Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Opt ; 19(4): 047001, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24699633

RESUMO

Ischemia-reperfusion injuries are a critical determinant of lung transplantation success. The endogenous production of carbon monoxide (CO) is triggered by ischemia-reperfusion injuries. Our aim was, therefore, to assess the feasibility of exhaled CO measurements during the ex vivo evaluation of lungs submitted to ischemia-reperfusion injuries. Five pigs were euthanized and their lungs removed after pneumoplegia. After cold storage (30 min, 4°C), the lungs were connected to an extracorporeal membrane oxygenation circuit, slowly warmed-up, and ventilated. At the end of a 45-min steady state, CO measurements were performed by optical-feedback cavity-enhanced absorption spectroscopy, a specific laser-based technique for noninvasive and real-time low gas concentration measurements. Exhaled CO concentration from isolated lungs reached 0.45±0.19 ppmv and was above CO concentration in ambient air and in medical gas. CO variations peaked during the expiratory phase. Changes in CO concentration in ambient air did not alter CO concentrations in isolated lungs. Exhaled CO level was also found to be uncorrelated to heme oxygenase (HO-1) gene expression. These results confirm the feasibility of accurate and real-time CO measurement in isolated lungs. The presented technology could help establishing the exhaled CO concentration as a biomarker of ischemia-reperfusion injury in ex vivo lung perfusion.


Assuntos
Monóxido de Carbono/análise , Monóxido de Carbono/metabolismo , Pulmão/metabolismo , Análise Espectral/métodos , Animais , Heme Oxigenase-1/metabolismo , Lasers , Lesão Pulmonar/metabolismo , Monitorização Fisiológica/métodos , Traumatismo por Reperfusão/metabolismo , Sus scrofa , Suínos
2.
J Biomed Opt ; 14(6): 064026, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-20059264

RESUMO

We demonstrate a first application, of optical-feedback cavity-enhanced absorption spectroscopy (OF-CEAS) to breath analysis in a medical environment. Noninvasive monitoring of trace species in exhaled air was performed simultaneous to spirometric measurements on patients at Bichat Hospital (Paris). The high selectivity of the OF-CEAS spectrometer and a time response of 0.3 s (limited by sample flow rate) allowed following the evolution of carbon monoxide and methane concentrations during individual respiratory cycles, and resolving variations among different ventilatory patterns. The minimum detectable absorption on this time scale is about 3 x 10(-10) cm(-1). At the working wavelength of the instrument (2.326 microm), this translates to concentration detection limits of approximately 1 ppbv (45 picomolar, or approximately 1.25 microg/m(3)) for CO and 25 ppbv for CH(4), well below concentration values found in exhaled air. This same instrument is also able to provide measurement of NH(3) concentrations with a detection limit of approximately 10 ppbv; however, at present, memory effects do not allow its measurement on fast time scales.


Assuntos
Testes Respiratórios/métodos , Monóxido de Carbono/análise , Metano/análise , Análise Espectral/métodos , Testes Respiratórios/instrumentação , Retroalimentação , Humanos , Sensibilidade e Especificidade , Fumar , Análise Espectral/instrumentação , Espirometria , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...