Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Radiat Prot Dosimetry ; 126(1-4): 326-32, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17522036

RESUMO

The high-energy neutron response of three passive dosemeters in use at the Los Alamos National Laboratory (LANL) has been investigated using metrology-grade fields. The dosemeters include the LANL Model 8823 TLD badge and the LANL PN3 track etch device. Both are dosemeters of record at LANL. The third device was the Personal Neutron Dosemeter (PND), a superheated emulsion device, manufactured by Bubble Technology Industries, Inc. (BTI). The response of the three dosemeters at neutron energies exceeding 10 MeV was assessed with monoenergetic neutrons at the Physikalisch-Technische Bundesanstalt facility (14.8 and 19 MeV). For the sake of completeness, data collected at lower energies are also included in this study. High-energy quasi-monoenergetic beams produced by the cyclotron facilities at the Université Catholique de Louvain (UCL) and the The Svedberg Laboratory (TSL) were also utilised as part of this study. These measurements were made to better understand and help interpret dosemeter readings obtained by workers at high-energy accelerators, such as the 800 MeV spallation neutron source facility located at the Los Alamos Neutron Science Center (LANSCE).


Assuntos
Nêutrons , Reatores Nucleares , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Laboratórios , New Mexico , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Health Phys ; 86(6): 603-12, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15167123

RESUMO

Conventional neutron rem meters currently in use are based on 1960's technology that relies on a large neutron moderator assembly surrounding a thermal detector to achieve a rem-like response function over a limited energy range. Such rem meters present an ergonomic challenge, being heavy and bulky, and have caused injuries during radiation protection surveys. Another defect of traditional rem meters is a poor high-energy response above 10 MeV, which makes them unsuitable for applications at high-energy accelerator facilities. Proton Recoil Scintillator-Los Alamos (PRESCILA) was developed as a low-weight (2 kg) alternative capable of extended energy response, high sensitivity, and moderate gamma rejection. An array of ZnS(Ag) based scintillators is located inside and around a Lucite light guide, which couples the scintillation light to a sideview bialkali photomultiplier tube. The use of both fast and thermal scintillators allows the energy response function to be optimized for a wide range of operational spectra. The light guide and the borated polyethylene frame provide moderation for the thermal scintillator element. The scintillators represent greatly improved versions of the Hornyak and Stedman designs from the 1950's, and were developed in collaboration with Eljen Technology. The inherent pulse height advantage of proton recoils over electron tracks in the phosphor grains eliminates the need for pulse shape discrimination and makes it possible to use the PRESCILA probe with standard pulse height discrimination provided by off-the-shelf health physics counters. PRESCILA prototype probes have been extensively tested at both Los Alamos and the German Bureau of Standards, Physikalisch-Technische Bundesanstalt. Test results are presented for energy response, directional dependence, linearity, sensitivity, and gamma rejection. Initial field tests have been conducted at Los Alamos and these results are also given. It is concluded that PRESCILA offers a viable, ergonomically superior, alternative to traditional rem meters that is effective for a wide range of neutron fields. The probe is capable of excellent sensitivity (40 counts per minute per microSv h-1 for 241AmBe) and extended energy response to beyond 20 MeV. Directional response is uniform (+/-15%) over a wide range of energies. Response linearity has been characterized to over 20 mSv h-1. Gamma rejection is effective in gamma fields up to 2 mSv h-1. The PRESCILA technology has been commercialized and is now offered under license by Ludlum Measurements, Inc.


Assuntos
Análise de Falha de Equipamento , Nêutrons , Contagem de Cintilação/instrumentação , Desenho de Equipamento , Miniaturização , Doses de Radiação , Radiometria/instrumentação , Radiometria/métodos , Reprodutibilidade dos Testes , Contagem de Cintilação/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...