Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pacing Clin Electrophysiol ; 33(9): 1054-62, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20487339

RESUMO

BACKGROUND: Although it has been recently demonstrated that there was no significant difference in total survival and clinical outcomes between patients who underwent coronary artery bypass grafting (CABG) with or without surgical ventricular reconstruction (SVR), the question of whether or not SVR decreases the arrhythmic risk profile in this population has not been clarified yet. OBJECTIVE: To determine the real incidence of sudden cardiac death (SCD) and sustained ventricular tachycardia/ventricular fibrillation (sustained VT/VF) in patients following CABG added to SVR and to define their clinical and echocardiographic parameters predicting in-hospital and long-term arrhythmic events (SCD + sustained VT/VF). METHODS: Pre- and postoperative clinical and echocardiographic values as well as postoperative electrocardiogram Holter data of 65 patients (21 female, 63 ± 11 years) who underwent SVR + CABG were retrospectively evaluated. RESULTS: Mean follow-up was 1,105 ± 940 days. At 3 years, the SCD-free rate was 98% and the rate free from arrhythmic events was 88%. Multivariate logistic analysis identified a preoperative left ventricular end-systolic volume index (LVESVI) > 102 mL/m(2) (odds ratio [OR] 1.4, confidence interval [CI] 1.073-1.864, P = 0.02; sensitivity 100%, specificity 94%) and a postoperative pulmonary artery systolic pressure (PASP) > 27 mmHg (OR 2.3, CI 1.887-4.487, P = 0.01; sensitivity 100%, specificity 71%) as independent predictors of arrhythmic events. CONCLUSIONS: Our and previous studies report a low incidence of arrhythmic events in patients following SVR added to CABG, considering the high-risk profile of the study population. A preoperative LVESVI > 102 mL/m(2) and a postoperative PASP > 27 mmHg had a good sensitivity and specificity in predicting arrhythmic events.


Assuntos
Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária/estatística & dados numéricos , Morte Súbita Cardíaca/epidemiologia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/epidemiologia , Fibrilação Ventricular/epidemiologia , Idoso , Eletrocardiografia Ambulatorial , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
2.
J Ultrasound Med ; 28(9): 1167-74, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19710214

RESUMO

OBJECTIVES: Recently, a new echocardiographic nonflow corrected index (ejection fraction/velocity ratio [EFVR] = percent left ventricular ejection fraction [EF]/maximum aortic gradient) has been introduced and has shown excellent accuracy in quantifying the effective orifice area (EOA) in native aortic valves and bio-prostheses. The objective of this study was to assess the utility of the EFVR to quantify the indexed EOA in patients with an aortic bioprosthesis and left ventricular dysfunction considering an indexed EOA value of 0.85 cm(2)/m(2) or less to be indicative of a prosthesis-patient mismatch (PPM), defined as an EOA of the inserted prosthetic valve of less than that of the normal human valve. METHODS: We studied 100 patients (62 men and 38 women; mean age +/- SD, 71 +/- 8.6 years) with an aortic bioprosthesis and left ventricular dysfunction (EF < or =49%), and we evaluated the indexed EOA by both the continuity equation (CE) and EFVR. RESULTS: We found a significant linear correlation between the CE and EFVR (r = 0.85; P < .0001) and good agreement between the two methods in identifying patients with an indexed EOA of 0.85 cm(2)/m(2) or less; the correlation began to become nonlinear for patients with an indexed EOA of greater than 1.2 cm(2)/m(2), which was not clinically relevant. Notably, all 11 patients with a discrepancy between the indexed EOA and EFVR (ie, EFVR < or =1.0 and indexed EOA >0.85 cm(2)/m(2)) also showed an indexed EOA of greater than 0.85 but less than or equal to 1.0 cm(2)/m(2) (meaning the presence of a mild PPM). CONCLUSIONS: The EFVR can be considered a reliable echocardiographic alternative to the CE, especially in conditions in which that is technically difficult, allowing identification of a PPM (indexed EOA < or =0.85 cm(2)/m(2)) with excellent sensitivity and specificity.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas/efeitos adversos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Idoso , Feminino , Humanos , Masculino , Falha de Prótese , Resultado do Tratamento , Ultrassonografia
3.
J Interv Card Electrophysiol ; 23(3): 247-9, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18810625

RESUMO

We describe a rare case of superior vena cava syndrome that occurred a few hours after insertion of an implantable cardioverter defibrillator through the right subclavian vein in a patient with previous dual chamber DDD pacemaker. The patient was successfully treated with anticoagulant therapy showing a fast clinical and instrumental improvement.


Assuntos
Anticoagulantes/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Síndrome da Veia Cava Superior/tratamento farmacológico , Síndrome da Veia Cava Superior/etiologia , Doença Aguda , Idoso de 80 Anos ou mais , Humanos , Masculino , Síndrome da Veia Cava Superior/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Ital Heart J ; 5(10): 789-92, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15626279

RESUMO

Transient left ventricular apical ballooning, sometimes associated with intraventricular pressure gradient, is a condition simulating an acute myocardial infarction and may occur in patients presenting with chest pain, electrocardiographic changes and minimal myocardial enzyme release typically without coronary angiographic stenosis. It was originally described in the Japanese population and is often associated with cerebrovascular accidents, surgical procedures and emotional and physical stress. We report the case of a 65-year-old woman presenting with chest pain typical of myocardial ischemia, dyspnea, electrocardiographic abnormalities and signs of hemodynamic instability, occurring after a severe emotional stress. Echocardiography and contrast ventriculography showed normokinesis confined to the basal segments of the left ventricle, with a markedly decreased ejection fraction. Scintigraphy was suggestive of a large perfusion defect. The electrocardiographic abnormalities and dyskinesis persisted for many hours. Coronary angiography, performed in the acute phase, was completely normal. Five months later, the functional and electrocardiographic abnormalities had totally disappeared.


Assuntos
Cardiomiopatias/diagnóstico , Infarto do Miocárdio/diagnóstico , Disfunção Ventricular Esquerda/diagnóstico , Pressão Ventricular , Doença Aguda , Idoso , Cardiomiopatias/diagnóstico por imagem , Dor no Peito , Diagnóstico Diferencial , Feminino , Humanos , Estresse Psicológico/complicações , Síndrome , Fatores de Tempo , Ultrassonografia , Disfunção Ventricular Esquerda/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...