Traditional Chinese medicine is increasingly used to treat cancer. Our clinical experiences identify Hedyotis diffusa plus Scutellaria barbata as the most common herb-pair (couplet medicinal) used for the core treatment of bladder cancer. This study aims to investigate the antitumor effect of the herb-pair in bladder cancer cells. The results show that Hedyotis diffusa plus Scutellaria barbata inhibited bladder cancer cell growth and clone formation in a dose-dependent and time-dependent manner. It also induced cell apoptosis through decreasing Akt activation and reducing the expression of antiapoptotic proteins Bcl-2 and Mcl-1. Further experiments showed that miR-155 was reduced by the herb-pair and miRNA-155 inhibitor induced cell apoptosis and suppressed Akt activation. Overexpression of miR-155 reversed herb-pair induced cell apoptosis through activating Akt pathway in both bladder cancer cell lines. The findings reveal that Hedyotis diffusa plus Scutellaria barbata reduce Akt activation through reducing miR-155 expression, resulting in cell apoptosis. It demonstrated the potential mechanism of Hedyotis diffusa plus Scutellaria barbata for the core treatment of bladder cancer.

2.
Electrophoresis ; 34(20-21): 2962-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24037989

RESUMO

Optimization based on central composite design (CCD) for enantioseparation of anisodamine (AN), atenolol (AT), and metoprolol (ME) in human urine was developed using a microfluidic chip-CE device. Coupling the flexible and wide working range of microfluidic chip-CE device to CCD for chiral separation of AN, AT, and ME in human urine, a total of 15 experiments is needed for the optimization procedure as compared to 75 experiments using the normal one variable at a time optimization. The optimum conditions obtained are found to be more robust as shown by the curvature effects of the interaction factors. The developed microfluidic chip-CE-ECL system with adjustable dilution ratios has been validated by satisfactory recoveries (89.5-99% for six enanotiomers) in urine sample analysis. The working range (0.3-600 µM), repeatability (3.1-4.9% RSD for peak height and 4.0-5.2% RSD for peak area), and detection limit (0.3-0.6 µM) of the method developed are found to meet the requirements for bedside monitoring of AN, AT, and ME in patients under critical conditions. In summary, the hyphenation of CCD with the microfluidic chip-CE device is shown to offer a rapid means for optimizing the working conditions on simultaneous separation of three racemic drugs using the microfluidic chip-CE device developed.


Assuntos
Antiarrítmicos/urina , Atenolol/urina , Eletroforese em Microchip/instrumentação , Metoprolol/urina , Alcaloides de Solanáceas/urina , Antiarrítmicos/isolamento & purificação , Atenolol/isolamento & purificação , Desenho de Equipamento , Humanos , Limite de Detecção , Medições Luminescentes/instrumentação , Metoprolol/isolamento & purificação , Reprodutibilidade dos Testes , Alcaloides de Solanáceas/isolamento & purificação , Estereoisomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...