Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BMC Gastroenterol ; 24(1): 114, 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500056

RESUMO

Surface electroenterography is a potential non-invasive alternative to current diagnostics of colonic motility disorders. However, electrode positioning in electroenterography is often based on general anatomy and may lack generalizability. Furthermore, the repeatability of electroenterography measurements is unknown. This study aimed to evaluate ultrasound-guided electrode positioning for electroenterography measurements and to determine the repeatability of those measurements. In ten healthy adults, two electroenterography procedures were performed, consisting of fasting, ultrasound-guided electrode localization and two 20-minute electroenterography recordings separated by a meal. The dominant frequency, the mean power density (magnitude of colonic motility) and the power percent difference (relative pre- to postprandial increase in magnitude) were determined. Repeatability was determined by Lin's concordance correlation coefficient. The results demonstrated that the dominant frequency did not differ between pre- and postprandial recordings and was 3 cpm, characteristic of colonic motility. The mean power density increased between the pre- and postprandial measurements, with an average difference of over 200%. The repeatability of both the dominant frequency and power density was poor to moderate, whereas the correlation coefficient of the power percent difference was poor. Concluding, ultrasound-guided surface electroenterography seems able to measure the gastrocolic reflex, but the dissatisfactory repeatability necessitates optimization of the measurement protocol.


Assuntos
Colo , Jejum , Adulto , Humanos , Estudos de Viabilidade , Colo/diagnóstico por imagem , Ultrassonografia de Intervenção , Motilidade Gastrointestinal
2.
Sci Rep ; 14(1): 3585, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351192

RESUMO

Current diagnostics in Hirschsprung's disease are often challenging and invasive. This study aims to investigate whether surface electroenterography can non-invasively discern healthy subjects from subjects suffering from Hirschsprung's disease. Nine healthy subjects (seven children, two adults) and eleven subjects suffering from surgically untreated Hirschsprung's disease (nine children, two adults) underwent an electroenterography procedure. This procedure consisted of ultrasound-guided placement of surface electrodes on the abdomen covering all parts of the colon, fasting and two 20-min electroenterography measurements separated by a meal. The dominant frequency, magnitude and relative increase (pre- to postprandial) of colonic activity were compared between both groups. The results showed that in the pediatric group, no significant differences in dominant frequency, colonic activity and relative power increase were observed between controls and patients. The adult patients showed decreased colonic motility and relative power increase in the electrodes closest to the distal colon, both when compared to the same electrodes in controls and to the more proximal electrodes of themselves. To conclude, electroenterography measurements in young children is challenging, but the results in adults demonstrate that these measurements can possibly distinguish between controls and Hirschsprung's patients. Therefore, optimization of electroenterography measurements in young children is necessary.


Assuntos
Doença de Hirschsprung , Adulto , Humanos , Criança , Lactente , Pré-Escolar , Doença de Hirschsprung/diagnóstico , Estudos de Viabilidade
3.
J Ren Nutr ; 33(1): 193-200, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34922812

RESUMO

OBJECTIVES: The body composition monitor (BCM) is a bioimpedance spectroscopy device, specifically developed for patients on hemodialysis (HD) to improve ultrafiltration (UF) programming, based on an objective assessment of the degree of overhydration (OH) at the start of HD. However, its acceptance in clinical practice remains limited because of concerns about the accuracy at the individual level. The aim of this study is to examine the performance of the BCM and to identify means of improvement. METHODS: Precision of the OH estimate was assessed by 6 consecutive measurements in 24 patients on HD. Accuracy was examined in 45 patients, by comparing the change in OH (ΔOH) during HD with UF volume. Accuracy was considered acceptable if the volume error in individual patients was ≤0.5 L. RESULTS: The OH estimate had an analytical precision of 1.0 ± 0.4%. The correlation between UF volume and ΔOH was moderate (Slope = 0.66, R2 = 0.44, P < .001) and indicated underestimation of UF volume, in particular for high UF volumes. Accuracy at individual level was highly variable. A volume error >0.5 L occurred in 44% of patients. Accuracy improved over the course of HD, with a decrease in total error range from 2.3 L in the first hour to 1.1 L in the final hour of HD. CONCLUSIONS: The accuracy of BCM volume change estimates is highly variable and below requirements of daily practice. Improvement may be achieved by a switch to an end-of-HD measurement.


Assuntos
Composição Corporal , Diálise Renal , Humanos , Diálise Renal/métodos , Impedância Elétrica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...