1.
Food Chem ; 141(3): 2614-7, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-23871002

RESUMO

In the present study, a simple, rapid and sensitive method was developed for the determination of mercury concentrations in the muscle tissue of fish from the Brazilian Amazon using graphite furnace atomic absorption spectrometry (GFAAS) following acid mineralization of the samples in an ultrasonic cold water bath. Using copper nitrate as a chemical modifier in solution and sodium tungstate as permanent modifier, we were able to attain thermal stabilization of the mercury up to the atomisation temperature of 1600 °C in the GFAAS assay. The calculated limits of detection (LOD) and quantification (LOQ) were 0.014 and 0.047 mg kg(-1), respectively.


Assuntos
Mercúrio/análise , Músculo Esquelético/química , Alimentos Marinhos/análise , Espectrofotometria Atômica/métodos , Animais , Brasil , Peixes , Contaminação de Alimentos/análise , Limite de Detecção
2.
Anal Sci ; 20(7): 1029-32, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15293396

RESUMO

A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT). The Cd2+ ions were sorbed at pH 5.0. The preconcentrated Cd2+ ions were directly eluted from the column to the spectrometer's nebulizer-burner system using 100 microL of 2 mol L(-1) hydrochloric acid. A retention efficiency of over 95% was achieved. The enrichment factor (calculated as the ratio of slopes of the calibration graphs) obtained with preconcentrations in a mini-column packed with SiAT (A = -1.3 x 10(-3) + 1.8 x 10(-3)[Cd2+]) and without preconcentrations (A = 4 x 10(-5) + 3.5 x 10(-5)[Cd2+]), was 51 and the detection limit calculated was 0.38 microg L(-1). The preconcentration procedure was applied to determine trace levels of Cd in river water samples. The optimum preconcentration conditions are discussed herein.


Assuntos
Cádmio/análise , Dióxido de Silício/química , Espectrofotometria Atômica/métodos , Tiazóis/farmacologia , Água/análise , Cádmio/química , Calibragem , Ácido Clorídrico/farmacologia , Concentração de Íons de Hidrogênio , Íons , Modelos Químicos , Sílica Gel , Espectrofotometria , Espectrofotometria Infravermelho , Fatores de Tempo