Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
1.
Eur J Ophthalmol ; : 11206721241254132, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38751124

RESUMO

PURPOSE: To describe a case of peripapillary pachychoroid syndrome (PPS) in a diabetic patient with cystoid macular edema (CME), treated with intravitreal dexamethasone implant (IDI) injection. This report also illustrates the history of the disease after repeated IDI and dexamethasone topical treatment. METHODS: A case report. RESULTS: A 77-year old male patient with PPS and good diabetic control was treated with dexamethasone implant for CME. After an initial morphofunctional improvement associated with a first IDI, the disease relapsed after the second dexamethasone implant injection. This was associated with a significant increase in both intraretinal fluid and choroidal thickness, with subsequent visual acuity (VA) decrease. At this point, a topical dexamethasone treatment was performed and, despite a morphological improvement, VA worsened compared with baseline, likely because of anatomical damage. CONCLUSION: In this report, the importance of the recognition of PPS is underlined and the possible occurrence of a "rebound" effect due to repeated IDI is described.

2.
Eur J Ophthalmol ; 34(3): 888-892, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38409807

RESUMO

BACKGROUND: Various ocular implants were suggested as a means of enhancing vision in patients with advanced age related macular degeneration. Recently, a new generation of implantable telescopes has been released. The purpose of this study is to report the surgical technique of implantation along with patient outcomes. METHODS: This work focuses on the surgical technique. Crucial surgical steps are carefully reported along with discussion on main drawbacks and limitations. RESULTS: This approach uses a preloaded delivery system with improved features and requires a smaller incision. First patient outcomes are also reported. CONCLUSIONS: Surgical steps to implant this preloaded intraocular telescope are easier than previous versions, however this remains a complex procedure. Initial patient functional outcomes look promising.


Assuntos
Telescópios , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Degeneração Macular/cirurgia , Idoso , Miniaturização
3.
Eur J Ophthalmol ; 34(3): NP18-NP21, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38254249

RESUMO

PURPOSE: We report a series of 5 cases, happened in a period of 5 months, who developed neurotrophic keratopathy (NK) following pars plana vitrectomy (PPV) and retinal endolaser for rhegmatogenous retinal detachment (RRD). In our several decennary experience of surgical center predominantly based on vitreoretinal surgery, we had rare cases of postoperative NK. These recent cases of post-surgical NK happened contextually to our change of postoperative non-steroidal anti-inflammatory drugs (NSAIDs) drops, based on Ketorolac Tromethamine 0.5% eye drops. CASES PRESENTATION: Five patients with a mean age of 61 ± 7.3 years were treated with one or more PPV with intraoperative peripheral endolaser for RRD. Nobody had previous herpetic keratitis, systemic disease like diabetes mellitus or other predisposing factors for NK. In the postoperative period, all patients received Ketorolac Tromethamine 0.5% eye drops for a mean period of 54 ± 25 days. During follow-up visits they developed NK and they were successfully treated with suspension of Ketorolac eye drops, application of therapeutic contact lens or amniotic membrane patch and topical lubricant therapy. CONCLUSIONS: Postoperative Ketorolac eye drops, in patients who underwent PPV with endolaser, may reduce the corneal sensitivity, predispose to epithelial disruption and NK development. Studies are needed to explore the effect of NSAIDs on corneal sensitivity reduction in patient who will undergo PPV and extensive endolaser.


Assuntos
Anti-Inflamatórios não Esteroides , Soluções Oftálmicas , Descolamento Retiniano , Vitrectomia , Humanos , Pessoa de Meia-Idade , Feminino , Masculino , Anti-Inflamatórios não Esteroides/administração & dosagem , Idoso , Descolamento Retiniano/cirurgia , Complicações Pós-Operatórias , Doenças da Córnea/cirurgia , Doenças da Córnea/diagnóstico , Cetorolaco de Trometamina/administração & dosagem , Cetorolaco de Trometamina/uso terapêutico , Acuidade Visual , Cetorolaco/administração & dosagem , Cetorolaco/uso terapêutico
4.
Am J Ophthalmol ; 261: 165-175, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38211781

RESUMO

PURPOSE: To investigate the reduction of the ocular surface bacterial load induced by 2 commercially available ophthalmic antiseptic formulations, povidone-iodine (PVI) 0.6% and chlorhexidine (CLX) 0.02%, before ocular surgery. DESIGN: Randomized controlled trial. METHODS: Seventy adult patients undergoing intraocular surgery (phacoemulsification) were randomized to receive in the index eye PVI (group A) 4 times a day for 3 days or CLX (group B) 4 times a day for 3 days before surgery. The untreated eye was used as control. A conjunctival swab was taken in both eyes before (T0) and after (T1) therapy. Microbial DNA was quantified with real-time polymerase chain reaction (PCR) analysis. The Mick algorithm was used to compare the abundance of each genus/genera against the distribution of abundances from the reference. At T1, patients filled a questionnaire to evaluate therapy-induced symptoms. Primary outcome was the reduction of bacterial DNA at T1 (microbial load), vs control arm, expressed as mean number of real-time PCR cycle times (CTs). Secondary outcomes were taxonomic composition, differential abundance, and therapy-induced ocular symptoms. RESULTS: The T0-T1 difference in CT was significant in group B, but not in group A (mean [95% CI], 0.99 [0.33] vs 0.26 [0.15], P < .001, and 0.65 [0.3] vs 0.45 [0.41], P = .09, respectively). The taxonomic composition, alpha, and beta diversity remained consistent at all time points in both groups. The rate of patients reporting therapy-induced ocular symptoms and the mean discomfort grade were greater in group A than in group B (97% vs 26% and 4.97±2.48 vs 0.66±1.53, respectively). CONCLUSIONS: Compared with PVI 0.6%, CLX 0.02% induced a greater reduction of ocular surface bacterial load, with no significant alterations of the taxonomic composition. Moreover, CLX was better tolerated than PVI.


Assuntos
Anti-Infecciosos Locais , Oftalmologia , Adulto , Humanos , Carga Bacteriana , Povidona-Iodo , Clorexidina/uso terapêutico , Túnica Conjuntiva/microbiologia , Soluções Oftálmicas
6.
Eye (Lond) ; 38(2): 315-320, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-37524832

RESUMO

PURPOSE: To the describe OCT imaging characteristics of a cohort of patients showing spontaneously closing degenerative or mixed type lamellar macular holes (LMH) and to compare them to the ones of a sex and age matched group showing stable lesions. METHODS: Patients diagnosed with degenerative and mixed type LMHs showing OCT-documented spontaneous anatomical closure were retrospectively selected from 3 specialized retina centres. An equal number of age and sex matching subjects were randomly selected among patients with anatomically stable lesions. RESULTS: Eleven (11) spontaneously closing (SC group) and 11 stable (ST group) degenerative LMH with a mean follow up of 4 years were recruited. Hyperreflective inner border (HIB) and linear hyperreflectivity in the outer plexiform layer (LHOP) at baseline were significantly more prevalent in SC group in processed images (respectively p = 0.007 and p = 0.003). A borderline significance in lamellar hole associated epiretinal proliferation (LHEP) at last follow up was detected (p = 0.085). As for mixed type LMH, 10 patients for SC group and 10 for ST group were recruited. LHOP at baseline in processed images was significantly more prevalent in SC group (p = 0.005). CONCLUSIONS: Spontaneously closing LMHs show higher prevalence of HIB and LHOP at the beginning of the closing process, a difference which is enhanced by image processing. These signs might be a signal of microglial and Muller cells coordinated activation.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Humanos , Perfurações Retinianas/diagnóstico por imagem , Membrana Epirretiniana/diagnóstico , Estudos Retrospectivos , Acuidade Visual , Tomografia de Coerência Óptica/métodos , Seguimentos
7.
Retina ; 44(1): 102-110, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37695945

RESUMO

PURPOSE: To study visual function, retinal layer thickness changes, and tangential displacement after pars plana vitrectomy for epiretinal membrane. METHODS: Retrospective series of patients undergoing pars plana vitrectomy for epiretinal membrane, with 6-month follow-up including best-corrected visual acuity, optical coherence tomography, M-charts, epiretinal membrane grading, and infrared fundus photograph at time 0 (T0, preop) at months 1 (T1), 3 (T3), and 6 (T6) postop (±1 week). Retinal layer thickness and tangential ( en face ) retinal displacement between successive times for the entire retinal surface and the central horizontal and vertical meridian were also measured. En face displacement was calculated as optical flow of consecutive images. RESULTS: Average best-corrected visual acuity improved from 0.28 ± 0.08 logarithm of Minimum Angle of Resolution at T0 to 0.16 ± 0.25 at T6 ( P = 0.05), best-corrected visual acuity improvement correlated with best corrected visual acuity (BCVA) at T0 ( P < 0.001). Vertical metamorphopsia decreased from 1.33° ± 0.70° at T0 to 0.82° ± 0.69° at T6 ( P < 0.05). Foveal thickness reduced from 453 ± 53 µ m at T0 to 359 ± 31 µ m at T6 ( P < 0.05) and reduction correlated with best-corrected visual acuity improvement ( P < 0.05). Foveal layers decreased ( P < 0.05) in all cases. The mean en face deformation was 155.82 ± 50.17 µ m and mostly occurred in the first month: T0-T1 displacement was 83.59 ± 30.28 µ m, T1-T3 was 36.28 ± 14.45 µ m, while T3-T6 was 39.11 ± 22.79 µ m ( P < 0.001) on average. Perifoveal and parafoveal deformation correlated with optical coherence tomography foveal thickness reduction at all time intervals (1, 3, and 6 months: P < 0.01). CONCLUSION: Epiretinal membrane peeling affects all retinal layer thickness and results in new force balance across the entire retina and tangential displacement. Both en face and in-depth changes correlate with visual function.


Assuntos
Membrana Epirretiniana , Humanos , Membrana Epirretiniana/cirurgia , Estudos Retrospectivos , Acuidade Visual , Retina , Fóvea Central , Tomografia de Coerência Óptica/métodos , Vitrectomia/métodos
8.
Retina ; 44(4): 610-617, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37973044

RESUMO

PURPOSE: To measure the tangential retinal displacement and vision before and after macular pucker surgery and study if pars plana vitrectomy with epiretinal membrane peeling allows the reconstitution of previous anatomy or else it results in a different configuration. METHODS: Retrospective series of patients undergoing pars plana vitrectomy for epiretinal membrane, with >6-month follow-up before and after surgery, complete with best-corrected visual acuity, optical coherence tomography, M-Charts, and infrared retinography. Tangential retinal displacement between earliest visit (T E ), time of surgery (T 0 ), and latest available visit (T L ) of the examined retina, concentric circles at 0.5, 1.5, and 4.5 mm radii, and the central horizontal and vertical meridians were measured. Tangential displacement was calculated as the optical flow of consecutive infrared photographs. RESULTS: The study comprised 32 patients: 15 men and 17 women. Average preoperative and postoperative follow-up were 23.4 ± 27.9 months and 19.2 ± 11.8 months, respectively. Best-corrected visual acuity reduced before surgery (0.69 ± 0.16 Snellen to 0.46 ± 0.17; P < 0.001) and increased after (0.866 ± 0.16 Snellen; P < 0.001). Horizontal and vertical metamorphopsia increased between before surgery but only horizontal metamorphopsia significantly reduced after. Average tangential displacement before surgery was 35.6 ± 29.9 µ m versus 56.6 ± 41.3 µ m after ( P = 0.023). Preoperative and postoperative displacement within the fovea was less than over the entire area ( P < 0.001). CONCLUSION: Retinal tangential displacement between diagnosis and surgery (T E - T 0 ) is less than the displacement occurring after surgery (T 0 - T L ). Postoperative displacement does not represent the restoration of the anatomy existing before the disease ensued but rather the resulting equilibrium of newly deployed forces.


Assuntos
Membrana Epirretiniana , Masculino , Humanos , Feminino , Membrana Epirretiniana/cirurgia , Estudos Retrospectivos , Complicações Pós-Operatórias/cirurgia , Retina , Tomografia de Coerência Óptica/métodos , Transtornos da Visão/cirurgia , Vitrectomia/métodos
9.
Graefes Arch Clin Exp Ophthalmol ; 262(2): 431-440, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37843567

RESUMO

PURPOSE: To assess the validity of the results of a freely available online Deep Learning segmentation tool and its sensitivity to noise introduced by cataract. METHODS: The OCT images were collected with a Spectralis SD-OCT (Heidelberg Engineering, Heidelberg, Germany) as part of normal clinical practice. Data were segmented using a freely available online tool called Relayer ( https://www.relayer.online/ ), based on a cross-platform Deep Learning segmentation architecture specifically adapted for retinal OCT images. The segmentations were read into MATLAB (The MathWorks, Natick, MA, USA) and analyzed. RESULTS: There was an excellent agreement between the ETDRS measurements obtained from the two algorithms. Upon visual inspection, the segmentation based on Deep Learning obtained with Relayer appeared more accurate except in one case of apparent good quality image showing interrupted segmentations in some of the B-scans. CONCLUSION: A freely available online Deep Learning segmentation tool showed good and promising performance in healthy retinas before and after cataract surgery, proving robust to optical degradation of the image from media opacities.


Assuntos
Catarata , Aprendizado Profundo , Humanos , Tomografia de Coerência Óptica/métodos , Retina , Catarata/diagnóstico , Algoritmos
10.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1141-1149, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38038728

RESUMO

PURPOSE: To propose a minimum specification dataset to characterize liquid ocular endotamponades (OEs), namely silicone oil (SO), heavy SO (HSO), perfluorodecalin (PFD), and perfluoro-octane (PFO), in terms of physicochemical properties, purity and available evidence of safety, in line with ISO16672:2020. METHODS: An evidence-based consensus using the expert panel technique was conducted. Two facilitators led a committee of 11 European experts. Facilitators prepared a dataset for each compound including the list of specifications relevant for the safety, identified by the group members on the basis of expertise and a comprehensive literature review. Each item was ranked by each member using a 9-point scale from 1 "absolutely to not include" to 9 "absolutely to include" in two rounds followed by discussion. Only items reaching consensus (score ≥ 7 from ≥ 75% of members) were included in the final datasets. RESULTS: For all OEs, consensus was reached to include manufacturer, density, refractive index, chemical composition, dynamic viscosity, interfacial and surface tension, endotoxins, in vitro cytotoxicity assessment, and any evidence from ex vivo and/or in vivo tests for safety assessment. Additional specifications were added for SO (molecular weight distribution, content of oligosiloxanes with MW ≤ 1000 g/mol, spectral transmittance) and PFD/PFO (% of pure PFD/PFO in the final product, vapor pressure, chemical analyses performed for safety assessment). CONCLUSION: The proposed evidence-based minimum specification datasets for SO, HSO, PFD, and PFO have the potential to provide surgeons and health service purchasers with an easily available overview of the most relevant information for the safety assessment of OEs.


Assuntos
Olho , Fluorocarbonos , Humanos , Tamponamento Interno
12.
Surv Ophthalmol ; 69(3): 362-377, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38160737

RESUMO

Subretinal hyperreflective material (SHRM) is a common and remarkable optical coherence tomography (OCT) biomarker whose importance is emerging in several retinal and chorioretinal diseases, including age-related macular degeneration, central serous chorioretinopathy, polypoidal choroidal vasculopathy, pathologic myopia, posterior uveitis, vitelliform lesions and macular dystrophies, and rarer disorders. Multimodal imaging, also thanks to the introduction of OCT angiography, allowed a deeper characterisation of SHRM components and its morphological changes after treatment, suggesting its usefulness in clinical practice. We discuss and summarize the nature, multimodal imaging characteristics, and prognostic and predictive significance of SHRM in the different retinal and choroidal disorders in which it has been described.


Assuntos
Doenças da Coroide , Angiofluoresceinografia , Doenças Retinianas , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Doenças Retinianas/diagnóstico , Doenças da Coroide/diagnóstico , Angiofluoresceinografia/métodos , Imagem Multimodal/métodos , Retina/patologia , Retina/diagnóstico por imagem
13.
Artigo em Inglês | MEDLINE | ID: mdl-38060000

RESUMO

PURPOSE: The aim of this article is to conduct a comprehensive systematic review about the current understandings and differential diagnosis of myopic choroidal neovascularization (mCNV) and other several similar diseases, describing their multimodal imaging analysis, prognostic implications, and current types of management. METHODS: This systematic review was performed based on a search on the PubMed database of relevant papers regarding mCNV and other entities discussed in the paper, according to our current knowledge. RESULTS: Through the integration of a multimodal imaging approach, especially optical coherence tomography (OCT), along with accurate demographic and clinical assessment, it becomes possible to effectively differentiate mCNV from similar yet heterogeneous entities. These conditions include macular hemorrhage due to new lacquer crack (LC) formation, inflammatory diseases such as punctate inner choroidopathy (PIC)/multifocal choroidits (MFC) and epiphenomenon multiple evanescent white dot syndrome (Epi-MEWDS), neovascular age-related macular degeneration (nAMD), idiopathic CNV (ICNV), dome-shaped macula (DSM) with subretinal fluid, retinal pigment epithelium (RPE) humps, angioid streaks (AS), choroidal rupture (CR), and choroidal osteoma (CO). Each one of these entities will be described and discussed in this article. CONCLUSION: Myopic choroidal neovascularization is a common retinal condition, especially among young individuals. Accurate diagnosis and differentiation from similar conditions are crucial for effective treatment. Multimodal imaging, particularly OCT, plays a crucial role in precise assessment. Future research should focus on defining biomarkers and distinguishing features to facilitate prompt treatment.

14.
Int J Mol Sci ; 24(13)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37445711

RESUMO

Subretinal injection is performed in vitreoretinal surgery with two main aims, namely, the subretinal delivery of therapeutic agents and subretinal injection of fluid to induce a controlled and localized macular detachment. The growing interest in this technique is mainly related to its suitability to deliver gene therapy in direct contact with target tissues. However, subretinal injection has been also used for the surgical management of submacular hemorrhage through the subretinal delivery of tissue plasminogen activator, and for the repair of full-thickness macular holes, in particular refractory ones. In the light of the increasing importance of this maneuver in vitreoretinal surgery as well as of the lack of a standardized surgical approach, we conducted a comprehensive overview on the current indications for subretinal injection, surgical technique with the available variations, and the potential complications.


Assuntos
Fibrinolíticos , Ativador de Plasminogênio Tecidual , Ativador de Plasminogênio Tecidual/uso terapêutico , Fibrinolíticos/uso terapêutico , Vitrectomia/métodos , Acuidade Visual , Tomografia de Coerência Óptica , Estudos Retrospectivos
15.
Acta Ophthalmol ; 101(7): 815-825, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37493073

RESUMO

PURPOSE: To derive a Delphi method-based consensus for the surgical management of Full Thickness Macular Hole (FTMH) and Lamellar Macular Hole (LMH). METHODS: 37 expert VR surgeons from 21 mainly European countries participated in Delphi method-based questionnaire for diagnosis and treatment of FTMHs and LMHs. RESULTS: A total of 36 items were rated in round 1 by 37 participants, of which 10 items achieved consensus: intraoperative verification of PVD; clinical superiority of OCT-based FTMH classification; practical ineffectiveness of ocriplasmin; circular 360° ILM peeling for small macular holes; use of regular surgical technique for the size of the hole in concomitant retinal detachment; performing complete vitrectomy; SF6 gas as preferred tamponade; cataract surgery if crystalline lens is mildly/moderately opaque; removal of both ILM and LHEP in LMH surgery. In round 2, 18 items with moderate consensus (45-70% agreement) in round 1 were rated by 35 participants. Final consensus was reached in 35% of questions related to both diagnosis and surgical procedures. CONCLUSIONS: This Delphi study provides valuable information about the consensus/disagreement on different scenarios encountered during FTMH and LMH management as a guide tosurgical decision-making. High rate of disagreement and/or variable approaches still exist for treating such relatively common conditions.

16.
Int J Mol Sci ; 24(11)2023 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-37298674

RESUMO

Inherited macular dystrophies refer to a group of degenerative conditions that predominantly affect the macula in the spectrum of inherited retinal dystrophies. Recent trends indicate a clear need for genetic assessment services in tertiary referral hospitals. However, establishing such a service can be a complex task due to the diverse skills required and multiple professionals involved. This review aims to provide comprehensive guidelines to enhance the genetic characterization of patients and improve counselling efficacy by combining updated literature with our own experiences. Through this review, we hope to contribute to the establishment of state-of-the-art genetic counselling services for inherited macular dystrophies.


Assuntos
Macula Lutea , Degeneração Macular , Distrofias Retinianas , Humanos , Aconselhamento Genético , Degeneração Macular/genética , Degeneração Macular/terapia , Distrofias Retinianas/genética , Distrofias Retinianas/terapia
17.
J Clin Med ; 12(10)2023 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-37240481

RESUMO

Age-related macular degeneration (AMD) causes severe vision impairments, including blindness. An option to improve vision in AMD patients is through intraocular lenses and optics. Among others, implantable miniaturized telescopes, which direct light to healthy lateral regions of the retina, can be highly effective in improving vision in AMD patients. Yet, the quality of the restored vision might be sensitive to the optical transmission and aberrations of the telescope. To shed light on these points, we studied the in vitro optical performance of an implantable miniaturized telescope, namely, the SING IMT™ (Samsara Vision Ltd., Far Hills, NJ, USA) designed to improve vision in patients affected by late-stage AMD. Specifically, we measured the optical transmission in the spectral range 350-750 nm of the implantable telescope with a fiber-optic spectrometer. Wavefront aberrations were studied by measuring the wavefront of a laser beam after passing through the telescope and expanding the measured wavefront into a Zernike polynomial basis. Wavefront concavity indicated that the SING IMT™ behaves as a diverging lens with a focal length of -111 mm. The device exhibited even optical transmission in the whole visible spectrum and effective curvature suitable for retinal images magnification with negligible geometrical aberrations. Optical spectrometry and in vitro wavefront analysis provide evidence supporting the feasibility of miniaturized telescopes as high-quality optical elements and a favorable option for AMD visual impairment treatments.

18.
Am J Ophthalmol ; 253: 169-180, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37236521

RESUMO

PURPOSE: To establish consensus among experts in lens and refractive surgery to guide general ophthalmologists on issues related to presbyopia-correcting intraocular lenses (IOLs). DESIGN: A modified Delphi method to reach a consensus among experts. METHODS: A steering committee formulated 105 relevant items grouped into four sections (preoperative considerations, IOL selection, intraoperative considerations, and postoperative considerations). The consensus was defined as ≥ 70% of experts agreeing with the evaluation of a statement. RESULTS: Ten experts participated and completed all rounds of questionnaires (100% response rate). Of 68 items considered in the preoperative considerations, consensus was achieved in 48 (70.6%). There was a lack of consensus over IOL selection, the experts only agreed on the importance of the patient's habits for the optical IOL design selection. Of the 14 considerations related to intraoperative issues, the experts reached a consensus on 10 (71.4%). The postoperative considerations section reached the highest consensus in 10 items of 13 (76.9%). CONCLUSIONS: Key recommendations for a diffractive multifocal IOL were a potential postoperative visual acuity > 0.5, a keratometry between 40-45 diopters, a pupil >2.8 mm under photopic conditions and <6.0 mm under scotopic conditions, a root mean square of higher order corneal aberrations <0.5 µm for 6-mm pupil size, while monofocal or non-diffractive IOLs should be considered for patients with coexisting eye disorders. A lack of agreement was found in the issues related to the IOL selection.


Assuntos
Visão de Cores , Lentes Intraoculares , Presbiopia , Humanos , Presbiopia/cirurgia , Técnica Delphi , Implante de Lente Intraocular , Desenho de Prótese
20.
Transl Vis Sci Technol ; 12(4): 6, 2023 04 03.
Artigo em Inglês | MEDLINE | ID: mdl-37017957

RESUMO

Purpose: To establish a correlation between phacoemulsification tip normalized driving voltage (NDV) and crystalline lens hardness and use it as an objective measure of lens hardness. The study used a phaco tip equipped with previously validated elongation control adjusting the driving voltage (DV) to produce invariant elongation regardless of resistance. Methods: The laboratory study measured the mean and maximum DV of the phaco tip immersed in glycerol-balanced salt solution and correlated the DV with the kinematic viscosity at 25, 50, and 75 µm tip elongation. The NDV were obtained by dividing the DV in glycerol by the DV in the balanced salt solution. The clinical arm of the study recorded DV of 20 consecutive cataract surgeries. The correlation of mean and maximum NDV to Lens Opacities Classification System (LOCS) III classification, patient's age and effective phaco time were evaluated. Results: The mean and maximum NDV correlated with the kinematic viscosity of the glycerol solution (P < 0.001 in all cases). Mean and maximum NDV during cataract surgery correlated with patients' age, effective phaco time, LOCS III nuclear color, and nuclear opalescence (P < 0.001 in all cases). Conclusions: When a feedback algorithm is running, DV variation strictly correlates with encountered resistance in glycerol solutions and real-life surgery. NDV significantly correlates with the LOCS classification. Future developments might include sensing tips that react to lens hardness in real time. Translational Relevance: The study correlates for the first time phaco tip DV and crystalline lens mechanical properties, establishing an objective and reliable measure of lens hardness. This may lead to smart phaco tips reacting to cataract hardness change in real time and sparing ultrasound dispersion.


Assuntos
Catarata , Cristalino , Facoemulsificação , Humanos , Glicerol , Dureza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...