Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Sleep Med ; 112: 165-172, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37866212

RESUMO

BACKGROUND: Poor sleep and attention deficits are common in COPD. OBJECTIVES: To assess the relationship between self-reported poor sleep and attention deficits in COPD. We also studied the association between self-reported sleep and the attention tests with the objective characteristics of sleep. METHODS: Fifty-nine COPD patients were prospectively studied. Self-reported sleep quality was assessed using the Pittsburgh sleep quality index (PSQI). Objective characteristics of sleep were assessed by actigraphy and polysomnography. Attention was evaluated with the Oxford sleep resistance test (OSLER) and the Psychomotor vigilance test (PVT). RESULTS: 28 (47 %) patients referred poor sleep (PSQI >5). In the OSLER test they showed earlier sleep onset than patients with good sleep, median (Interquartil range): 31.2 min (25.4-40) vs 40 min (28.5-40), p: 0.048. They also spent more time making errors: 4.5 % (0.6-7.6) of total test time vs 0.7 % (0.2-5.3), p: 0.048. In PVT, patients with poor sleep presented a greater dispersion of the reaction time values with a higher value in the slowest 10 % of the reactions, 828 (609-1667) msec. vs 708 (601-993) msec, p: 0.028. No association was found between self-reported poor sleep and objective sleep variables. We found no correlation between OSLER and PVT results and polysomnographic variables except between sleep efficiency and PVT response speed (ß: 0.309, p: 0.018). CONCLUSION: Self-reported poor sleep in COPD is associated with attention deficits. Sleep quality should be included in future studies of this facet of cognition in COPD, as well as to assess its potential usefulness as a therapeutic target.


Assuntos
Desempenho Psicomotor , Doença Pulmonar Obstrutiva Crônica , Humanos , Desempenho Psicomotor/fisiologia , Tempo de Reação/fisiologia , Vigília , Sono , Doença Pulmonar Obstrutiva Crônica/complicações
4.
Sleep Med ; 99: 41-48, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35947888

RESUMO

OBJECTIVE: Early diagnosis of obstructive sleep apnea (OSA) in children is important. The use of a nasal cannula as an airflow sensor during polysomnography has not been evaluated in younger children. The study aims to evaluate the use of nasal cannula in detecting respiratory events in children under three with suspected OSA during daytime nap studies. METHODS: A total of 185 patients were prospectively included. Respiratory events were scored using nasal cannula alone, thermistor alone, and both methods simultaneously as the airflow sensor. Agreement and diagnostic accuracy were assessed. RESULTS: One hundred and seventy-two children were finally analyzed and 110 (64.0%) presented OSA. Total sleep time with an uninterpretable signal was longer with the nasal cannula than with the thermistor (17.8% vs 1.9%; p < 0.001), and was associated with poor sensor tolerance and adenotonsillar hypertrophy. In the estimation of the apnea-hypopnea index, the nasal cannula showed lower agreement than the thermistor with the joint use of the two sensors (intraclass correlation coefficient: 0.79 vs 0.996 with thermistor). Compared with the thermistor, the nasal cannula presented lower sensitivity for detecting OSA (82.7% vs 95.5%) and a lower negative predictive value (76.5% vs 92.4%). Overall, fewer children were diagnosed with severe OSA with the nasal cannula (19.8% vs 30.8% with the thermistor, and 32.6% with both). CONCLUSIONS: In children under the age of three, the ability of the nasal cannula to detect obstructive events was relatively low. Therefore, other non-invasive measurements for identifying respiratory events during sleep may be of additional value.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Cânula , Criança , Humanos , Polissonografia/métodos , Sono , Síndromes da Apneia do Sono/complicações
5.
J Clin Sleep Med ; 18(1): 225-233, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34314351

RESUMO

STUDY OBJECTIVES: In patients treated with noninvasive ventilation, sleep-related breathing changes can modify patient-ventilator interactions, which could reduce its effectiveness. The aim of this prospective observational study was to determine the impact of sleep/wake state on leaks, upper airway obstructive events, and asynchronies in patients treated by long-term noninvasive ventilation. METHODS: Stable patients adapted to noninvasive ventilation were considered for nocturnal polysomnography. Unintentional leaks, upper airway obstructive events, and asynchronies were compared between sleep and awake periods. RESULTS: Twenty-eight patients were enrolled. Underlying diagnoses were neuromuscular disease (n = 11), chest wall disease (n = 8), and obesity-hypoventilation (n = 9). Leaks were more frequent in sleep than in awake periods, with a median of 10% (interquartile range [IQR], 0%-75%) vs 1% (IQR, 0%-9%) of time (P < .001), respectively. During sleep, asynchronies with and without associated leak affected 27% of breaths (IQR, 16%-39%) compared with non-leak-related asynchronies that were recorded in 8% (IQR, 3%-25%) of breaths (P < .001). Asynchronies affecting more than 10% of total breaths were more frequent in sleep (25 patients, 89%) than in awake time (8 patients, 29%; P = .25). Eleven patients (39%) presented with 5 or more upper airway obstructive events without reduction in ventilatory drive per hour of sleep. CONCLUSIONS: In patients adapted to home noninvasive ventilation, leaks, asynchronies, and upper airway obstructive events are frequent during the night and are concentrated in sleep periods. Asynchronies are often associated with leaks. These findings may have clinical implications considering that in patients with low sleep efficiency respiratory events could be underestimated if sleep is not evaluated. CITATION: Martí S, Ferré A, Sampol G, et al. Sleep increases leaks and asynchronies during home noninvasive ventilation: a polysomnographic study. J Clin Sleep Med. 2022;18(1):225-233.


Assuntos
Ventilação não Invasiva , Humanos , Hipoventilação , Polissonografia , Respiração Artificial , Sono
6.
J Clin Med ; 10(2)2021 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-33440893

RESUMO

Sleep apnea, a condition that modifies sleep and circadian rhythms, is highly prevalent in patients with diabetes. However, it is not known if there is an association between sleep apnea, circadian alterations and glycemic regulation in this type of patient. Here, a polysomnographic study was carried out on 21 women and 25 men (mean age = 64.3 ± 1.46 years) with diagnoses of type 2 diabetes to detect the presence of sleep apnea. Moreover, patients wore an actigraph and a temperature sensor on the wrist for one week, to study the manifestation of the circadian rhythms. The correlations of circadian and polysomnographic variables with the severity of apnea, measured by the apnea-hypopnea index, and with glycemic dysregulation, measured by the percentage of glycated hemoglobin, were analyzed. The mean apnea-hypoapnea index of all the participants was 39.6 ± 4.3. Apnea-hypoapnea index correlated with % N1, negatively with % N3, and also the stability of the active circadian rhythm. However, no significant correlation was found between the apnea-hypopnea index and wrist temperature rhythm and glycated hemoglobin. Glycated hemoglobin levels were negatively associated with the percentage of variance explained by the wrist temperature circadian rhythm (calculated via 24 and 12 h rhythms). This association was independent of body mass index and was strongest in patients with severe apnea. In conclusion, patients with diabetes showed altered circadian rhythms associated with a poor glycemic control and this association could partially be related to the coexistence of sleep apnea.

7.
J Clin Sleep Med ; 16(2): 243-250, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31992414

RESUMO

STUDY OBJECTIVES: The objective of this study was to determine which respiratory and architectural sleep parameters are related to cognitive function and cognitive status (mild cognitive impairment [MCI] versus normal cognitive aging [NCA]) in community-dwelling individuals with hypertension. Additionally, it aimed to determine whether the results changed in the presence or absence of vascular brain lesions (silent brain infarcts and extensive white matter hyperintensities [WMHs]). METHODS: In a cohort of individuals with hypertension and without previous stroke or dementia, we conducted in-hospital polysomnography including electroencephalography, electro-oculography, electromyography, and magnetic resonance imaging to assess silent brain infarcts and WMHs. Cognitive testing was carried out with a screening test (Dementia Rating Scale version 2 [DRS-2]) and a complete cognitive visit. RESULTS: This study included 158 participants with a median age of 65.0 years; 32.3% were females, and the median apnea-hypopnea index was 22.3 events/h. MCI was diagnosed in 24 study participants, and the rest had NCA. Regarding respiratory parameters, total DRS-2 scores (ß; 95% CI) 0.121; 0.026, 0.215 were positively associated with mean O2 saturation, whereas total (-0.022; -0.036, -0.009), executive function (-0.016; -0.026, -0.006) and memory (-0.017; -0.029, -0.004) DRS-2 scores were all negatively associated with the percent of time with oxygen saturation < 90% after correcting for education, vascular risk factors, and magnetic resonance imaging lesions. Regarding sleep architecture, Attention DRS-2 scores (0.0153; 0.001, 0.306) were independently associated with total sleep time. Similar results were obtained in the absence of silent brain infarcts or WMHs in the stratified analysis. None of the sleep parameters were associated with cognitive status. CONCLUSIONS: Low oxygen saturation contributes to cognitive performance, and this effect appears even in the absence of vascular brain lesions in individuals with hypertension.


Assuntos
Função Executiva , Hipertensão , Idoso , Cognição , Feminino , Humanos , Hipertensão/complicações , Hipóxia , Vida Independente , Imageamento por Ressonância Magnética , Masculino , Testes Neuropsicológicos
8.
J Clin Sleep Med ; 15(1): 89-99, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30621833

RESUMO

STUDY OBJECTIVES: The aim of this study is to generate and validate supervised machine learning algorithms to detect patients with Chiari malformation (CM) 1 or 1.5 at high risk of the development of sleep-related breathing disorders (SRBD) using clinical and neuroradiological parameters. METHODS: We prospectively included two independent datasets. A training dataset (n = 90) was used to obtain the best model, whereas a second dataset was used to validate it (n = 74). In both cohorts, the same clinical, neuroradiological, and sleep studies were carried out. We used two supervised machine learning approaches, multiple logistic regression (MLR) and the unbiased recursive partitioning technique conditional inference tree (URP-CTREE), to detect patients at high risk of SRBD. We then compared the accuracy, sensitivity, and specificity of the two prediction models. RESULTS: Age (odds ratio [OR] 1.1 95% confidence interval [CI] 1.05-1.17), sex (OR 0.19 95% CI 0.05-0.67), CM type (OR 4.36 95% CI 1.14-18.5), and clivus length (OR 1.14 95% CI 1.01-1.31) were the significant predictor variables for a respiratory disturbance index (RDI) cutoff that was ≥ 10 events/h using MLR. The URP-CTREE model predicted that patients with CM-1 who were age 52 years or older and males with CM-1 who were older than 29 years had a high risk of SRBD. The accuracy of predicting patients with an RDI ≥ 10 events/h was similar in the two cohorts but in the URP-CTREE model, specificity was significantly greater when compared to MLR in both study groups. CONCLUSIONS: Both MLR and URP-CTREE predictive models are useful for the diagnosis of SRBD in patients with CM. However, URP-CTREE is easier to apply and interpret in clinical practice.


Assuntos
Malformação de Arnold-Chiari/complicações , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Adolescente , Adulto , Idoso , Algoritmos , Feminino , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Polissonografia/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
9.
Parkinsons Dis ; 2018: 8691495, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30515291

RESUMO

BACKGROUND: Sleep problems in patients with advanced Parkinson's disease (PD) have a deleterious impact on quality of life. OBJECTIVE: To assess the effect of levodopa-carbidopa intestinal gel (LCIG) infusion on sleep quality in advanced PD patients. METHODS: Seven patients participated in a prospective pilot study. Before and after 6 months of LCIG infusion, an overnight polysomnography was performed and the Epworth Sleepiness Scale, fatigue scale, Pittsburgh Sleep Quality Index, Beck Depression Inventory, and the Hamilton Anxiety Rating Scale were administered. RESULTS: PSG showed low sleep efficiency. REM sleep without atony was found in 5 patients. After 6 months of LCIG infusion, the percentage of REM sleep decreased as well as the number of arousals especially due to reduction of spontaneous arousals and periodic leg movements during REM sleep, but differences were not statistically significant. Also, scores of all study questionnaires showed a tendency to improve. CONCLUSION: The results show a trend toward an improvement of sleep quality after 6 months of LCIG infusion, although differences as compared to pretreatment values were not statistically significant. The sleep architecture was not modified by LCIG. Further studies with larger study samples are needed to confirm these preliminary findings.

10.
J Sleep Res ; 27(6): e12703, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29770505

RESUMO

Non-restorative sleep is a hallmark symptom of chronic fatigue syndrome/myalgic encephalomyelitis. However, little is known about self-reported sleep disturbances in these subjects. This study aimed to assess the self-reported sleep quality and its impact on quality of life in a Spanish community-based chronic fatigue syndrome/myalgic encephalomyelitis cohort. A prospective cross-sectional cohort study was conducted in 1,455 Spanish chronic fatigue syndrome/myalgic encephalomyelitis patients. Sleep quality, fatigue, pain, functional capacity impairment, psychopathological status, anxiety/depression and health-related quality of life were assessed using validated subjective measures. The frequencies of muscular, cognitive, neurological, autonomic and immunological symptom clusters were above 80%. High scores were recorded for pain, fatigue, psychopathological status, anxiety/depression, and low scores for functional capacity and quality of life, all of which correlated significantly (all p < 0.01) with quality of sleep as measured by the Pittsburgh Sleep Quality Index. Multivariate regression analysis showed that after adjusting for age and gender, the pain intensity (odds ratio, 1.11; p <0.05), psychopathological status (odds ratio, 1.85; p < 0.001), fibromyalgia (odds ratio, 1.39; p < 0.05), severe autonomic dysfunction (odds ratio, 1.72; p < 0.05), poor functional capacity (odds ratio, 0.98; p < 0.05) and quality of life (odds ratio, 0.96; both p < 0.001) were significantly associated with poor sleep quality. These findings suggest that this large chronic fatigue syndrome/myalgic encephalomyelitis sample presents poor sleep quality, as assessed by the Pittsburgh Sleep Quality Index, and that this poor sleep quality is associated with many aspects of quality of life.


Assuntos
Síndrome de Fadiga Crônica/epidemiologia , Síndrome de Fadiga Crônica/psicologia , Qualidade de Vida/psicologia , Autorrelato , Transtornos do Sono-Vigília/epidemiologia , Transtornos do Sono-Vigília/psicologia , Adulto , Estudos de Coortes , Estudos Transversais , Depressão/diagnóstico , Depressão/epidemiologia , Depressão/psicologia , Síndrome de Fadiga Crônica/diagnóstico , Feminino , Inquéritos Epidemiológicos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Autorrelato/normas , Sono/fisiologia , Transtornos do Sono-Vigília/diagnóstico , Adulto Jovem
11.
J Sleep Res ; 27(5): e12640, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29171110

RESUMO

Previous studies have estimated an overall prevalence for narcolepsy between 15 and 70 cases per 100 000 inhabitants. We aimed to estimate the prevalence of narcolepsy in Catalunya (Catalonia), a north-east region of Spain (7 424 754 inhabitants), on 31 December 2014 by identifying all living subjects diagnosed with narcolepsy. First, we identified patients diagnosed by one of the 13 sleep, paediatric or neurological departments that perform tests regularly to diagnose narcolepsy. In a second phase, we searched for additional patients with narcolepsy in a clinical database of the primary health-care system. Clinical files were reviewed and narcolepsy diagnosis validated according to the Brighton Collaboration case definitions. Three hundred and twenty-five patients had a validated diagnosis of narcolepsy in the specialized centres (mean age: 44.6 years, range: 6-89; male: 60.3%; 85% with narcolepsy type 1), including 17.8% cases in Brighton, definition level 1, 62.5% in level 2, 15.4% in level 3 and 4.3% in level 4a. The overall prevalence for narcolepsy was 4.4; 3.7 for narcolepsy type 1 and 0.7 cases per 100 000 inhabitants for narcolepsy type 2. Fifty-six additional narcoleptic patients were identified in the primary health-care system, increasing the overall prevalence to 5.2 cases per 100 000 inhabitants. Prevalence rates for narcolepsy type 1 increased from childhood to adulthood, but in subjects aged more than 50 years there was a substantial drop in prevalence rates, suggesting the presence of a significant pool of undiagnosed cases in this population. Narcolepsy can be considered a rare neurological disorder in Catalunya.


Assuntos
Narcolepsia/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Espanha , Adulto Jovem
12.
J Sleep Res ; 27(2): 232-239, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28631309

RESUMO

Obstructive sleep apnea syndrome is very prevalent in hypertensive subjects. Moreover, obstructive sleep apnea syndrome activates multiple processes that might be associated with silent cerebral infarct independently of established risk factors. Our aim is to estimate the frequency of obstructive sleep apnea syndrome in hypertensive patients with and without silent cerebral infarct, and to determine whether obstructive sleep apnea syndrome is an independent risk factor of silent cerebral infarct and/or lacunar silent cerebral infarct in patients with hypertension. In this matched cross-sectional study performed in hypertensive subjects, each patient with silent cerebral infarct detected by magnetic resonance imaging was matched with two patients without silent cerebral infarct. Polysomnographic studies were performed, and the apnea-hypopnea index was calculated. Severe obstructive sleep apnea syndrome was considered in those with apnea-hypopnea index >30. One-hundred and eighty-three patients, 61 with silent cerebral infarct and 122 without silent cerebral infarct, were evaluated. The mean age was 64.1 ± 4.5 years, and 72.1% were men. The frequency of severe obstructive sleep apnea syndrome was 44.3% in patients with silent cerebral infarct and 38.5% in the control group. An adjusted conditional logistic regression model did not show a significant increased risk of silent cerebral infarct in patients with severe obstructive sleep apnea syndrome (odds ratio 1.362; 95% confidence interval: 0.659-2.813; P = 0.404). Forty-three patients (70.5%) of the silent cerebral infarct were lacunar. The presence of severe obstructive sleep apnea syndrome was significantly higher in lacunar silent cerebral infarct when compared with patients without lacunar infarcts (55.8% versus 35.7%, P = 0.019), being independently associated on an adjusted logistic regression model (odds ratio 2.177; 95% confidence interval: 1.058-4.479; P = 0.035). In conclusion, severe obstructive sleep apnea syndrome is highly prevalent among hypertensive subjects, and is independently associated with lacunar silent cerebral infarct.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/epidemiologia , Hipertensão/diagnóstico por imagem , Hipertensão/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico por imagem , Apneia Obstrutiva do Sono/epidemiologia , Idoso , Infarto Cerebral/fisiopatologia , Estudos Transversais , Feminino , Humanos , Hipertensão/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Apneia Obstrutiva do Sono/fisiopatologia , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/fisiopatologia
13.
Thorax ; 73(4): 361-368, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29146865

RESUMO

RATIONALE: Despite a significant association between obesity hypoventilation syndrome (OHS) and cardiac dysfunction, no randomised trials have assessed the impact of non-invasive ventilation (NIV) or CPAP on cardiac structure and function assessed by echocardiography. OBJECTIVES: We performed a secondary analysis of the data from the largest multicentre randomised controlled trial of OHS (Pickwick project, n=221) to determine the comparative efficacy of 2 months of NIV (n=71), CPAP (n=80) and lifestyle modification (control group, n=70) on structural and functional echocardiographic changes. METHODS: Conventional transthoracic two-dimensional and Doppler echocardiograms were obtained at baseline and after 2 months. Echocardiographers at each site were blinded to the treatment arms. Statistical analysis was performed using intention-to-treat analysis. RESULTS: At baseline, 55% of patients had pulmonary hypertension and 51% had evidence of left ventricular hypertrophy. Treatment with NIV, but not CPAP, lowered systolic pulmonary artery pressure (-3.4 mm Hg, 95% CI -5.3 to -1.5; adjusted P=0.025 vs control and P=0.033 vs CPAP). The degree of improvement in systolic pulmonary artery pressure was greater in patients treated with NIV who had pulmonary hypertension at baseline (-6.4 mm Hg, 95% CI -9 to -3.8). Only NIV therapy decreased left ventricular hypertrophy with a significant reduction in left ventricular mass index (-5.7 g/m2; 95% CI -11.0 to -4.4). After adjusted analysis, NIV was superior to control group in improving left ventricular mass index (P=0.015). Only treatment with NIV led to a significant improvement in 6 min walk distance (32 m; 95% CI 19 to 46). CONCLUSION: In patients with OHS, medium-term treatment with NIV is more effective than CPAP and lifestyle modification in improving pulmonary hypertension, left ventricular hypertrophy and functional outcomes. Long-term studies are needed to confirm these results. TRIAL REGISTRATION NUMBER: Pre-results, NCT01405976 (https://clinicaltrials.gov/).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Ecocardiografia Doppler , Ventilação não Invasiva , Síndrome de Hipoventilação por Obesidade/diagnóstico , Síndrome de Hipoventilação por Obesidade/terapia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Humanos , Estilo de Vida , Masculino , Pessoa de Meia-Idade , Ventilação não Invasiva/métodos , Síndrome de Hipoventilação por Obesidade/fisiopatologia , Polissonografia/métodos , Qualidade de Vida , Espanha , Espirometria , Resultado do Tratamento
14.
Brain Behav ; 7(8): e00758, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28828219

RESUMO

INTRODUCTION: Levodopa-carbidopa intestinal gel (LCIG) infusion has demonstrated to improve motor fluctuations. The aim of this study is to assess the long-term safety and effectiveness of LCIG infusion in advanced Parkinson's disease (PD) patients with motor fluctuations and its effect in nonmotor symptoms. METHODS: Adverse events (AE) and their management, clinical motor, and nonmotor aspects were assessed up to 10 years. Thirty-seven patients were treated with LGIC; in three subsets of patients, specific batteries of tests were used to assess cognitive and behavior assessment for 6 months, quality of sleep for 6 months, and quality of life and caregiver burden for 1 year. RESULTS: There was a high number of AE, but manageable, most of mild and moderate severity. All patients experienced significant improvement in motor fluctuations with a reduction in mean daily off time of 4.87 hr after 3 months (n = 37) to 6.25 hr after 9 years (n = 2). Diskynesias remained stables in 28 patients (75.7%) and improved in 5 patients (13.5%). There was no neuropsychological deterioration, but an improvement in attentional functions, voluntary motor control, and semantic fluency. Quality of sleep did not worsen, and there was an improvement in the subjective parameters, although overnight polysomnography did not change. There was a significant sustained improvement of 37% in PD-Q39 after 3 months and to 1 year, and a significant reduction in caregiver burden of 10% after 3 months. CONCLUSION: LCIG infusion is a safe and efficacious treatment for the control of motor fluctuations, and for improvement or nonworsening of nonmotor aspects, long-term sustained, and feasible for use in routine care.


Assuntos
Carbidopa , Levodopa , Doença de Parkinson , Qualidade de Vida , Idoso , Antiparkinsonianos/administração & dosagem , Antiparkinsonianos/efeitos adversos , Antiparkinsonianos/farmacocinética , Carbidopa/administração & dosagem , Carbidopa/efeitos adversos , Carbidopa/farmacocinética , Vias de Administração de Medicamentos , Combinação de Medicamentos , Monitoramento de Medicamentos/métodos , Feminino , Géis , Humanos , Absorção Intestinal , Levodopa/administração & dosagem , Levodopa/efeitos adversos , Levodopa/farmacocinética , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Doença de Parkinson/diagnóstico , Doença de Parkinson/tratamento farmacológico , Doença de Parkinson/fisiopatologia , Doença de Parkinson/psicologia , Estudos Prospectivos , Espanha , Tempo , Resultado do Tratamento
15.
Sleep ; 40(6)2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28453783

RESUMO

Study objective: The aim of the present study is to describe the prevalence of sleep disorders in a large group of patients with Chiari malformation type 1 (CM-1) and determine the presence of risk factors associated with these abnormalities. Methods: Prospective study with consecutive patient selection. We included 90 adult patients with CM-1, defined by the presence of a cerebellar tonsillar descent (TD) ≥3 mm. Clinical, neuroradiological studies, and nocturnal polysomnography (PSG) was carried out. In addition, patients were also subclassified into 2 CM subtypes: CM-1, with the obex above the foramen magnum (FM) and CM-1.5, in which along with a TD ≥3 mm, the obex was located below the FM. Results: We observed a high prevalence (50%) of sleep-related breathing disorders (SRBDs) with predominant hypopnea. Only six patients showed a central apnea index of ≥5. Hypoventilation was observed in only three patients. SRBD severity was associated with male sex, older age, excess weight, and the presence of hydrocephalus. No differences in clinical or PSG parameters were found when comparing CM subtypes (CM-1 and CM-1.5). Sleep architecture study showed decreased sleep efficiency with an increase in arousal and waking after sleep onset. The presence of SRBDs was found to be associated with poorer sleep architecture parameters. Conclusions: This study confirms a high prevalence of SRBDs in patients with CM-1 and CM-1.5, with a predominant obstructive component. Nocturnal PSG recordings should be systematically conducted in these patients, especially those who are male, older, or overweight or those who present hydrocephalus.


Assuntos
Malformação de Arnold-Chiari/epidemiologia , Dissonias/epidemiologia , Dissonias/fisiopatologia , Adulto , Distribuição por Idade , Malformação de Arnold-Chiari/classificação , Nível de Alerta , Feminino , Humanos , Hidrocefalia/epidemiologia , Hipoventilação/epidemiologia , Masculino , Sobrepeso/epidemiologia , Polissonografia , Prevalência , Estudos Prospectivos , Fatores de Risco , Caracteres Sexuais , Síndromes da Apneia do Sono/epidemiologia , Síndromes da Apneia do Sono/fisiopatologia , Vigília
16.
Epilepsy Behav Case Rep ; 7: 13-15, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28066710

RESUMO

This prospective uncontrolled study evaluated the effect of low-dose adjunctive perampanel therapy (4 mg/day for 3 months) on the sleep-wake cycle and daytime somnolence in adult patients (n = 10) with focal seizures. A > 50% reduction in the number of seizures was reported in 80% of the study patients; treatment had no significant effect on any sleep parameters as evident by the Maintenance of Wakefulness Test, Pittsburgh Sleep Quality Index and Epworth Sleepiness Scale scores. Two patients reported dizziness with treatment. In conclusion, low-dose perampanel may improve seizure control without affecting the sleep characteristics or daytime somnolence in patients with epilepsy.

17.
PLoS One ; 11(6): e0157579, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27315083

RESUMO

ABSTRACT: Type 2 diabetes (T2D) is an independent risk factor for sleep breathing disorders. However, it is unknown whether T2D affects daily somnolence and quality of sleep independently of the impairment of polysomnographic parameters. MATERIAL AND METHODS: A case-control study including 413 patients with T2D and 413 non-diabetic subjects, matched by age, gender, BMI, and waist and neck circumferences. A polysomnography was performed and daytime sleepiness was evaluated using the Epworth Sleepiness Scale (ESS). In addition, 135 subjects with T2D and 45 controls matched by the same previous parameters were also evaluated through the Pittsburgh Sleep Quality Index (PSQI) to calculate sleep quality. RESULTS: Daytime sleepiness was higher in T2D than in control subjects (p = 0.003), with 23.9% of subjects presenting an excessive daytime sleepiness (ESS>10). Patients with fasting plasma glucose (FPG ≥13.1 mmol/l) were identified as the group with a higher risk associated with an ESS>10 (OR 3.9, 95% CI 1.8-7.9, p = 0.0003). A stepwise regression analyses showed that the presence of T2D, baseline glucose levels and gender but not polysomnographic parameters (i.e apnea-hyoapnea index or sleeping time spent with oxigen saturation lower than 90%) independently predicted the ESS score. In addition, subjects with T2D showed higher sleep disturbances [PSQI: 7.0 (1.0-18.0) vs. 4 (0.0-12.0), p<0.001]. CONCLUSION: The presence of T2D and high levels of FPG are independent risk factors for daytime sleepiness and adversely affect sleep quality. Prospective studies addressed to demonstrate whether glycemia optimization could improve the sleep quality in T2D patients seem warranted.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Síndromes da Apneia do Sono/fisiopatologia , Distúrbios do Início e da Manutenção do Sono/fisiopatologia , Sono/fisiologia , Idoso , Glicemia , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Fatores de Risco , Síndromes da Apneia do Sono/sangue , Síndromes da Apneia do Sono/complicações , Distúrbios do Início e da Manutenção do Sono/sangue , Distúrbios do Início e da Manutenção do Sono/complicações , Fases do Sono/fisiologia , Inquéritos e Questionários
18.
PLoS One ; 10(3): e0119073, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25760760

RESUMO

BACKGROUND: Although sleep apnea-hypopnea syndrome (SAHS) is highly prevalent in patients with type 2 diabetes (T2D), it is unknown whether or not subjects with and without T2D share the same sleep breathing pattern. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study in patients with SAHS according to the presence (n = 132) or not (n = 264) of T2D. Both groups were matched by age, gender, BMI, and waist and neck circumferences. A subgroup of 125 subjects was also matched by AHI. The exclusion criteria included chronic respiratory disease, alcohol abuse, use of sedatives, and heart failure. A higher apnea hypopnea index (AHI) was observed in T2D patients [32.2 (10.2-114.0) vs. 25.6 (10.2-123.4) events/hours; p = 0.002). When sleep events were evaluated separately, patients with T2D showed a significant increase in apnea events [8.4 (0.1-87.7) vs. 6.3 (0.0-105.6) e/h; p = 0.044), as well as a two-fold increase in the percentage of time spent with oxygen saturation <90% [15.7 (0.0-97.0) vs. 7.9 (0.0-95.6) %; <0.001)], higher rates of oxygen desaturation events, and also higher daily sleepiness [7.0 (0.0-21.0) vs. 5.0 (0.0-21.0); p = 0.006)] than subjects without T2D. Significant positive correlations between fasting plasma glucose and AHI, the apnea events, and CT90 were observed. Finally, multiple linear regression analyses showed that T2D was independently associated with AHI (R2 = 0.217), the apnea index (R2 = 0.194), CT90 (R2 = 0.222), and desaturation events. CONCLUSIONS/SIGNIFICANCE: T2D patients present a different pattern of sleep breathing than subject without diabetes. The most important differences are the severity of hypoxemia and the number of apneas whereas the incidence of hypopnea episodes is similar.


Assuntos
Diabetes Mellitus Tipo 2/complicações , Síndromes da Apneia do Sono/etiologia , Adulto , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Fatores de Risco
19.
J Hypertens ; 32(8): 1650-7; discussion 1657, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24879492

RESUMO

OBJECTIVE: The high prevalence of obstructive sleep apnea in patients with resistant hypertension could be mediated by an activation of the renin-angiotensin-aldosterone system. This study assessed the impact of continuous positive airway pressure (CPAP) treatment on plasma aldosterone concentration (PAC). METHODS: One hundred and twenty-four patients with resistant hypertension were assessed, and those who fulfilled inclusion criteria (n = 116) underwent full night polysomnography, 24-h ambulatory blood pressure monitoring, and PAC measurement. Patients with an apnea-hypopnea index above 15 (n = 102) were randomized to CPAP (n = 50) or to conventional treatment (n = 52) for 3 months. RESULTS: Seventy-eight patients completed the follow-up (36 CPAP, 42 conventional treatment); 58 had true resistant hypertension (74.3%), whereas 20 had white-coat resistant hypertension (25.6%). Most patients were men (70.7%), age 58.3 ±â€Š9.4 years, and the mean apnea-hypopnea index was 50.1 ±â€Š21.6. In patients with true resistant hypertension, CPAP achieved a significant decrease in most 24-h BP measurements and a nonsignificant decrease in PAC (25 ±â€Š8.7 vs. 22.7 ±â€Š9 ng/dl; P < 0.182). In patients with white-coat resistant hypertension, CPAP achieved a significant decrease in PAC (26.1 ±â€Š11.2 vs. 18.9 ±â€Š10.1 ng/dl; P < 0.041) and in night-time DBP. After adjustment, a weak but significant association was found between cumulative time spent with SaO2 below 90% (CT90%) and baseline PAC (P < 0.047, R 0.019), and between changes in PAC and changes in office DBP (P < 0.020, R 0.083) CONCLUSIONS:: Night-time hypoxemia and changes in DBP showed an association with baseline and changes in PAC, respectively. CPAP achieved a significant reduction in PAC only in patients with white-coat resistant hypertension, although the CPAP effect on BP was highest in patients with true resistant hypertension.


Assuntos
Aldosterona/sangue , Pressão Positiva Contínua nas Vias Aéreas , Hipertensão/sangue , Apneia Obstrutiva do Sono/sangue , Idoso , Pressão Sanguínea , Resistência a Medicamentos , Feminino , Humanos , Hipertensão/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Renina/sangue
20.
J Clin Sleep Med ; 8(2): 163-8, 2012 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-22505861

RESUMO

STUDY OBJECTIVE: Our objective was to evaluate a portable device (Somté, Compumedics, Australia), which incorporates 2 neurophysiological channels (electroencephalography and electrooculography) with cardiorespiratory monitoring for the diagnosis of obstructive sleep apnea (OSA). METHOD: Full polysomnography (PSG) and Somté recordings were simultaneously performed in 68 patients with suspected OSA. Data were analyzed blindly by 2 scorers. RESULTS: A good agreement between methods in sleep efficiency was observed (68.8% [18.4] with PSG vs 68% [19.1] with Somté [p: n.s.] for scorer 1, and 67.5% [19.1] vs 68.4% [18.5; p: n.s.] for scorer 2). The apnea-hypopnea index (AHI) obtained with Somté was lower than with PSG: 19 (17.8) vs 21.7 (19) (p < 0.001) for scorer 1, and 16.6 (16.7) vs 20 (18.8) (p < 0.001) for scorer 2. The sensitivity of Somté for a PSG-AHI > 5 was 91% for scorer 1 and 90% for scorer 2, while specificity was 77% and 90%, respectively. The areas under the receiver operating curve for different PSG-AHI cutoff points (≥ 5, ≥ 15, and ≥ 30) were 0.81, 0.90, and 0.86, respectively, for scorer 1, and 0.90, 0.88, and 0.83 for scorer 2. CONCLUSIONS: These data suggest that Somté is an effective device to identify sleep and respiratory variables in patients with suspected OSA.


Assuntos
Polissonografia/instrumentação , Apneia Obstrutiva do Sono/diagnóstico , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Eletroculografia/instrumentação , Eletroculografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Fenômenos Fisiológicos Respiratórios , Sensibilidade e Especificidade , Apneia Obstrutiva do Sono/fisiopatologia , Fases do Sono/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...