connection composed of a cut sheath for the femoral artery, connected with a cut (at the "hub") guiding catheter. The aim of this study was to examine the feasibility, efficacy, and safety of the new method. Using the new technique we performed plain-balloon angioplasty, implantation of stent, and atherectomy in 350 patients. The technical success of the method was 100%, and no complications related to the method were seen. In conclusion, the novel connection that we created eliminated all the disadvantages of the "Y connector" and was found to have 100% technical success and safety.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Desenho de Equipamento , Estudos de Viabilidade , Humanos
10.
Int J Cardiol ; 28(3): 382-3, 1990 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2210908

RESUMO

A case with syncope on exertion and paced heart block is presented. Non-sustained ventricular tachycardia was seen on Holter monitoring and reproduced repeatedly by either exercise or an injection of an alpha agonist, but not with provocative electrophysiology. Antihypertensive treatment using a beta-blocker with endogenous sympathomimetic activity prevented recurrences. It is suggested that this is a case of pressure-related tachycardia.


Assuntos
Hipertensão/complicações , Taquicardia/etiologia , Eletrocardiografia Ambulatorial , Exercício Físico , Feminino , Humanos , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...