Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 15(5): 1320-8, 2015 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-25589423

RESUMO

This paper presents a continuous-flow microfluidic device for sorting stem cells and their differentiation progenies. The principle of the device is based on the accumulation of multiple dielectrophoresis (DEP) forces to deflect cells laterally in conjunction with the alternating on/off electric field to manipulate the cell trajectories. The microfluidic device containing a large array of oblique interdigitated electrodes was fabricated using a combination of standard and soft lithography techniques to generate a PDMS-gold electrode construct. Experimental testing with human mesenchymal stem cells (hMSC) and their differentiation progenies (osteoblasts) was carried out at different flow rates, and clear separation of the two populations was achieved. Most of the osteoblasts experiencing stronger DEP forces were deflected laterally and continuously, following zig-zag trajectories, and moved towards the desired collection outlet, whereas most of the hMSCs remained on the original trajectory due to weaker DEP forces. The experimental measurements were characterized and evaluated quantitatively, and consistent performance was demonstrated. Collection efficiency up to 92% and 67% for hMSCs and osteoblasts, respectively, along with purity up to 84% and 87% was obtained. The experimental results established the feasibility of our microfluidic DEP sorting device for continuous, label-free sorting of stem cells and their differentiation progenies.


Assuntos
Separação Celular/métodos , Eletroforese , Células-Tronco Mesenquimais/citologia , Técnicas Analíticas Microfluídicas/métodos , Diferenciação Celular , Separação Celular/instrumentação , Desenho de Equipamento , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Osteoblastos/citologia
2.
Lab Chip ; 13(12): 2300-10, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23636706

RESUMO

This paper presents a microfluidic electrical impedance flow cytometer (FC) for identifying the differentiation state of single stem cells. This device is comprised of a novel dual micropore design, which not only enhances the processing throughput, but also allows the associated electrodes to be used as a reference for one another. A signal processing algorithm, based on the support vector machine (SVM) theory, and a data classification method were developed to automate the identification of sample types and cell differentiation state based on measured impedance values. The device itself was fabricated using a combination of standard and soft lithography techniques to generate a PDMS-gold electrode construct. Experimental testing with non-biological particles and mouse embryonic carcinoma cells (P19, undifferentiated and differentiated) was carried out using a range of excitation frequencies. The effects of the frequency and the interrogation parameters on sample identification performance were investigated. It was found that the real and imaginary part of the detected impedance signal were adequate for distinguishing the undifferentiated P19 cells from non-biological polystyrene beads at all tested frequencies. A higher frequency and an opacity index were required to resolve the undifferentiated and differentiated P19 cells by capturing capacitive changes in electrophysiological properties arising from differentiation. The experimental results demonstrated salient accuracy of the device and algorithm, and established its feasibility for non-invasive, label-free identification of the differentiation state of the stem cells.


Assuntos
Técnicas Analíticas Microfluídicas/métodos , Células-Tronco Neoplásicas/citologia , Animais , Diferenciação Celular , Dimetilpolisiloxanos/química , Eletrodos , Citometria de Fluxo , Ouro/química , Camundongos , Técnicas Analíticas Microfluídicas/instrumentação , Poliestirenos/química , Máquina de Vetores de Suporte
3.
Cardiovasc Eng Technol ; 3(2): 237-247, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22844388

RESUMO

The development of adjunctive therapies which attenuate adverse remodeling and improve LV function post myocardial infarction (MI) is of significant clinical interest. Previously, we have shown that targeted delivery of therapeutic vascular endothelial growth factor (VEGF) to the infarct border zone significantly increases vascular perfusion and results in improvements in LV function. In this study, we tested the hypothesis that improvements in cardiac function observed with this novel targeted drug delivery system strongly correlate with reductions in collagen deposition in the scar tissue after an MI. Rats received anti-P-selectin conjugated immunoliposomes containing VEGF immediately post-MI. Over 4 weeks, evolutionary changes in LV geometry and function were correlated with collagen deposition and infarct size quantified by Gomori's trichrome and picrosirius red staining. Targeted VEGF treated hearts showed a 37% decrease in collagen deposition in the anterior wall, as well as significant improvements in LV filling pressures. Multi-regression analysis showed that the extent of collagen deposition post MI can be predicted by a linear combination of normalized LV mass and ejection fraction. Targeted delivery of VEGF post-MI results in significant decreases in collagen deposition and adverse remodeling. Improvements in cardiac function in this model are related to degree of collagen deposition and extent of scar formation.

4.
J Biomed Opt ; 17(5): 056014, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22612137

RESUMO

Myocardial infarction often leads to an increase in deposition of fibrillar collagen. Detection and characterization of this cardiac fibrosis is of great interest to investigators and clinicians. Motivated by the significant limitations of conventional staining techniques to visualize collagen deposition in cardiac tissue sections, we have developed a Fourier transform infrared imaging spectroscopy (FT-IRIS) methodology for collagen assessment. The infrared absorbance band centered at 1338 cm(-1), which arises from collagen amino acid side chain vibrations, was used to map collagen deposition across heart tissue sections of a rat model of myocardial infarction, and was compared to conventional staining techniques. Comparison of the size of the collagen scar in heart tissue sections as measured with this methodology and that of trichrome staining showed a strong correlation (R=0.93). A Pearson correlation model between local intensity values in FT-IRIS and immuno-histochemical staining of collagen type I also showed a strong correlation (R=0.86). We demonstrate that FT-IRIS methodology can be utilized to visualize cardiac collagen deposition. In addition, given that vibrational spectroscopic data on proteins reflect molecular features, it also has the potential to provide additional information about the molecular structure of cardiac extracellular matrix proteins and their alterations.


Assuntos
Algoritmos , Colágeno/análise , Infarto do Miocárdio/metabolismo , Miocárdio/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Animais , Biomarcadores/análise , Masculino , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Expert Opin Drug Deliv ; 7(10): 1159-73, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20738211

RESUMO

IMPORTANCE OF THE FIELD: Significant improvements in breast cancer treatments have resulted in a significant decrease in mortality. However, current breast cancer therapies, for example, chemotherapy, often result in high toxicity and nonspecific side effects. Other treatments, such as hormonal and antiangiogenic therapies, often have low treatment efficacy if used alone. In addition, acquired drug resistance decreases further the treatment efficacy of these therapies. Intra-tumor heterogeneity of the tumor tissue may be a major reason for the low treatment efficacy and the development of chemoresistance. Therefore, targeted multi-drug therapy is a valuable option for addressing the multiple mechanisms that may be responsible for reduced efficacy of current therapies. AREAS COVERED IN THIS REVIEW: In this article, different classes of drugs for treating breast cancer, the possible reasons for the drug resistance in breast cancer, as well as different targeted drug delivery systems are summarized. The current targeting strategies used in cancer treatment are discussed. WHAT THE READER WILL GAIN: This article considers the current state of breast cancer therapy and the possible future directions in targeted multi-drug delivery for treating breast cancer. TAKE HOME MESSAGE: A better understanding of tumor biology and physiological responses to nanoparticles, as well as advanced nanoparticle design, are needed to improve the therapeutic outcomes for treating breast cancer using nanoparticle-based targeted drug delivery systems. Moreover, selective delivery of multi-drugs to tumor tissue using targeted drug delivery systems may reduce systemic toxicity further, overcome drug resistances, and improve therapeutic efficacy in treating breast cancer.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias da Mama/tratamento farmacológico , Combinação de Medicamentos , Sistemas de Liberação de Medicamentos , Terapia de Alvo Molecular , Nanopartículas/administração & dosagem , Antineoplásicos/uso terapêutico , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Portadores de Fármacos/uso terapêutico , Desenho de Fármacos , Resistencia a Medicamentos Antineoplásicos , Feminino , Humanos , Nanopartículas/química , Nanopartículas/uso terapêutico , Tamanho da Partícula , Resultado do Tratamento
6.
FASEB J ; 23(10): 3361-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19535683

RESUMO

Recent attempts at rebuilding the myocardium using stem cells have yielded disappointing results. The lack of a supporting vasculature may, in part, explain these disappointing findings. However, concerns over possible side effects have hampered attempts at revascularizing the infarcted myocardium using systemic delivery of proangiogenic compounds. In this study, we develop the technology to enhance the morphology and function of postinfarct neovasculature. Previously, we have shown that the up-regulated expression of endothelial cell adhesion molecules in the myocardial infarction (MI) region provides a potential avenue for selectively targeting drugs to infarcted tissue. After treatment with anti-P-selectin-conjugated liposomes containing vascular endothelial growth factor (VEGF), changes in cardiac function and vasculature post-MI were quantified in a rat MI model. Targeted delivery of VEGF to post-MI tissue resulted in significant increase in fractional shortening and improved systolic function. These functional improvements were accompanied by a 21% increase in the number of anatomical vessels and a 74% increase in the number of perfused vessels in the MI region of treated animals. No significant improvements in cardiac function were observed in untreated, systemic VEGF-treated, nontargeted liposome-treated, or blank immunoliposome-treated animals. Targeted delivery of low doses of proangiogenic compounds to post-MI tissue results in significant improvements in cardiac function and vascular structure.


Assuntos
Sistemas de Liberação de Medicamentos , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/fisiopatologia , Miocárdio , Neovascularização Fisiológica/efeitos dos fármacos , Fator A de Crescimento do Endotélio Vascular/administração & dosagem , Animais , Coração/efeitos dos fármacos , Coração/fisiopatologia , Lipossomos , Masculino , Selectina-P/imunologia , Ratos , Ratos Sprague-Dawley
7.
Biomed Microdevices ; 11(5): 1051-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19452279

RESUMO

Existing microfluidic devices, e.g. parallel plate flow chambers, do not accurately depict the geometry of microvascular networks in vivo. We have developed a synthetic microvascular network (SMN) on a polydimethalsiloxane (PDMS) chip that can serve as an in vitro model of the bifurcations, tortuosities, and cross-sectional changes found in microvascular networks in vivo. Microvascular networks from a cremaster muscle were mapped using a modified Geographical Information System, and then used to manufacture the SMNs on a PDMS chip. The networks were cultured with bovine aortic endothelial cells (BAEC), which reached confluency 3-4 days after seeding. Propidium iodide staining indicated viable and healthy cells showing normal behavior in these networks. Anti-ICAM-1 conjugated 2-mum microspheres adhered to BAEC cells activated with TNF-alpha in significantly larger numbers compared to control IgG conjugated microspheres. This preferential adhesion suggests that cultured cells retain an intact cytokine response in the SMN. This microfluidic system can provide novel insight into characterization of drug delivery particles and dynamic flow conditions in microvascular networks.


Assuntos
Biomimética/métodos , Vasos Sanguíneos/citologia , Técnicas Analíticas Microfluídicas/métodos , Animais , Bovinos , Sobrevivência Celular/efeitos dos fármacos , Cricetinae , Dimetilpolisiloxanos/química , Células Endoteliais/citologia , Células Endoteliais/efeitos dos fármacos , Humanos , Músculos/irrigação sanguínea , Fator de Necrose Tumoral alfa/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA