1.
J Med Imaging (Bellingham) ; 9(3): 031503, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35155718

RESUMO

Purpose: Surgery is an essential part of the curative plan for most patients affected with solid tumors. The outcome of such surgery, e.g., recurrence rates and ultimately patient survival, depends on several factors where the resection margin is of key importance. Presently, the resection margin is assessed by classical histology, which is time-consuming (several days), destructive, and basically only gives two-dimensional information. Clearly, it would be advantageous if immediate feedback on tumor extension in all three dimensions were available to the surgeon intraoperatively. Approach: We investigate a laboratory propagation-based phase-contrast x-ray computed tomography system that provides the resolution, the contrast, and, potentially, the speed for this purpose. The system relies on a liquid-metal jet microfocus source and a scintillator-coated CMOS detector. Our study is performed on paraffin-embedded non-stained samples of human pancreatic neuroendocrine tumors, liver intrahepatic cholangiocarcinoma, and pancreatic serous cystic neoplasm (benign). Results: We observe tumors with distinct and sharp edges having cellular resolution ( ∼ 10 µ m ) as well as many assisting histological landmarks, allowing for resection margin assessment. All x-ray data are compared with classical histology. The agreement is excellent. Conclusion: We conclude that the method has potential for intraoperative three-dimensional virtual histology.

2.
J Microsc ; 283(1): 29-40, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33822371

RESUMO

Imaging the visual systems of bumblebees and other pollinating insects may increase understanding of their dependence on specific habitats and how they will be affected by climate change. Current high-resolution imaging methods are either limited to two dimensions (light- and electron microscopy) or have limited access (synchrotron radiation x-ray tomography). For x-ray imaging, heavy metal stains are often used to increase contrast. Here, we present micron-resolution imaging of compound eyes of buff-tailed bumblebees (Bombus terrestris) using a table-top x-ray nanotomography (nano-CT) system. By propagation-based phase-contrast imaging, the use of stains was avoided and the microanatomy could more accurately be reconstructed than in samples stained with phosphotungstic acid or osmium tetroxide. The findings in the nano-CT images of the compound eye were confirmed by comparisons with light- and transmission electron microscopy of the same sample and finally, comparisons to synchrotron radiation tomography as well as to a commercial micro-CT system were done.


Assuntos
Laboratórios , Tetróxido de Ósmio , Animais , Abelhas , Microscopia de Contraste de Fase/instrumentação , Síncrotrons , Tomografia Computadorizada por Raios X/métodos , Microtomografia por Raio-X/métodos
3.
Radiology ; 289(3): 670-676, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30251933

RESUMO

Purpose To evaluate phase-contrast CT as a noninvasive alternative to histology in the study of ancient soft tissue. Materials and Methods The imaging was performed between May 8 and June 13, 2017. A mummified human hand from ancient Egypt was imaged in a laboratory phase-contrast CT arrangement with propagation-based imaging. The experimental arrangement for propagation-based imaging included a microfocus x-ray source, a rotation stage for the sample, and an x-ray detector. The mummified hand was imaged in two different modes. First, a CT scan of the whole hand was performed in an overview arrangement. Then, a detailed scan of the tip of the middle finger was performed. With imaging distances tailored for a large magnification and to maximize the phase-contrast signal, the estimated resolution in the final images was 6-9 µm. Results The overview CT allowed identification of the tendons of the hand, as well as identification of arteries and nerves in the dehydrated soft tissue. In the detailed phase-contrast setting, virtual histology of the soft tissues of the fingertip could be performed. Blood vessels in the nail bed and the microanatomy of the bone marrow and hypodermis were imaged, and the layers of the skin could be distinguished. Round structures in the adipose tissue were identified as the remains of adipocytes. Conclusion Laboratory phase-contrast CT enables imaging of the anatomy and microanatomy of mummified soft tissue with sub-10-µm resolution and may serve as a complement or alternative to the classic invasive histologic methods used in soft-tissue paleopathology. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Mãos/anatomia & histologia , Mãos/diagnóstico por imagem , Múmias/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Egito , Humanos , Masculino
4.
Opt Express ; 26(4): 4989-5004, 2018 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-29475342

RESUMO

The current advances in new generation X-ray sources are calling for the development and improvement of high-performance optics. Techniques for high-sensitivity phase sensing and wavefront characterisation, preferably performed at-wavelength, are increasingly required for quality control, optimisation and development of such devices. We here show that the recently proposed unified modulated pattern analysis (UMPA) can be used for these purposes. We characterised two polymer X-ray refractive lenses and quantified the effect of beam damage and shape errors on their refractive properties. Measurements were performed with two different setups for UMPA and validated with conventional X-ray grating interferometry. Due to its adaptability to different setups, the ease of implementation and cost-effectiveness, we expect UMPA to find applications for high-throughput quantitative optics characterisation and wavefront sensing.

5.
Phys Rev Lett ; 118(20): 203903, 2017 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-28581800

RESUMO

We present a method for x-ray phase-contrast imaging and metrology applications based on the sample-induced modulation and subsequent computational demodulation of a random or periodic reference interference pattern. The proposed unified modulated pattern analysis (UMPA) technique is a versatile approach and allows tuning of signal sensitivity, spatial resolution, and scan time. We characterize the method and demonstrate its potential for high-sensitivity, quantitative phase imaging, and metrology to overcome the limitations of existing methods.

6.
Opt Lett ; 41(23): 5490-5493, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27906220

RESUMO

Speckle-based x-ray phase-contrast imaging has drawn increasing interest in recent years as a simple, multimodal, cost-efficient, and laboratory-source adaptable method. We investigate its noise properties to help further optimization on the method and further comparison with other phase-contrast methods. An analytical model for assessing noise in a differential phase signal is adapted from studies on the digital image correlation technique in experimental mechanics and is supported by simulations and experiments. The model indicates that the noise of the differential phase signal from speckle-based imaging has a behavior similar to that of the grating-based method.